A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples

A multipurpose scanning near field optical microscope (SNOM) operating at ambient pressure is described with the aim of characterizing the inner parts of biological molecules and any semiconductor or metal microstructure. Therefore, in addition to the requirements of reliability and mechanical stabi...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Review of scientific instruments 1998-09, Vol.69 (9), p.3240-3244
Hauptverfasser: Cricenti, A., Generosi, R., Barchesi, C., Luce, M., Rinaldi, M.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 3244
container_issue 9
container_start_page 3240
container_title Review of scientific instruments
container_volume 69
creator Cricenti, A.
Generosi, R.
Barchesi, C.
Luce, M.
Rinaldi, M.
description A multipurpose scanning near field optical microscope (SNOM) operating at ambient pressure is described with the aim of characterizing the inner parts of biological molecules and any semiconductor or metal microstructure. Therefore, in addition to the requirements of reliability and mechanical stability we have carefully considered analyzing a sample with all available geometries for input/output of photons, in order to get as much information as possible. The SNOM unit consists of two separable cylindrical supports; the lower one contains the sample holder mounted on top of a piezoelectric scanner which is contained in a motor controlled x-y-z stage. A piezo-modulated stretched optical fiber with a few tens of nanometer pinhole and a shear-force apparatus mounted inside the top cylinder allow for topography measurements. The reflectivity of the sample can be measured by applying different methods: the sample can be illuminated on top by an external source, as well as by the optical fiber used for the detection of the reflectivity signal. An aperture in the lower cylinder allows for illumination of the sample on the back: in this case the fiber collects the evanescent wave induced at the top of the sample. Another aperture in the lower cylinder allows measurement of the reflected light which includes a contribution due to the interaction with the fiber. Also photocurrent experiments can be easily performed by illuminating the sample with the fiber and detecting the transmitted signal using a current–voltage converter mounted inside the top cylinder. A video-camera that can reach 170 enlargements is mounted on the top cylinder for positioning the fiber on particular regions of the sample. Reflectivity and photocurrent measurements have been performed on uncoated neurons, CsI compound, Au/GaAs, and PtSi/Si systems, reaching a resolution well below the diffraction limit.
doi_str_mv 10.1063/1.1149089
format Article
fullrecord <record><control><sourceid>scitation_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1063_1_1149089</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>rsi</sourcerecordid><originalsourceid>FETCH-LOGICAL-c363t-fa23f767f24a472fb1d64f748797b3f0f7740dd5fff65f1340c99cbd48cf9fdb3</originalsourceid><addsrcrecordid>eNp90MtKAzEUBuAgCtbLwjfIVmFqMkknHXeleIOCILoeMklOjUyTkGQKBR_e6QVdCJ7Nv_n4OecgdEXJmJKK3dIxpbwm0_oIjegQhahKdoxGhDBeVIJPT9FZSp9kmAmlI_Q1w6u-yzb0MfhkcFLSOeuW2BkZC7Cm09iHbJXs8Mqq6JPywdzhVwOdUdmubd5g6TQOHz571cdoXMbe4WQG7p3uVfZxJ1rrO7_cNSW5Cp1JF-gEZJfM5SHP0fvD_dv8qVi8PD7PZ4tCsYrlAmTJQFQCSi65KKGluuIw3CJq0TIgIAQnWk8AoJoAZZyoulat5lMFNeiWnaPrfe92_xQNNCHalYybhpJm-7aGNoe3DfZmb5OyWWbr3Q9e-_gLm6DhP_y3-RsCBn-3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples</title><source>AIP Digital Archive</source><creator>Cricenti, A. ; Generosi, R. ; Barchesi, C. ; Luce, M. ; Rinaldi, M.</creator><creatorcontrib>Cricenti, A. ; Generosi, R. ; Barchesi, C. ; Luce, M. ; Rinaldi, M.</creatorcontrib><description>A multipurpose scanning near field optical microscope (SNOM) operating at ambient pressure is described with the aim of characterizing the inner parts of biological molecules and any semiconductor or metal microstructure. Therefore, in addition to the requirements of reliability and mechanical stability we have carefully considered analyzing a sample with all available geometries for input/output of photons, in order to get as much information as possible. The SNOM unit consists of two separable cylindrical supports; the lower one contains the sample holder mounted on top of a piezoelectric scanner which is contained in a motor controlled x-y-z stage. A piezo-modulated stretched optical fiber with a few tens of nanometer pinhole and a shear-force apparatus mounted inside the top cylinder allow for topography measurements. The reflectivity of the sample can be measured by applying different methods: the sample can be illuminated on top by an external source, as well as by the optical fiber used for the detection of the reflectivity signal. An aperture in the lower cylinder allows for illumination of the sample on the back: in this case the fiber collects the evanescent wave induced at the top of the sample. Another aperture in the lower cylinder allows measurement of the reflected light which includes a contribution due to the interaction with the fiber. Also photocurrent experiments can be easily performed by illuminating the sample with the fiber and detecting the transmitted signal using a current–voltage converter mounted inside the top cylinder. A video-camera that can reach 170 enlargements is mounted on the top cylinder for positioning the fiber on particular regions of the sample. Reflectivity and photocurrent measurements have been performed on uncoated neurons, CsI compound, Au/GaAs, and PtSi/Si systems, reaching a resolution well below the diffraction limit.</description><identifier>ISSN: 0034-6748</identifier><identifier>EISSN: 1089-7623</identifier><identifier>DOI: 10.1063/1.1149089</identifier><identifier>CODEN: RSINAK</identifier><language>eng</language><ispartof>Review of scientific instruments, 1998-09, Vol.69 (9), p.3240-3244</ispartof><rights>American Institute of Physics</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c363t-fa23f767f24a472fb1d64f748797b3f0f7740dd5fff65f1340c99cbd48cf9fdb3</citedby><cites>FETCH-LOGICAL-c363t-fa23f767f24a472fb1d64f748797b3f0f7740dd5fff65f1340c99cbd48cf9fdb3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://pubs.aip.org/rsi/article-lookup/doi/10.1063/1.1149089$$EHTML$$P50$$Gscitation$$H</linktohtml><link.rule.ids>314,778,782,1556,27907,27908,76141</link.rule.ids></links><search><creatorcontrib>Cricenti, A.</creatorcontrib><creatorcontrib>Generosi, R.</creatorcontrib><creatorcontrib>Barchesi, C.</creatorcontrib><creatorcontrib>Luce, M.</creatorcontrib><creatorcontrib>Rinaldi, M.</creatorcontrib><title>A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples</title><title>Review of scientific instruments</title><description>A multipurpose scanning near field optical microscope (SNOM) operating at ambient pressure is described with the aim of characterizing the inner parts of biological molecules and any semiconductor or metal microstructure. Therefore, in addition to the requirements of reliability and mechanical stability we have carefully considered analyzing a sample with all available geometries for input/output of photons, in order to get as much information as possible. The SNOM unit consists of two separable cylindrical supports; the lower one contains the sample holder mounted on top of a piezoelectric scanner which is contained in a motor controlled x-y-z stage. A piezo-modulated stretched optical fiber with a few tens of nanometer pinhole and a shear-force apparatus mounted inside the top cylinder allow for topography measurements. The reflectivity of the sample can be measured by applying different methods: the sample can be illuminated on top by an external source, as well as by the optical fiber used for the detection of the reflectivity signal. An aperture in the lower cylinder allows for illumination of the sample on the back: in this case the fiber collects the evanescent wave induced at the top of the sample. Another aperture in the lower cylinder allows measurement of the reflected light which includes a contribution due to the interaction with the fiber. Also photocurrent experiments can be easily performed by illuminating the sample with the fiber and detecting the transmitted signal using a current–voltage converter mounted inside the top cylinder. A video-camera that can reach 170 enlargements is mounted on the top cylinder for positioning the fiber on particular regions of the sample. Reflectivity and photocurrent measurements have been performed on uncoated neurons, CsI compound, Au/GaAs, and PtSi/Si systems, reaching a resolution well below the diffraction limit.</description><issn>0034-6748</issn><issn>1089-7623</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNp90MtKAzEUBuAgCtbLwjfIVmFqMkknHXeleIOCILoeMklOjUyTkGQKBR_e6QVdCJ7Nv_n4OecgdEXJmJKK3dIxpbwm0_oIjegQhahKdoxGhDBeVIJPT9FZSp9kmAmlI_Q1w6u-yzb0MfhkcFLSOeuW2BkZC7Cm09iHbJXs8Mqq6JPywdzhVwOdUdmubd5g6TQOHz571cdoXMbe4WQG7p3uVfZxJ1rrO7_cNSW5Cp1JF-gEZJfM5SHP0fvD_dv8qVi8PD7PZ4tCsYrlAmTJQFQCSi65KKGluuIw3CJq0TIgIAQnWk8AoJoAZZyoulat5lMFNeiWnaPrfe92_xQNNCHalYybhpJm-7aGNoe3DfZmb5OyWWbr3Q9e-_gLm6DhP_y3-RsCBn-3</recordid><startdate>19980901</startdate><enddate>19980901</enddate><creator>Cricenti, A.</creator><creator>Generosi, R.</creator><creator>Barchesi, C.</creator><creator>Luce, M.</creator><creator>Rinaldi, M.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980901</creationdate><title>A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples</title><author>Cricenti, A. ; Generosi, R. ; Barchesi, C. ; Luce, M. ; Rinaldi, M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c363t-fa23f767f24a472fb1d64f748797b3f0f7740dd5fff65f1340c99cbd48cf9fdb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Cricenti, A.</creatorcontrib><creatorcontrib>Generosi, R.</creatorcontrib><creatorcontrib>Barchesi, C.</creatorcontrib><creatorcontrib>Luce, M.</creatorcontrib><creatorcontrib>Rinaldi, M.</creatorcontrib><collection>CrossRef</collection><jtitle>Review of scientific instruments</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Cricenti, A.</au><au>Generosi, R.</au><au>Barchesi, C.</au><au>Luce, M.</au><au>Rinaldi, M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples</atitle><jtitle>Review of scientific instruments</jtitle><date>1998-09-01</date><risdate>1998</risdate><volume>69</volume><issue>9</issue><spage>3240</spage><epage>3244</epage><pages>3240-3244</pages><issn>0034-6748</issn><eissn>1089-7623</eissn><coden>RSINAK</coden><abstract>A multipurpose scanning near field optical microscope (SNOM) operating at ambient pressure is described with the aim of characterizing the inner parts of biological molecules and any semiconductor or metal microstructure. Therefore, in addition to the requirements of reliability and mechanical stability we have carefully considered analyzing a sample with all available geometries for input/output of photons, in order to get as much information as possible. The SNOM unit consists of two separable cylindrical supports; the lower one contains the sample holder mounted on top of a piezoelectric scanner which is contained in a motor controlled x-y-z stage. A piezo-modulated stretched optical fiber with a few tens of nanometer pinhole and a shear-force apparatus mounted inside the top cylinder allow for topography measurements. The reflectivity of the sample can be measured by applying different methods: the sample can be illuminated on top by an external source, as well as by the optical fiber used for the detection of the reflectivity signal. An aperture in the lower cylinder allows for illumination of the sample on the back: in this case the fiber collects the evanescent wave induced at the top of the sample. Another aperture in the lower cylinder allows measurement of the reflected light which includes a contribution due to the interaction with the fiber. Also photocurrent experiments can be easily performed by illuminating the sample with the fiber and detecting the transmitted signal using a current–voltage converter mounted inside the top cylinder. A video-camera that can reach 170 enlargements is mounted on the top cylinder for positioning the fiber on particular regions of the sample. Reflectivity and photocurrent measurements have been performed on uncoated neurons, CsI compound, Au/GaAs, and PtSi/Si systems, reaching a resolution well below the diffraction limit.</abstract><doi>10.1063/1.1149089</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0034-6748
ispartof Review of scientific instruments, 1998-09, Vol.69 (9), p.3240-3244
issn 0034-6748
1089-7623
language eng
recordid cdi_crossref_primary_10_1063_1_1149089
source AIP Digital Archive
title A multipurpose scanning near-field optical microscope: Reflectivity and photocurrent on semiconductor and biological samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-16T09%3A08%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-scitation_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20multipurpose%20scanning%20near-field%20optical%20microscope:%20Reflectivity%20and%20photocurrent%20on%20semiconductor%20and%20biological%20samples&rft.jtitle=Review%20of%20scientific%20instruments&rft.au=Cricenti,%20A.&rft.date=1998-09-01&rft.volume=69&rft.issue=9&rft.spage=3240&rft.epage=3244&rft.pages=3240-3244&rft.issn=0034-6748&rft.eissn=1089-7623&rft.coden=RSINAK&rft_id=info:doi/10.1063/1.1149089&rft_dat=%3Cscitation_cross%3Ersi%3C/scitation_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true