A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion

Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that pr...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The Journal of extra-corporeal technology 2020-12, Vol.52 (4), p.303-313
Hauptverfasser: Duignan, Thomas, Guariento, Alvise, Doulamis, Ilias P, Kido, Takashi, Regan, William L, Saeed, Mossab, Hoganson, David M, Emani, Sitaram M, Del Nido, Pedro J, McCully, James D, Matte, Gregory S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 313
container_issue 4
container_start_page 303
container_title The Journal of extra-corporeal technology
container_volume 52
creator Duignan, Thomas
Guariento, Alvise
Doulamis, Ilias P
Kido, Takashi
Regan, William L
Saeed, Mossab
Hoganson, David M
Emani, Sitaram M
Del Nido, Pedro J
McCully, James D
Matte, Gregory S
description Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.
doi_str_mv 10.1051/ject/202052303
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1051_ject_202052303</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>33343033</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2173-d7df2096fb242c5465792ce101cb7ecd592b4009bde76b08287e75910681809b3</originalsourceid><addsrcrecordid>eNo9kF1rwjAUhsPYmM7tdpcjf6B6krRJcymic6BMcLsubZK6SD8kaWH990bcvDovL897Lh6EXglMCSRkdjSqm1GgkFAG7A6NqeQySiWHezQGoDQKWDpCT94fATgBRh7RiDEWB5yNkZ3jbV91Ntq22uD94DtT47J1eDu0Knfa5hVe9Y3qbNuEmDca734Gb9uqPVgVmrn3xvvaNB3WvbPNAS9_8d52PV6b3HV4Z1zZB755Rg9lXnnz8ncn6Hu1_Fqso83n-8divokUJYJFWuiSguRlQWOqkpgnQlJlCBBVCKN0ImkRA8hCG8ELSGkqjEgkAZ6SNNRsgqbXv8q13jtTZidn69wNGYHs4iy7OMtuzsLg7To49UVt9A3_l8TO7exn3w</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion</title><source>MEDLINE</source><source>EZB-FREE-00999 freely available EZB journals</source><source>PubMed Central</source><creator>Duignan, Thomas ; Guariento, Alvise ; Doulamis, Ilias P ; Kido, Takashi ; Regan, William L ; Saeed, Mossab ; Hoganson, David M ; Emani, Sitaram M ; Del Nido, Pedro J ; McCully, James D ; Matte, Gregory S</creator><creatorcontrib>Duignan, Thomas ; Guariento, Alvise ; Doulamis, Ilias P ; Kido, Takashi ; Regan, William L ; Saeed, Mossab ; Hoganson, David M ; Emani, Sitaram M ; Del Nido, Pedro J ; McCully, James D ; Matte, Gregory S</creatorcontrib><description>Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.</description><identifier>ISSN: 0022-1058</identifier><identifier>EISSN: 2969-8960</identifier><identifier>DOI: 10.1051/ject/202052303</identifier><identifier>PMID: 33343033</identifier><language>eng</language><publisher>United States</publisher><subject>Animals ; Female ; Heart ; Heart Transplantation ; Humans ; Myocardium ; Perfusion ; Swine ; Tissue Donors</subject><ispartof>The Journal of extra-corporeal technology, 2020-12, Vol.52 (4), p.303-313</ispartof><rights>Copyright 2020 AMSECT.</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2173-d7df2096fb242c5465792ce101cb7ecd592b4009bde76b08287e75910681809b3</citedby><cites>FETCH-LOGICAL-c2173-d7df2096fb242c5465792ce101cb7ecd592b4009bde76b08287e75910681809b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,781,785,27928,27929</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/33343033$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Duignan, Thomas</creatorcontrib><creatorcontrib>Guariento, Alvise</creatorcontrib><creatorcontrib>Doulamis, Ilias P</creatorcontrib><creatorcontrib>Kido, Takashi</creatorcontrib><creatorcontrib>Regan, William L</creatorcontrib><creatorcontrib>Saeed, Mossab</creatorcontrib><creatorcontrib>Hoganson, David M</creatorcontrib><creatorcontrib>Emani, Sitaram M</creatorcontrib><creatorcontrib>Del Nido, Pedro J</creatorcontrib><creatorcontrib>McCully, James D</creatorcontrib><creatorcontrib>Matte, Gregory S</creatorcontrib><title>A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion</title><title>The Journal of extra-corporeal technology</title><addtitle>J Extra Corpor Technol</addtitle><description>Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.</description><subject>Animals</subject><subject>Female</subject><subject>Heart</subject><subject>Heart Transplantation</subject><subject>Humans</subject><subject>Myocardium</subject><subject>Perfusion</subject><subject>Swine</subject><subject>Tissue Donors</subject><issn>0022-1058</issn><issn>2969-8960</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNo9kF1rwjAUhsPYmM7tdpcjf6B6krRJcymic6BMcLsubZK6SD8kaWH990bcvDovL897Lh6EXglMCSRkdjSqm1GgkFAG7A6NqeQySiWHezQGoDQKWDpCT94fATgBRh7RiDEWB5yNkZ3jbV91Ntq22uD94DtT47J1eDu0Knfa5hVe9Y3qbNuEmDca734Gb9uqPVgVmrn3xvvaNB3WvbPNAS9_8d52PV6b3HV4Z1zZB755Rg9lXnnz8ncn6Hu1_Fqso83n-8divokUJYJFWuiSguRlQWOqkpgnQlJlCBBVCKN0ImkRA8hCG8ELSGkqjEgkAZ6SNNRsgqbXv8q13jtTZidn69wNGYHs4iy7OMtuzsLg7To49UVt9A3_l8TO7exn3w</recordid><startdate>202012</startdate><enddate>202012</enddate><creator>Duignan, Thomas</creator><creator>Guariento, Alvise</creator><creator>Doulamis, Ilias P</creator><creator>Kido, Takashi</creator><creator>Regan, William L</creator><creator>Saeed, Mossab</creator><creator>Hoganson, David M</creator><creator>Emani, Sitaram M</creator><creator>Del Nido, Pedro J</creator><creator>McCully, James D</creator><creator>Matte, Gregory S</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202012</creationdate><title>A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion</title><author>Duignan, Thomas ; Guariento, Alvise ; Doulamis, Ilias P ; Kido, Takashi ; Regan, William L ; Saeed, Mossab ; Hoganson, David M ; Emani, Sitaram M ; Del Nido, Pedro J ; McCully, James D ; Matte, Gregory S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2173-d7df2096fb242c5465792ce101cb7ecd592b4009bde76b08287e75910681809b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Animals</topic><topic>Female</topic><topic>Heart</topic><topic>Heart Transplantation</topic><topic>Humans</topic><topic>Myocardium</topic><topic>Perfusion</topic><topic>Swine</topic><topic>Tissue Donors</topic><toplevel>online_resources</toplevel><creatorcontrib>Duignan, Thomas</creatorcontrib><creatorcontrib>Guariento, Alvise</creatorcontrib><creatorcontrib>Doulamis, Ilias P</creatorcontrib><creatorcontrib>Kido, Takashi</creatorcontrib><creatorcontrib>Regan, William L</creatorcontrib><creatorcontrib>Saeed, Mossab</creatorcontrib><creatorcontrib>Hoganson, David M</creatorcontrib><creatorcontrib>Emani, Sitaram M</creatorcontrib><creatorcontrib>Del Nido, Pedro J</creatorcontrib><creatorcontrib>McCully, James D</creatorcontrib><creatorcontrib>Matte, Gregory S</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>The Journal of extra-corporeal technology</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Duignan, Thomas</au><au>Guariento, Alvise</au><au>Doulamis, Ilias P</au><au>Kido, Takashi</au><au>Regan, William L</au><au>Saeed, Mossab</au><au>Hoganson, David M</au><au>Emani, Sitaram M</au><au>Del Nido, Pedro J</au><au>McCully, James D</au><au>Matte, Gregory S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion</atitle><jtitle>The Journal of extra-corporeal technology</jtitle><addtitle>J Extra Corpor Technol</addtitle><date>2020-12</date><risdate>2020</risdate><volume>52</volume><issue>4</issue><spage>303</spage><epage>313</epage><pages>303-313</pages><issn>0022-1058</issn><eissn>2969-8960</eissn><abstract>Ex situ heart perfusion (ESHP) has proven to be an important and valuable step toward better preservation of donor hearts for heart transplantation. Currently, few ESHP systems allow for a convenient functional and physiological evaluation of the heart. We sought to establish a simple system that provides functional and physiological assessment of the heart during ESHP. The ESHP circuit consists of an oxygenator, a heart-lung machine, a heater-cooler unit, an anesthesia gas blender, and a collection funnel. Female Yorkshire pig hearts (n = 10) had del Nido cardioplegia (4°C) administered, excised, and attached to the perfusion system. Hearts were perfused retrogradely into the aortic root for 2 hours before converting the system to an isovolumic mode or a working mode for further 2 hours. Blood samples were analyzed to measure metabolic parameters. During the isovolumic mode (n = 5), a balloon inserted in the left ventricular (LV) cavity was inflated so that an end-diastolic pressure of 6-8 mmHg was reached. During the working mode (n = 5), perfusion in the aortic root was redirected into left atrium (LA) using a compliance chamber which maintained an LA pressure of 6-8 mmHg. Another compliance chamber was used to provide an afterload of 40-50 mmHg. Hemodynamic and metabolic conditions remained stable and consistent for a period of 4 hours of ESHP in both isovolumic mode (LV developed pressure: 101.0 ± 3.5 vs. 99.7 ± 6.8 mmHg, = .979, at 2 and 4 hours, respectively) and working mode (LV developed pressure: 91.0 ± 2.6 vs. 90.7 ± 2.5 mmHg, = .942, at 2 and 4 hours, respectively). The present study proposed a novel ESHP system that enables comprehensive functional and metabolic assessment of large mammalian hearts. This system allowed for stable myocardial function for up to 4 hours of perfusion, which would offer great potential for the development of translational therapeutic protocols to improve dysfunctional donated hearts.</abstract><cop>United States</cop><pmid>33343033</pmid><doi>10.1051/ject/202052303</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0022-1058
ispartof The Journal of extra-corporeal technology, 2020-12, Vol.52 (4), p.303-313
issn 0022-1058
2969-8960
language eng
recordid cdi_crossref_primary_10_1051_ject_202052303
source MEDLINE; EZB-FREE-00999 freely available EZB journals; PubMed Central
subjects Animals
Female
Heart
Heart Transplantation
Humans
Myocardium
Perfusion
Swine
Tissue Donors
title A Multi-Mode System for Myocardial Functional and Physiological Assessment during Ex Situ Heart Perfusion
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-16T13%3A45%3A55IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Multi-Mode%20System%20for%20Myocardial%20Functional%20and%20Physiological%20Assessment%20during%20Ex%20Situ%20Heart%20Perfusion&rft.jtitle=The%20Journal%20of%20extra-corporeal%20technology&rft.au=Duignan,%20Thomas&rft.date=2020-12&rft.volume=52&rft.issue=4&rft.spage=303&rft.epage=313&rft.pages=303-313&rft.issn=0022-1058&rft.eissn=2969-8960&rft_id=info:doi/10.1051/ject/202052303&rft_dat=%3Cpubmed_cross%3E33343033%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/33343033&rfr_iscdi=true