A study on a natural pyrite sample as a potential reference material for simultaneous measurement of sulfur and iron isotopes using fs-LA-MC-ICP-MSs
Pyrite has been extensively utilized for tracing geological processes through its iron and sulfur isotope micro-analysis. However, the lack of matrix-matched reference materials with characterized Fe and S isotopic compositions poses a challenge. In this study, we examined a natural pyrite sample (I...
Gespeichert in:
Veröffentlicht in: | Journal of analytical atomic spectrometry 2024-03, Vol.39 (3), p.723-734 |
---|---|
Hauptverfasser: | , , , , , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Pyrite has been extensively utilized for tracing geological processes through its iron and sulfur isotope micro-analysis. However, the lack of matrix-matched reference materials with characterized Fe and S isotopic compositions poses a challenge. In this study, we examined a natural pyrite sample (IGGPy-1) to evaluate its potential as a matrix-matched reference material for
in situ
micro-analysis of iron and sulfur isotopes. Electron probe microanalysis (EPMA) confirmed the homogeneity of major elements without any growth zoning in pyrite grains. Random spot isotopic analyses conducted using laser ablation multi-collector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS) yielded variances in
δ
56
Fe and
δ
34
S of 0.07‰ (2S,
N
= 105) and 0.13‰ (2S,
N
= 105), respectively. Based on the results and statistical analysis, it was determined that the IGGPy-1 sample was isotopically homogeneous and had the potential to be used as a reference material. The
δ
34
S
VCDT
value, measured using elemental analyzer-isotope ratio mass spectrometry (EA-IRMS), was 17.09 ± 0.30‰ (2S,
N
= 6). Additionally,
δ
56
Fe
IRMM-014
and
δ
57
Fe
IRMM-014
values, measured using solution-nebulizing multi-collector inductively coupled plasma mass spectrometry (SN-MC-ICP-MS), were −1.31 ± 0.06‰ (2S,
N
= 21) and −1.94 ± 0.12‰ (2S,
N
= 21), respectively. These values are recommended as the isotopic reference values for IGGPy-1. Since the samples with complex core-rim textures resulting from multiple stages in the formation of many sulfide deposits face a significant risk of mismatch in the Fe and S isotopic data obtained from different analytical domains, we presented the technique of simultaneous
in situ
measurements of Fe-S isotopes in pyrite using a single laser spot by coupling a femtosecond laser ablation system with two sets of MC-ICP-MS. Furthermore, our results clearly demonstrated the significant impact of position effects on the accuracy of Fe and S isotopic data. Therefore, it is crucial to identify appropriate domains within the ablation chamber for placing the "standard" and samples for mitigating these effects.
A natural pyrite sample has been meticulously examined and identified as a promising reference material. It is ideally suitable for the simultaneous measurement of S and Fe isotopic compositions in pyrite samples using LA-MC-ICP-MS. |
---|---|
ISSN: | 0267-9477 1364-5544 |
DOI: | 10.1039/d3ja00351e |