3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A

A novel platform of microfluidic paper-based analytical devices (μPADs) for dual detection of bisphenol A (BPA), a model analyte, was fabricated using an electronic digital plotter to create the stacked layer of μPADs and generate the lateral-flow channel without using an external pump. Two detectio...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Analyst (London) 2020-02, Vol.145 (4), p.1491-1498
Hauptverfasser: Yukird, Jutiporn, Soum, Veasna, Kwon, Oh-Sun, Shin, Kwanwoo, Chailapakul, Orawon, Rodthongkum, Nadnudda
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1498
container_issue 4
container_start_page 1491
container_title Analyst (London)
container_volume 145
creator Yukird, Jutiporn
Soum, Veasna
Kwon, Oh-Sun
Shin, Kwanwoo
Chailapakul, Orawon
Rodthongkum, Nadnudda
description A novel platform of microfluidic paper-based analytical devices (μPADs) for dual detection of bisphenol A (BPA), a model analyte, was fabricated using an electronic digital plotter to create the stacked layer of μPADs and generate the lateral-flow channel without using an external pump. Two detection techniques, including electrochemical detection and laser desorption ionization mass spectrometric detection (LDI-MS), were used complementarily to improve the precision in the detection of BPA. The fluid sample was delivered to both detection zones by the capillary action, automatically generated from the fabricated microfluidic device. For an electrochemical sensor, two ballpoint pens filled with silver nanoparticles (AgNPs) and multiwall carbon nanotube (MWCNT) ink were used to print onto the paper with a contact printing method using a digital plotter. To further improve the sensitivity, zinc oxide (ZnO) was used to modify both electrochemical and LDI-MS detection zones. For BPA detection, high electrocatalytic properties and strong UV absorption of ZnO promote the electron transfer in the electrochemical sensor and ionization efficiency in LDI-MS with low interferences compared with a conventional organic matrix. Under optimal conditions, this platform showed a dual detection capability for BPA with a detection limit of 0.35 μM for electrochemical detection and with an ultralow detection limit of 0.01 pM for LDI-MS. This novel platform might be very useful for trace analyses requiring high precision detection of various analytes. A novel platform of 3D paper-based microfluidic device (μPADs) was fabricated by a digital plotter for high precision analysis of bisphenol A using electrochemistry along with LDI-MS detection.
doi_str_mv 10.1039/c9an01738k
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1039_C9AN01738K</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2355816432</sourcerecordid><originalsourceid>FETCH-LOGICAL-c337t-706d521e3886db1955287270f42b401dd1ad7d66190c1289931449182de137973</originalsourceid><addsrcrecordid>eNpdkdFL3EAQhxepeOfVF99bFnwRIXZnJ8nu-nacWsXDQqnPYbO7obFJNu4mgv-9ud55hb7MMMzHj-EbQk6BXQJD9c0o3TEQKP8ckDlgniZZxuUnMmeMYcLzLJ2R4xifpxFYxo7IDEEKLnk2Jz_xmva6dyEpdXSWtrUJvmrG2taGWvdaG3dFNe38q2uoHXWTWDc4M9S-o32jh8qHlvqKlnXsf7vON3T5mRxWuonuZNcX5On25tfqLln_-H6_Wq4TgyiGRLDcZhwcSpnbEtTmZsEFq1JepgysBW2FzXNQzACXSiGkqQLJrQMUSuCCnG9z--BfRheHoq2jcU2jO-fHWHBEhlxt6oKc_Yc--zF003UTlWUS8hT5RF1sqUlBjMFVRR_qVoe3AlixMV2s1PLxr-mHCf66ixzL1tk9-qF2Ar5sgRDNfvvvVfgOAFh_Kw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2355816432</pqid></control><display><type>article</type><title>3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A</title><source>Royal Society of Chemistry Journals Archive (1841-2007)</source><source>Royal Society Of Chemistry Journals 2008-</source><source>Alma/SFX Local Collection</source><creator>Yukird, Jutiporn ; Soum, Veasna ; Kwon, Oh-Sun ; Shin, Kwanwoo ; Chailapakul, Orawon ; Rodthongkum, Nadnudda</creator><creatorcontrib>Yukird, Jutiporn ; Soum, Veasna ; Kwon, Oh-Sun ; Shin, Kwanwoo ; Chailapakul, Orawon ; Rodthongkum, Nadnudda</creatorcontrib><description>A novel platform of microfluidic paper-based analytical devices (μPADs) for dual detection of bisphenol A (BPA), a model analyte, was fabricated using an electronic digital plotter to create the stacked layer of μPADs and generate the lateral-flow channel without using an external pump. Two detection techniques, including electrochemical detection and laser desorption ionization mass spectrometric detection (LDI-MS), were used complementarily to improve the precision in the detection of BPA. The fluid sample was delivered to both detection zones by the capillary action, automatically generated from the fabricated microfluidic device. For an electrochemical sensor, two ballpoint pens filled with silver nanoparticles (AgNPs) and multiwall carbon nanotube (MWCNT) ink were used to print onto the paper with a contact printing method using a digital plotter. To further improve the sensitivity, zinc oxide (ZnO) was used to modify both electrochemical and LDI-MS detection zones. For BPA detection, high electrocatalytic properties and strong UV absorption of ZnO promote the electron transfer in the electrochemical sensor and ionization efficiency in LDI-MS with low interferences compared with a conventional organic matrix. Under optimal conditions, this platform showed a dual detection capability for BPA with a detection limit of 0.35 μM for electrochemical detection and with an ultralow detection limit of 0.01 pM for LDI-MS. This novel platform might be very useful for trace analyses requiring high precision detection of various analytes. A novel platform of 3D paper-based microfluidic device (μPADs) was fabricated by a digital plotter for high precision analysis of bisphenol A using electrochemistry along with LDI-MS detection.</description><identifier>ISSN: 0003-2654</identifier><identifier>EISSN: 1364-5528</identifier><identifier>DOI: 10.1039/c9an01738k</identifier><identifier>PMID: 31872825</identifier><language>eng</language><publisher>England: Royal Society of Chemistry</publisher><subject>Bisphenol A ; Capillarity ; Chemical sensors ; Electrochemical analysis ; Electron transfer ; Ionization ; Ions ; Microfluidic devices ; Multi wall carbon nanotubes ; Nanoparticles ; Plotters ; Silver ; Spectrometry ; Zinc oxide ; Zinc oxides</subject><ispartof>Analyst (London), 2020-02, Vol.145 (4), p.1491-1498</ispartof><rights>Copyright Royal Society of Chemistry 2020</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c337t-706d521e3886db1955287270f42b401dd1ad7d66190c1289931449182de137973</citedby><cites>FETCH-LOGICAL-c337t-706d521e3886db1955287270f42b401dd1ad7d66190c1289931449182de137973</cites><orcidid>0000-0003-4164-2379 ; 0000-0002-7563-8581 ; 0000-0002-0379-5166</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,2829,2830,27922,27923</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/31872825$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Yukird, Jutiporn</creatorcontrib><creatorcontrib>Soum, Veasna</creatorcontrib><creatorcontrib>Kwon, Oh-Sun</creatorcontrib><creatorcontrib>Shin, Kwanwoo</creatorcontrib><creatorcontrib>Chailapakul, Orawon</creatorcontrib><creatorcontrib>Rodthongkum, Nadnudda</creatorcontrib><title>3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A</title><title>Analyst (London)</title><addtitle>Analyst</addtitle><description>A novel platform of microfluidic paper-based analytical devices (μPADs) for dual detection of bisphenol A (BPA), a model analyte, was fabricated using an electronic digital plotter to create the stacked layer of μPADs and generate the lateral-flow channel without using an external pump. Two detection techniques, including electrochemical detection and laser desorption ionization mass spectrometric detection (LDI-MS), were used complementarily to improve the precision in the detection of BPA. The fluid sample was delivered to both detection zones by the capillary action, automatically generated from the fabricated microfluidic device. For an electrochemical sensor, two ballpoint pens filled with silver nanoparticles (AgNPs) and multiwall carbon nanotube (MWCNT) ink were used to print onto the paper with a contact printing method using a digital plotter. To further improve the sensitivity, zinc oxide (ZnO) was used to modify both electrochemical and LDI-MS detection zones. For BPA detection, high electrocatalytic properties and strong UV absorption of ZnO promote the electron transfer in the electrochemical sensor and ionization efficiency in LDI-MS with low interferences compared with a conventional organic matrix. Under optimal conditions, this platform showed a dual detection capability for BPA with a detection limit of 0.35 μM for electrochemical detection and with an ultralow detection limit of 0.01 pM for LDI-MS. This novel platform might be very useful for trace analyses requiring high precision detection of various analytes. A novel platform of 3D paper-based microfluidic device (μPADs) was fabricated by a digital plotter for high precision analysis of bisphenol A using electrochemistry along with LDI-MS detection.</description><subject>Bisphenol A</subject><subject>Capillarity</subject><subject>Chemical sensors</subject><subject>Electrochemical analysis</subject><subject>Electron transfer</subject><subject>Ionization</subject><subject>Ions</subject><subject>Microfluidic devices</subject><subject>Multi wall carbon nanotubes</subject><subject>Nanoparticles</subject><subject>Plotters</subject><subject>Silver</subject><subject>Spectrometry</subject><subject>Zinc oxide</subject><subject>Zinc oxides</subject><issn>0003-2654</issn><issn>1364-5528</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2020</creationdate><recordtype>article</recordtype><recordid>eNpdkdFL3EAQhxepeOfVF99bFnwRIXZnJ8nu-nacWsXDQqnPYbO7obFJNu4mgv-9ud55hb7MMMzHj-EbQk6BXQJD9c0o3TEQKP8ckDlgniZZxuUnMmeMYcLzLJ2R4xifpxFYxo7IDEEKLnk2Jz_xmva6dyEpdXSWtrUJvmrG2taGWvdaG3dFNe38q2uoHXWTWDc4M9S-o32jh8qHlvqKlnXsf7vON3T5mRxWuonuZNcX5On25tfqLln_-H6_Wq4TgyiGRLDcZhwcSpnbEtTmZsEFq1JepgysBW2FzXNQzACXSiGkqQLJrQMUSuCCnG9z--BfRheHoq2jcU2jO-fHWHBEhlxt6oKc_Yc--zF003UTlWUS8hT5RF1sqUlBjMFVRR_qVoe3AlixMV2s1PLxr-mHCf66ixzL1tk9-qF2Ar5sgRDNfvvvVfgOAFh_Kw</recordid><startdate>20200217</startdate><enddate>20200217</enddate><creator>Yukird, Jutiporn</creator><creator>Soum, Veasna</creator><creator>Kwon, Oh-Sun</creator><creator>Shin, Kwanwoo</creator><creator>Chailapakul, Orawon</creator><creator>Rodthongkum, Nadnudda</creator><general>Royal Society of Chemistry</general><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7SR</scope><scope>7U5</scope><scope>8BQ</scope><scope>8FD</scope><scope>JG9</scope><scope>L7M</scope><scope>7X8</scope><orcidid>https://orcid.org/0000-0003-4164-2379</orcidid><orcidid>https://orcid.org/0000-0002-7563-8581</orcidid><orcidid>https://orcid.org/0000-0002-0379-5166</orcidid></search><sort><creationdate>20200217</creationdate><title>3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A</title><author>Yukird, Jutiporn ; Soum, Veasna ; Kwon, Oh-Sun ; Shin, Kwanwoo ; Chailapakul, Orawon ; Rodthongkum, Nadnudda</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c337t-706d521e3886db1955287270f42b401dd1ad7d66190c1289931449182de137973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2020</creationdate><topic>Bisphenol A</topic><topic>Capillarity</topic><topic>Chemical sensors</topic><topic>Electrochemical analysis</topic><topic>Electron transfer</topic><topic>Ionization</topic><topic>Ions</topic><topic>Microfluidic devices</topic><topic>Multi wall carbon nanotubes</topic><topic>Nanoparticles</topic><topic>Plotters</topic><topic>Silver</topic><topic>Spectrometry</topic><topic>Zinc oxide</topic><topic>Zinc oxides</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Yukird, Jutiporn</creatorcontrib><creatorcontrib>Soum, Veasna</creatorcontrib><creatorcontrib>Kwon, Oh-Sun</creatorcontrib><creatorcontrib>Shin, Kwanwoo</creatorcontrib><creatorcontrib>Chailapakul, Orawon</creatorcontrib><creatorcontrib>Rodthongkum, Nadnudda</creatorcontrib><collection>PubMed</collection><collection>CrossRef</collection><collection>Engineered Materials Abstracts</collection><collection>Solid State and Superconductivity Abstracts</collection><collection>METADEX</collection><collection>Technology Research Database</collection><collection>Materials Research Database</collection><collection>Advanced Technologies Database with Aerospace</collection><collection>MEDLINE - Academic</collection><jtitle>Analyst (London)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Yukird, Jutiporn</au><au>Soum, Veasna</au><au>Kwon, Oh-Sun</au><au>Shin, Kwanwoo</au><au>Chailapakul, Orawon</au><au>Rodthongkum, Nadnudda</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A</atitle><jtitle>Analyst (London)</jtitle><addtitle>Analyst</addtitle><date>2020-02-17</date><risdate>2020</risdate><volume>145</volume><issue>4</issue><spage>1491</spage><epage>1498</epage><pages>1491-1498</pages><issn>0003-2654</issn><eissn>1364-5528</eissn><abstract>A novel platform of microfluidic paper-based analytical devices (μPADs) for dual detection of bisphenol A (BPA), a model analyte, was fabricated using an electronic digital plotter to create the stacked layer of μPADs and generate the lateral-flow channel without using an external pump. Two detection techniques, including electrochemical detection and laser desorption ionization mass spectrometric detection (LDI-MS), were used complementarily to improve the precision in the detection of BPA. The fluid sample was delivered to both detection zones by the capillary action, automatically generated from the fabricated microfluidic device. For an electrochemical sensor, two ballpoint pens filled with silver nanoparticles (AgNPs) and multiwall carbon nanotube (MWCNT) ink were used to print onto the paper with a contact printing method using a digital plotter. To further improve the sensitivity, zinc oxide (ZnO) was used to modify both electrochemical and LDI-MS detection zones. For BPA detection, high electrocatalytic properties and strong UV absorption of ZnO promote the electron transfer in the electrochemical sensor and ionization efficiency in LDI-MS with low interferences compared with a conventional organic matrix. Under optimal conditions, this platform showed a dual detection capability for BPA with a detection limit of 0.35 μM for electrochemical detection and with an ultralow detection limit of 0.01 pM for LDI-MS. This novel platform might be very useful for trace analyses requiring high precision detection of various analytes. A novel platform of 3D paper-based microfluidic device (μPADs) was fabricated by a digital plotter for high precision analysis of bisphenol A using electrochemistry along with LDI-MS detection.</abstract><cop>England</cop><pub>Royal Society of Chemistry</pub><pmid>31872825</pmid><doi>10.1039/c9an01738k</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0003-4164-2379</orcidid><orcidid>https://orcid.org/0000-0002-7563-8581</orcidid><orcidid>https://orcid.org/0000-0002-0379-5166</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0003-2654
ispartof Analyst (London), 2020-02, Vol.145 (4), p.1491-1498
issn 0003-2654
1364-5528
language eng
recordid cdi_crossref_primary_10_1039_C9AN01738K
source Royal Society of Chemistry Journals Archive (1841-2007); Royal Society Of Chemistry Journals 2008-; Alma/SFX Local Collection
subjects Bisphenol A
Capillarity
Chemical sensors
Electrochemical analysis
Electron transfer
Ionization
Ions
Microfluidic devices
Multi wall carbon nanotubes
Nanoparticles
Plotters
Silver
Spectrometry
Zinc oxide
Zinc oxides
title 3D paper-based microfluidic device: a novel dual-detection platform of bisphenol A
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T02%3A55%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=3D%20paper-based%20microfluidic%20device:%20a%20novel%20dual-detection%20platform%20of%20bisphenol%20A&rft.jtitle=Analyst%20(London)&rft.au=Yukird,%20Jutiporn&rft.date=2020-02-17&rft.volume=145&rft.issue=4&rft.spage=1491&rft.epage=1498&rft.pages=1491-1498&rft.issn=0003-2654&rft.eissn=1364-5528&rft_id=info:doi/10.1039/c9an01738k&rft_dat=%3Cproquest_cross%3E2355816432%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2355816432&rft_id=info:pmid/31872825&rfr_iscdi=true