Spectroscopic measurements of hydrogen ion temperature during divertor recombination
We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord inte...
Gespeichert in:
Veröffentlicht in: | Review of Scientific Instruments 1999-01, Vol.70 (1), p.347-350 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 350 |
---|---|
container_issue | 1 |
container_start_page | 347 |
container_title | Review of Scientific Instruments |
container_volume | 70 |
creator | Stotler, D. P. Skinner, C. H. Karney, C. F. F. |
description | We explore the possibility of using the neutral
H
α
spectral line profile to measure the ion temperature,
T
i
,
in a recombining plasma. Since the
H
α
emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened
H
α
spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density,
n
e
,
and
T
i
consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest
n
e
variation. General measurements of the ion temperature by
H
α
spectroscopy appear feasible within the context of a model for the entire divertor plasma. |
doi_str_mv | 10.1063/1.1149431 |
format | Article |
fullrecord | <record><control><sourceid>scitation_osti_</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1149431</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</originalsourceid><addsrcrecordid>eNqd0M1KAzEUBeAgCtbqwjeIS4WpuZOfmVlKsSoUXFjXIZNk2ogzGZK00Lc3tQX33s3dfBw4B6FbIDMggj7CDIA1jMIZmgCpm6ISJT1HE0IoK0TF6kt0FeMXyccBJmj1MVqdgo_aj07j3qq4Dba3Q4rYd3izN8Gv7YCdH3Cy_WiDShlgsw1uWGPjdjYkH3Cw2vetG1TK8hpddOo72pvTn6LPxfNq_los31_e5k_LQtOSpsK0FaVlBQ3jBmpSCV7bkrba8IYyoY2irBM1tEpxAUw0SpWKM1Ipw6zuTE2n6O6Y62NyMmqXrN5oPwy5kqRlzVmZzf3R6FwyBtvJMbhehb0EIg-TSZCnybJ9ONpD1G-T_-GdD39QjqajP2TAe24</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</creator><creatorcontrib>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</creatorcontrib><description>We explore the possibility of using the neutral
H
α
spectral line profile to measure the ion temperature,
T
i
,
in a recombining plasma. Since the
H
α
emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened
H
α
spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density,
n
e
,
and
T
i
consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest
n
e
variation. General measurements of the ion temperature by
H
α
spectroscopy appear feasible within the context of a model for the entire divertor plasma.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1149431</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>70 PLASMA PHYSICS AND FUSION ; DIVERTORS ; DOPPLER EFFECT ; ELECTRON DENSITY ; HYDROGEN ; HYDROGEN IONS ; ION TEMPERATURE ; LINE WIDTHS ; PLASMA DIAGNOSTICS ; RECOMBINATION ; SPECTROSCOPY ; STARK EFFECT ; TEMPERATURE MEASUREMENT ; VISIBLE SPECTRA</subject><ispartof>Review of Scientific Instruments, 1999-01, Vol.70 (1), p.347-350</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</citedby><cites>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1149431$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,885,1559,4512,23930,23931,25140,27924,27925,76384,76390</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/328542$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Stotler, D. P.</creatorcontrib><creatorcontrib>Skinner, C. H.</creatorcontrib><creatorcontrib>Karney, C. F. F.</creatorcontrib><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><title>Review of Scientific Instruments</title><description>We explore the possibility of using the neutral
H
α
spectral line profile to measure the ion temperature,
T
i
,
in a recombining plasma. Since the
H
α
emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened
H
α
spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density,
n
e
,
and
T
i
consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest
n
e
variation. General measurements of the ion temperature by
H
α
spectroscopy appear feasible within the context of a model for the entire divertor plasma.</description><subject>70 PLASMA PHYSICS AND FUSION</subject><subject>DIVERTORS</subject><subject>DOPPLER EFFECT</subject><subject>ELECTRON DENSITY</subject><subject>HYDROGEN</subject><subject>HYDROGEN IONS</subject><subject>ION TEMPERATURE</subject><subject>LINE WIDTHS</subject><subject>PLASMA DIAGNOSTICS</subject><subject>RECOMBINATION</subject><subject>SPECTROSCOPY</subject><subject>STARK EFFECT</subject><subject>TEMPERATURE MEASUREMENT</subject><subject>VISIBLE SPECTRA</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqd0M1KAzEUBeAgCtbqwjeIS4WpuZOfmVlKsSoUXFjXIZNk2ogzGZK00Lc3tQX33s3dfBw4B6FbIDMggj7CDIA1jMIZmgCpm6ISJT1HE0IoK0TF6kt0FeMXyccBJmj1MVqdgo_aj07j3qq4Dba3Q4rYd3izN8Gv7YCdH3Cy_WiDShlgsw1uWGPjdjYkH3Cw2vetG1TK8hpddOo72pvTn6LPxfNq_los31_e5k_LQtOSpsK0FaVlBQ3jBmpSCV7bkrba8IYyoY2irBM1tEpxAUw0SpWKM1Ipw6zuTE2n6O6Y62NyMmqXrN5oPwy5kqRlzVmZzf3R6FwyBtvJMbhehb0EIg-TSZCnybJ9ONpD1G-T_-GdD39QjqajP2TAe24</recordid><startdate>199901</startdate><enddate>199901</enddate><creator>Stotler, D. P.</creator><creator>Skinner, C. H.</creator><creator>Karney, C. F. F.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>199901</creationdate><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><author>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>70 PLASMA PHYSICS AND FUSION</topic><topic>DIVERTORS</topic><topic>DOPPLER EFFECT</topic><topic>ELECTRON DENSITY</topic><topic>HYDROGEN</topic><topic>HYDROGEN IONS</topic><topic>ION TEMPERATURE</topic><topic>LINE WIDTHS</topic><topic>PLASMA DIAGNOSTICS</topic><topic>RECOMBINATION</topic><topic>SPECTROSCOPY</topic><topic>STARK EFFECT</topic><topic>TEMPERATURE MEASUREMENT</topic><topic>VISIBLE SPECTRA</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stotler, D. P.</creatorcontrib><creatorcontrib>Skinner, C. H.</creatorcontrib><creatorcontrib>Karney, C. F. F.</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stotler, D. P.</au><au>Skinner, C. H.</au><au>Karney, C. F. F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1999-01</date><risdate>1999</risdate><volume>70</volume><issue>1</issue><spage>347</spage><epage>350</epage><pages>347-350</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>We explore the possibility of using the neutral
H
α
spectral line profile to measure the ion temperature,
T
i
,
in a recombining plasma. Since the
H
α
emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened
H
α
spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density,
n
e
,
and
T
i
consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest
n
e
variation. General measurements of the ion temperature by
H
α
spectroscopy appear feasible within the context of a model for the entire divertor plasma.</abstract><cop>United States</cop><doi>10.1063/1.1149431</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0034-6748 |
ispartof | Review of Scientific Instruments, 1999-01, Vol.70 (1), p.347-350 |
issn | 0034-6748 1089-7623 |
language | eng |
recordid | cdi_crossref_primary_10_1063_1_1149431 |
source | AIP Journals Complete; AIP Digital Archive |
subjects | 70 PLASMA PHYSICS AND FUSION DIVERTORS DOPPLER EFFECT ELECTRON DENSITY HYDROGEN HYDROGEN IONS ION TEMPERATURE LINE WIDTHS PLASMA DIAGNOSTICS RECOMBINATION SPECTROSCOPY STARK EFFECT TEMPERATURE MEASUREMENT VISIBLE SPECTRA |
title | Spectroscopic measurements of hydrogen ion temperature during divertor recombination |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T14%3A29%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Spectroscopic%20measurements%20of%20hydrogen%20ion%20temperature%20during%20divertor%20recombination&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Stotler,%20D.%20P.&rft.date=1999-01&rft.volume=70&rft.issue=1&rft.spage=347&rft.epage=350&rft.pages=347-350&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1149431&rft_dat=%3Cscitation_osti_%3Ersi%3C/scitation_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |