Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures

Pesticides are primarily used in agriculture to protect crops and extend their longevity. However, pesticide exposure has been linked to various acute and chronic health effects, raising significant environmental concerns. Current detection methods are often expensive and time-consuming, relying on...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2024-11, Vol.149 (23), p.5684-5692
Hauptverfasser: Hefner, Claire E, Aryal, Prakash, Brack, Eric, Alexander, Todd, Henry, Charles S
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 5692
container_issue 23
container_start_page 5684
container_title Analyst (London)
container_volume 149
creator Hefner, Claire E
Aryal, Prakash
Brack, Eric
Alexander, Todd
Henry, Charles S
description Pesticides are primarily used in agriculture to protect crops and extend their longevity. However, pesticide exposure has been linked to various acute and chronic health effects, raising significant environmental concerns. Current detection methods are often expensive and time-consuming, relying on complex instruments. Although enzyme-inhibition-based microfluidic paper-based analytical device (mPAD) platforms offer an easier alternative, they suffer from slow analyte transport and analyte adsorption issues in microchannels. Consequently, there is a need for a fast, simple, and cost-effective point-of-need platform for pesticide sensing. In this study, we present a rapid microfluidic platform for on-site pesticide residue detection. Unlike traditional mPAD platforms, our system transports pesticide samples through hollow capillary channels within seconds without adsorption of pesticides in the microchannels. While much research has focused on acetylcholinesterase inhibition on paper, this study is the first to introduce a tyrosinase inhibition-based assay on a paper platform for pesticide detection. Ziram, a representative dithiocarbamate pesticide, was detected using a colorimetric enzymatic inhibition assay. A limit of detection (LoD) of 1.5 ppm was obtained. In this study, we optimized the fast-flow device, assessed its stability and susceptibility to various interferences, and conducted real-sample tests using glove extraction to evaluate its capability in real-world settings. Spike recovery analysis revealed an extraction efficiency of 82.5% to 87.5% for leather gloves and 68.9% to 71.9% for nitrile gloves. This platform demonstrates strong selectivity against interferences, with the enzyme retaining 90% activity even after a week under the established storage protocols with room for further investigation. While primarily a proof of concept, this device shows promise as an additional tool for pesticide detection, with potential future integration into multiplexed devices. Assessment of pesticide exposure using a fast-flow capillary device (created with Bio.Render.com).
doi_str_mv 10.1039/d4an01203h
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1039_D4AN01203H</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3123808056</sourcerecordid><originalsourceid>FETCH-LOGICAL-c262t-91b3672b989aea5275f7d76326ed902fc389a8d0a93105267fb3dbe5fd415cad3</originalsourceid><addsrcrecordid>eNpdkc1v1DAQxS0Earell95BlnpBSAF_xE58rLaUIlX0Us6RE49VV4kdPEnp_ve4bCkSp9HM_DSa9x4hp5x94kyaz662kXHB5N0rsuFS15VSon1NNowxWQmt6kNyhHhfWs4UOyCH0tRGMV1vyMPWzmEcbd5Vfky_qMvhASKdwpCTH9fgwkARIqZMe4vgaIp02eWEIZaW-jL3Fhe6IuTK5wDRjTtqEQFxgrjQ5OkMuIQhOKDwOCdcM-Bb8sbbEeHkuR6TH5dfbrdX1fXN12_b8-tqEFosleG91I3oTWssWCUa5RvXaCk0OMOEH2RZtI5ZI4syoRvfS9eD8q7marBOHpMP-7tzTj_X8kc3BRygCI6QVuwkF7JlLVO6oGf_ofdpzbF890QZVctGm0J93FPFH8QMvptzmIp9HWfdUxrdRX3-_U8aVwV-_3xy7SdwL-hf-wvwbg9kHF62_-KUvwEGepCI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3129543769</pqid></control><display><type>article</type><title>Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Hefner, Claire E ; Aryal, Prakash ; Brack, Eric ; Alexander, Todd ; Henry, Charles S</creator><creatorcontrib>Hefner, Claire E ; Aryal, Prakash ; Brack, Eric ; Alexander, Todd ; Henry, Charles S</creatorcontrib><description>Pesticides are primarily used in agriculture to protect crops and extend their longevity. However, pesticide exposure has been linked to various acute and chronic health effects, raising significant environmental concerns. Current detection methods are often expensive and time-consuming, relying on complex instruments. Although enzyme-inhibition-based microfluidic paper-based analytical device (mPAD) platforms offer an easier alternative, they suffer from slow analyte transport and analyte adsorption issues in microchannels. Consequently, there is a need for a fast, simple, and cost-effective point-of-need platform for pesticide sensing. In this study, we present a rapid microfluidic platform for on-site pesticide residue detection. Unlike traditional mPAD platforms, our system transports pesticide samples through hollow capillary channels within seconds without adsorption of pesticides in the microchannels. While much research has focused on acetylcholinesterase inhibition on paper, this study is the first to introduce a tyrosinase inhibition-based assay on a paper platform for pesticide detection. Ziram, a representative dithiocarbamate pesticide, was detected using a colorimetric enzymatic inhibition assay. A limit of detection (LoD) of 1.5 ppm was obtained. In this study, we optimized the fast-flow device, assessed its stability and susceptibility to various interferences, and conducted real-sample tests using glove extraction to evaluate its capability in real-world settings. Spike recovery analysis revealed an extraction efficiency of 82.5% to 87.5% for leather gloves and 68.9% to 71.9% for nitrile gloves. This platform demonstrates strong selectivity against interferences, with the enzyme retaining 90% activity even after a week under the established storage protocols with room for further investigation. While primarily a proof of concept, this device shows promise as an additional tool for pesticide detection, with potential future integration into multiplexed devices. Assessment of pesticide exposure using a fast-flow capillary device (created with Bio.Render.com).</description><identifier>ISSN: 0003-2654</identifier><identifier>ISSN: 1364-5528</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/d4an01203h</identifier><identifier>PMID: 39495064</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Adsorption ; Capillary flow ; Enzymes ; Gloves ; Leather ; Microchannels ; Microfluidics ; Pesticides ; Platforms ; Tyrosinase</subject><ispartof>Analyst (London), 2024-11, Vol.149 (23), p.5684-5692</ispartof><rights>Copyright Royal Society of Chemistry 2024</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c262t-91b3672b989aea5275f7d76326ed902fc389a8d0a93105267fb3dbe5fd415cad3</cites><orcidid>0000-0002-2739-8974 ; 0009-0006-8309-3901 ; 0000-0002-8671-7728</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,2818,2819,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/39495064$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Hefner, Claire E</creatorcontrib><creatorcontrib>Aryal, Prakash</creatorcontrib><creatorcontrib>Brack, Eric</creatorcontrib><creatorcontrib>Alexander, Todd</creatorcontrib><creatorcontrib>Henry, Charles S</creatorcontrib><title>Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>Pesticides are primarily used in agriculture to protect crops and extend their longevity. However, pesticide exposure has been linked to various acute and chronic health effects, raising significant environmental concerns. Current detection methods are often expensive and time-consuming, relying on complex instruments. Although enzyme-inhibition-based microfluidic paper-based analytical device (mPAD) platforms offer an easier alternative, they suffer from slow analyte transport and analyte adsorption issues in microchannels. Consequently, there is a need for a fast, simple, and cost-effective point-of-need platform for pesticide sensing. In this study, we present a rapid microfluidic platform for on-site pesticide residue detection. Unlike traditional mPAD platforms, our system transports pesticide samples through hollow capillary channels within seconds without adsorption of pesticides in the microchannels. While much research has focused on acetylcholinesterase inhibition on paper, this study is the first to introduce a tyrosinase inhibition-based assay on a paper platform for pesticide detection. Ziram, a representative dithiocarbamate pesticide, was detected using a colorimetric enzymatic inhibition assay. A limit of detection (LoD) of 1.5 ppm was obtained. In this study, we optimized the fast-flow device, assessed its stability and susceptibility to various interferences, and conducted real-sample tests using glove extraction to evaluate its capability in real-world settings. Spike recovery analysis revealed an extraction efficiency of 82.5% to 87.5% for leather gloves and 68.9% to 71.9% for nitrile gloves. This platform demonstrates strong selectivity against interferences, with the enzyme retaining 90% activity even after a week under the established storage protocols with room for further investigation. While primarily a proof of concept, this device shows promise as an additional tool for pesticide detection, with potential future integration into multiplexed devices. Assessment of pesticide exposure using a fast-flow capillary device (created with Bio.Render.com).</description><subject>Adsorption</subject><subject>Capillary flow</subject><subject>Enzymes</subject><subject>Gloves</subject><subject>Leather</subject><subject>Microchannels</subject><subject>Microfluidics</subject><subject>Pesticides</subject><subject>Platforms</subject><subject>Tyrosinase</subject><issn>0003-2654</issn><issn>1364-5528</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNpdkc1v1DAQxS0Earell95BlnpBSAF_xE58rLaUIlX0Us6RE49VV4kdPEnp_ve4bCkSp9HM_DSa9x4hp5x94kyaz662kXHB5N0rsuFS15VSon1NNowxWQmt6kNyhHhfWs4UOyCH0tRGMV1vyMPWzmEcbd5Vfky_qMvhASKdwpCTH9fgwkARIqZMe4vgaIp02eWEIZaW-jL3Fhe6IuTK5wDRjTtqEQFxgrjQ5OkMuIQhOKDwOCdcM-Bb8sbbEeHkuR6TH5dfbrdX1fXN12_b8-tqEFosleG91I3oTWssWCUa5RvXaCk0OMOEH2RZtI5ZI4syoRvfS9eD8q7marBOHpMP-7tzTj_X8kc3BRygCI6QVuwkF7JlLVO6oGf_ofdpzbF890QZVctGm0J93FPFH8QMvptzmIp9HWfdUxrdRX3-_U8aVwV-_3xy7SdwL-hf-wvwbg9kHF62_-KUvwEGepCI</recordid><startdate>20241118</startdate><enddate>20241118</enddate><creator>Hefner, Claire E</creator><creator>Aryal, Prakash</creator><creator>Brack, Eric</creator><creator>Alexander, Todd</creator><creator>Henry, Charles S</creator><general>Royal Society of Chemistry</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0002-2739-8974</orcidid><orcidid>https://orcid.org/0009-0006-8309-3901</orcidid><orcidid>https://orcid.org/0000-0002-8671-7728</orcidid></search><sort><creationdate>20241118</creationdate><title>Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures</title><author>Hefner, Claire E ; Aryal, Prakash ; Brack, Eric ; Alexander, Todd ; Henry, Charles S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c262t-91b3672b989aea5275f7d76326ed902fc389a8d0a93105267fb3dbe5fd415cad3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Adsorption</topic><topic>Capillary flow</topic><topic>Enzymes</topic><topic>Gloves</topic><topic>Leather</topic><topic>Microchannels</topic><topic>Microfluidics</topic><topic>Pesticides</topic><topic>Platforms</topic><topic>Tyrosinase</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hefner, Claire E</creatorcontrib><creatorcontrib>Aryal, Prakash</creatorcontrib><creatorcontrib>Brack, Eric</creatorcontrib><creatorcontrib>Alexander, Todd</creatorcontrib><creatorcontrib>Henry, Charles S</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hefner, Claire E</au><au>Aryal, Prakash</au><au>Brack, Eric</au><au>Alexander, Todd</au><au>Henry, Charles S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2024-11-18</date><risdate>2024</risdate><volume>149</volume><issue>23</issue><spage>5684</spage><epage>5692</epage><pages>5684-5692</pages><issn>0003-2654</issn><issn>1364-5528</issn><eissn>1364-5528</eissn><abstract>Pesticides are primarily used in agriculture to protect crops and extend their longevity. However, pesticide exposure has been linked to various acute and chronic health effects, raising significant environmental concerns. Current detection methods are often expensive and time-consuming, relying on complex instruments. Although enzyme-inhibition-based microfluidic paper-based analytical device (mPAD) platforms offer an easier alternative, they suffer from slow analyte transport and analyte adsorption issues in microchannels. Consequently, there is a need for a fast, simple, and cost-effective point-of-need platform for pesticide sensing. In this study, we present a rapid microfluidic platform for on-site pesticide residue detection. Unlike traditional mPAD platforms, our system transports pesticide samples through hollow capillary channels within seconds without adsorption of pesticides in the microchannels. While much research has focused on acetylcholinesterase inhibition on paper, this study is the first to introduce a tyrosinase inhibition-based assay on a paper platform for pesticide detection. Ziram, a representative dithiocarbamate pesticide, was detected using a colorimetric enzymatic inhibition assay. A limit of detection (LoD) of 1.5 ppm was obtained. In this study, we optimized the fast-flow device, assessed its stability and susceptibility to various interferences, and conducted real-sample tests using glove extraction to evaluate its capability in real-world settings. Spike recovery analysis revealed an extraction efficiency of 82.5% to 87.5% for leather gloves and 68.9% to 71.9% for nitrile gloves. This platform demonstrates strong selectivity against interferences, with the enzyme retaining 90% activity even after a week under the established storage protocols with room for further investigation. While primarily a proof of concept, this device shows promise as an additional tool for pesticide detection, with potential future integration into multiplexed devices. Assessment of pesticide exposure using a fast-flow capillary device (created with Bio.Render.com).</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>39495064</pmid><doi>10.1039/d4an01203h</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-2739-8974</orcidid><orcidid>https://orcid.org/0009-0006-8309-3901</orcidid><orcidid>https://orcid.org/0000-0002-8671-7728</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof Analyst (London), 2024-11, Vol.149 (23), p.5684-5692
issn 0003-2654
1364-5528
1364-5528
language eng
recordid cdi_crossref_primary_10_1039_D4AN01203H
source Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Adsorption
Capillary flow
Enzymes
Gloves
Leather
Microchannels
Microfluidics
Pesticides
Platforms
Tyrosinase
title Capillary-flow driven microfluidic sensor based on tyrosinase for fast user-friendly assessment of pesticide exposures
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T20%3A29%3A50IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Capillary-flow%20driven%20microfluidic%20sensor%20based%20on%20tyrosinase%20for%20fast%20user-friendly%20assessment%20of%20pesticide%20exposures&rft.jtitle=Analyst%20(London)&rft.au=Hefner,%20Claire%20E&rft.date=2024-11-18&rft.volume=149&rft.issue=23&rft.spage=5684&rft.epage=5692&rft.pages=5684-5692&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/d4an01203h&rft_dat=%3Cproquest_cross%3E3123808056%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3129543769&rft_id=info:pmid/39495064&rfr_iscdi=true