Spectroscopic measurements of hydrogen ion temperature during divertor recombination

We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord inte...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of Scientific Instruments 1999-01, Vol.70 (1), p.347-350
Hauptverfasser: Stotler, D. P., Skinner, C. H., Karney, C. F. F.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 350
container_issue 1
container_start_page 347
container_title Review of Scientific Instruments
container_volume 70
creator Stotler, D. P.
Skinner, C. H.
Karney, C. F. F.
description We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened H α spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density, n e , and T i consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest n e variation. General measurements of the ion temperature by H α spectroscopy appear feasible within the context of a model for the entire divertor plasma.
doi_str_mv 10.1063/1.1149431
format Article
fullrecord <record><control><sourceid>scitation_osti_</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1149431</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</originalsourceid><addsrcrecordid>eNqd0M1KAzEUBeAgCtbqwjeIS4WpuZOfmVlKsSoUXFjXIZNk2ogzGZK00Lc3tQX33s3dfBw4B6FbIDMggj7CDIA1jMIZmgCpm6ISJT1HE0IoK0TF6kt0FeMXyccBJmj1MVqdgo_aj07j3qq4Dba3Q4rYd3izN8Gv7YCdH3Cy_WiDShlgsw1uWGPjdjYkH3Cw2vetG1TK8hpddOo72pvTn6LPxfNq_los31_e5k_LQtOSpsK0FaVlBQ3jBmpSCV7bkrba8IYyoY2irBM1tEpxAUw0SpWKM1Ipw6zuTE2n6O6Y62NyMmqXrN5oPwy5kqRlzVmZzf3R6FwyBtvJMbhehb0EIg-TSZCnybJ9ONpD1G-T_-GdD39QjqajP2TAe24</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><source>AIP Journals Complete</source><source>AIP Digital Archive</source><creator>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</creator><creatorcontrib>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</creatorcontrib><description>We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened H α spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density, n e , and T i consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest n e variation. General measurements of the ion temperature by H α spectroscopy appear feasible within the context of a model for the entire divertor plasma.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1149431</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><publisher>United States</publisher><subject>70 PLASMA PHYSICS AND FUSION ; DIVERTORS ; DOPPLER EFFECT ; ELECTRON DENSITY ; HYDROGEN ; HYDROGEN IONS ; ION TEMPERATURE ; LINE WIDTHS ; PLASMA DIAGNOSTICS ; RECOMBINATION ; SPECTROSCOPY ; STARK EFFECT ; TEMPERATURE MEASUREMENT ; VISIBLE SPECTRA</subject><ispartof>Review of Scientific Instruments, 1999-01, Vol.70 (1), p.347-350</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</citedby><cites>FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1149431$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>309,310,314,780,784,789,790,794,885,1559,4512,23930,23931,25140,27924,27925,76384,76390</link.rule.ids><backlink>$$Uhttps://www.osti.gov/biblio/328542$$D View this record in Osti.gov$$Hfree_for_read</backlink></links><search><creatorcontrib>Stotler, D. P.</creatorcontrib><creatorcontrib>Skinner, C. H.</creatorcontrib><creatorcontrib>Karney, C. F. F.</creatorcontrib><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><title>Review of Scientific Instruments</title><description>We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened H α spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density, n e , and T i consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest n e variation. General measurements of the ion temperature by H α spectroscopy appear feasible within the context of a model for the entire divertor plasma.</description><subject>70 PLASMA PHYSICS AND FUSION</subject><subject>DIVERTORS</subject><subject>DOPPLER EFFECT</subject><subject>ELECTRON DENSITY</subject><subject>HYDROGEN</subject><subject>HYDROGEN IONS</subject><subject>ION TEMPERATURE</subject><subject>LINE WIDTHS</subject><subject>PLASMA DIAGNOSTICS</subject><subject>RECOMBINATION</subject><subject>SPECTROSCOPY</subject><subject>STARK EFFECT</subject><subject>TEMPERATURE MEASUREMENT</subject><subject>VISIBLE SPECTRA</subject><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1999</creationdate><recordtype>article</recordtype><recordid>eNqd0M1KAzEUBeAgCtbqwjeIS4WpuZOfmVlKsSoUXFjXIZNk2ogzGZK00Lc3tQX33s3dfBw4B6FbIDMggj7CDIA1jMIZmgCpm6ISJT1HE0IoK0TF6kt0FeMXyccBJmj1MVqdgo_aj07j3qq4Dba3Q4rYd3izN8Gv7YCdH3Cy_WiDShlgsw1uWGPjdjYkH3Cw2vetG1TK8hpddOo72pvTn6LPxfNq_los31_e5k_LQtOSpsK0FaVlBQ3jBmpSCV7bkrba8IYyoY2irBM1tEpxAUw0SpWKM1Ipw6zuTE2n6O6Y62NyMmqXrN5oPwy5kqRlzVmZzf3R6FwyBtvJMbhehb0EIg-TSZCnybJ9ONpD1G-T_-GdD39QjqajP2TAe24</recordid><startdate>199901</startdate><enddate>199901</enddate><creator>Stotler, D. P.</creator><creator>Skinner, C. H.</creator><creator>Karney, C. F. F.</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>OTOTI</scope></search><sort><creationdate>199901</creationdate><title>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</title><author>Stotler, D. P. ; Skinner, C. H. ; Karney, C. F. F.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c323t-db733271945d1807658e23bcd59346cda34f681baa561469aa2a5407ad4ecfd83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1999</creationdate><topic>70 PLASMA PHYSICS AND FUSION</topic><topic>DIVERTORS</topic><topic>DOPPLER EFFECT</topic><topic>ELECTRON DENSITY</topic><topic>HYDROGEN</topic><topic>HYDROGEN IONS</topic><topic>ION TEMPERATURE</topic><topic>LINE WIDTHS</topic><topic>PLASMA DIAGNOSTICS</topic><topic>RECOMBINATION</topic><topic>SPECTROSCOPY</topic><topic>STARK EFFECT</topic><topic>TEMPERATURE MEASUREMENT</topic><topic>VISIBLE SPECTRA</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Stotler, D. P.</creatorcontrib><creatorcontrib>Skinner, C. H.</creatorcontrib><creatorcontrib>Karney, C. F. F.</creatorcontrib><collection>CrossRef</collection><collection>OSTI.GOV</collection><jtitle>Review of Scientific Instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Stotler, D. P.</au><au>Skinner, C. H.</au><au>Karney, C. F. F.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Spectroscopic measurements of hydrogen ion temperature during divertor recombination</atitle><jtitle>Review of Scientific Instruments</jtitle><date>1999-01</date><risdate>1999</risdate><volume>70</volume><issue>1</issue><spage>347</spage><epage>350</epage><pages>347-350</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>We explore the possibility of using the neutral H α spectral line profile to measure the ion temperature, T i , in a recombining plasma. Since the H α emissions due to recombination are larger than those due to other mechanisms, interference from nonrecombining regions contributing to the chord integrated data is insignificant. A Doppler and Stark broadened H α spectrum is simulated by the DEGAS 2 neutral transport code using assumed plasma conditions. The application of a simple fitting procedure to this spectrum yields an electron density, n e , and T i consistent with the assumed plasma parameters if the spectrum is dominated by recombination from a region of modest n e variation. General measurements of the ion temperature by H α spectroscopy appear feasible within the context of a model for the entire divertor plasma.</abstract><cop>United States</cop><doi>10.1063/1.1149431</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of Scientific Instruments, 1999-01, Vol.70 (1), p.347-350
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1149431
source AIP Journals Complete; AIP Digital Archive
subjects 70 PLASMA PHYSICS AND FUSION
DIVERTORS
DOPPLER EFFECT
ELECTRON DENSITY
HYDROGEN
HYDROGEN IONS
ION TEMPERATURE
LINE WIDTHS
PLASMA DIAGNOSTICS
RECOMBINATION
SPECTROSCOPY
STARK EFFECT
TEMPERATURE MEASUREMENT
VISIBLE SPECTRA
title Spectroscopic measurements of hydrogen ion temperature during divertor recombination
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T14%3A29%3A58IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_osti_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Spectroscopic%20measurements%20of%20hydrogen%20ion%20temperature%20during%20divertor%20recombination&rft.jtitle=Review%20of%20Scientific%20Instruments&rft.au=Stotler,%20D.%20P.&rft.date=1999-01&rft.volume=70&rft.issue=1&rft.spage=347&rft.epage=350&rft.pages=347-350&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1149431&rft_dat=%3Cscitation_osti_%3Ersi%3C/scitation_osti_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true