Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples
Ag–TiO 2 –graphene pastes modified with inulin, and l -alanine tert -butyl ester nitrate ( l -Ala-C 4 - l -Lac), respectively, were proposed for the molecular recognition of carcinoembryonic antigen (CEA) from whole blood samples. High levels of CEA are associated with different types of cancer, one...
Gespeichert in:
Veröffentlicht in: | RSC advances 2017, Vol.7 (45), p.28419-28426 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 28426 |
---|---|
container_issue | 45 |
container_start_page | 28419 |
container_title | RSC advances |
container_volume | 7 |
creator | Gugoasa, Livia Alexandra Muklive AĺOgaidi, Ahmed Jassim Stefan-van Staden, Raluca-Ioana El-Khatib, Ahed Rosu, Marcela-Corina Pruneanu, Stela |
description | Ag–TiO
2
–graphene pastes modified with inulin, and
l
-alanine
tert
-butyl ester nitrate (
l
-Ala-C
4
-
l
-Lac), respectively, were proposed for the molecular recognition of carcinoembryonic antigen (CEA) from whole blood samples. High levels of CEA are associated with different types of cancer, one of them being colorectal cancer. Both sensors gave high reliability for the measurements, and also high sensitivity and selectivity were recorded. The modes used were stochastic mode for qualitative and quantitative analysis of CEA, and differential pulse voltammetry for the quantitative measurement of CEA. The lowest limit of determination (20.5 fg mL
−1
) was recorded when the multimode sensor based on Ag–TiO
2
–graphene paste was modified with the inulin IQ. |
doi_str_mv | 10.1039/C7RA03842A |
format | Article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1039_C7RA03842A</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1039_C7RA03842A</sourcerecordid><originalsourceid>FETCH-LOGICAL-c76A-6971a76ab4ea5f8be161fdf92d1e9914fc7e4fa2f867c4acd7dbfd20aa51d1973</originalsourceid><addsrcrecordid>eNpNkN1KAzEQhYMoWGpvfIJcC6tJdpt0L5fiT6FSkN4vs8lkG9lNSrJFeuc7CD6gT-IWBZ2bOQxnPjiHkGvObjnLy7uleqlYvihEdUYmghUyE0yW5__0JZml9MrGkXMuJJ-Qz-dDN7g-GKS90zEk9CnERBtIaGjwtGq_3j-2bkMFHUUbYb9DP5phwOigS_RwMtoQ6bAbz6FDfegg0og6tN4NbmQESzVE7XzAvonH4J2m4AfXoqfO07fd-EWbLgRDE_T7DtMVubAjHGe_e0q2D_fb5VO23jyultU600pWmSwVByWhKRDmdtEgl9waWwrDsSx5YbXCwoKwC6l0Adoo01gjGMCcG16qfEpufrCn5CmirffR9RCPNWf1qdP6r9P8G2Kpb1k</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples</title><source>Directory of Open Access Journals</source><source>EZB Electronic Journals Library</source><creator>Gugoasa, Livia Alexandra ; Muklive AĺOgaidi, Ahmed Jassim ; Stefan-van Staden, Raluca-Ioana ; El-Khatib, Ahed ; Rosu, Marcela-Corina ; Pruneanu, Stela</creator><creatorcontrib>Gugoasa, Livia Alexandra ; Muklive AĺOgaidi, Ahmed Jassim ; Stefan-van Staden, Raluca-Ioana ; El-Khatib, Ahed ; Rosu, Marcela-Corina ; Pruneanu, Stela</creatorcontrib><description>Ag–TiO
2
–graphene pastes modified with inulin, and
l
-alanine
tert
-butyl ester nitrate (
l
-Ala-C
4
-
l
-Lac), respectively, were proposed for the molecular recognition of carcinoembryonic antigen (CEA) from whole blood samples. High levels of CEA are associated with different types of cancer, one of them being colorectal cancer. Both sensors gave high reliability for the measurements, and also high sensitivity and selectivity were recorded. The modes used were stochastic mode for qualitative and quantitative analysis of CEA, and differential pulse voltammetry for the quantitative measurement of CEA. The lowest limit of determination (20.5 fg mL
−1
) was recorded when the multimode sensor based on Ag–TiO
2
–graphene paste was modified with the inulin IQ.</description><identifier>ISSN: 2046-2069</identifier><identifier>EISSN: 2046-2069</identifier><identifier>DOI: 10.1039/C7RA03842A</identifier><language>eng</language><ispartof>RSC advances, 2017, Vol.7 (45), p.28419-28426</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c76A-6971a76ab4ea5f8be161fdf92d1e9914fc7e4fa2f867c4acd7dbfd20aa51d1973</citedby><cites>FETCH-LOGICAL-c76A-6971a76ab4ea5f8be161fdf92d1e9914fc7e4fa2f867c4acd7dbfd20aa51d1973</cites><orcidid>0000-0001-8244-2483</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,864,4014,27914,27915,27916</link.rule.ids></links><search><creatorcontrib>Gugoasa, Livia Alexandra</creatorcontrib><creatorcontrib>Muklive AĺOgaidi, Ahmed Jassim</creatorcontrib><creatorcontrib>Stefan-van Staden, Raluca-Ioana</creatorcontrib><creatorcontrib>El-Khatib, Ahed</creatorcontrib><creatorcontrib>Rosu, Marcela-Corina</creatorcontrib><creatorcontrib>Pruneanu, Stela</creatorcontrib><title>Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples</title><title>RSC advances</title><description>Ag–TiO
2
–graphene pastes modified with inulin, and
l
-alanine
tert
-butyl ester nitrate (
l
-Ala-C
4
-
l
-Lac), respectively, were proposed for the molecular recognition of carcinoembryonic antigen (CEA) from whole blood samples. High levels of CEA are associated with different types of cancer, one of them being colorectal cancer. Both sensors gave high reliability for the measurements, and also high sensitivity and selectivity were recorded. The modes used were stochastic mode for qualitative and quantitative analysis of CEA, and differential pulse voltammetry for the quantitative measurement of CEA. The lowest limit of determination (20.5 fg mL
−1
) was recorded when the multimode sensor based on Ag–TiO
2
–graphene paste was modified with the inulin IQ.</description><issn>2046-2069</issn><issn>2046-2069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNpNkN1KAzEQhYMoWGpvfIJcC6tJdpt0L5fiT6FSkN4vs8lkG9lNSrJFeuc7CD6gT-IWBZ2bOQxnPjiHkGvObjnLy7uleqlYvihEdUYmghUyE0yW5__0JZml9MrGkXMuJJ-Qz-dDN7g-GKS90zEk9CnERBtIaGjwtGq_3j-2bkMFHUUbYb9DP5phwOigS_RwMtoQ6bAbz6FDfegg0og6tN4NbmQESzVE7XzAvonH4J2m4AfXoqfO07fd-EWbLgRDE_T7DtMVubAjHGe_e0q2D_fb5VO23jyultU600pWmSwVByWhKRDmdtEgl9waWwrDsSx5YbXCwoKwC6l0Adoo01gjGMCcG16qfEpufrCn5CmirffR9RCPNWf1qdP6r9P8G2Kpb1k</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Gugoasa, Livia Alexandra</creator><creator>Muklive AĺOgaidi, Ahmed Jassim</creator><creator>Stefan-van Staden, Raluca-Ioana</creator><creator>El-Khatib, Ahed</creator><creator>Rosu, Marcela-Corina</creator><creator>Pruneanu, Stela</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8244-2483</orcidid></search><sort><creationdate>2017</creationdate><title>Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples</title><author>Gugoasa, Livia Alexandra ; Muklive AĺOgaidi, Ahmed Jassim ; Stefan-van Staden, Raluca-Ioana ; El-Khatib, Ahed ; Rosu, Marcela-Corina ; Pruneanu, Stela</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c76A-6971a76ab4ea5f8be161fdf92d1e9914fc7e4fa2f867c4acd7dbfd20aa51d1973</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gugoasa, Livia Alexandra</creatorcontrib><creatorcontrib>Muklive AĺOgaidi, Ahmed Jassim</creatorcontrib><creatorcontrib>Stefan-van Staden, Raluca-Ioana</creatorcontrib><creatorcontrib>El-Khatib, Ahed</creatorcontrib><creatorcontrib>Rosu, Marcela-Corina</creatorcontrib><creatorcontrib>Pruneanu, Stela</creatorcontrib><collection>CrossRef</collection><jtitle>RSC advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gugoasa, Livia Alexandra</au><au>Muklive AĺOgaidi, Ahmed Jassim</au><au>Stefan-van Staden, Raluca-Ioana</au><au>El-Khatib, Ahed</au><au>Rosu, Marcela-Corina</au><au>Pruneanu, Stela</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples</atitle><jtitle>RSC advances</jtitle><date>2017</date><risdate>2017</risdate><volume>7</volume><issue>45</issue><spage>28419</spage><epage>28426</epage><pages>28419-28426</pages><issn>2046-2069</issn><eissn>2046-2069</eissn><abstract>Ag–TiO
2
–graphene pastes modified with inulin, and
l
-alanine
tert
-butyl ester nitrate (
l
-Ala-C
4
-
l
-Lac), respectively, were proposed for the molecular recognition of carcinoembryonic antigen (CEA) from whole blood samples. High levels of CEA are associated with different types of cancer, one of them being colorectal cancer. Both sensors gave high reliability for the measurements, and also high sensitivity and selectivity were recorded. The modes used were stochastic mode for qualitative and quantitative analysis of CEA, and differential pulse voltammetry for the quantitative measurement of CEA. The lowest limit of determination (20.5 fg mL
−1
) was recorded when the multimode sensor based on Ag–TiO
2
–graphene paste was modified with the inulin IQ.</abstract><doi>10.1039/C7RA03842A</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-8244-2483</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2046-2069 |
ispartof | RSC advances, 2017, Vol.7 (45), p.28419-28426 |
issn | 2046-2069 2046-2069 |
language | eng |
recordid | cdi_crossref_primary_10_1039_C7RA03842A |
source | Directory of Open Access Journals; EZB Electronic Journals Library |
title | Multimode microsensors based on Ag–TiO 2 –graphene materials used for the molecular recognition of carcinoembryonic antigen in whole blood samples |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T19%3A53%3A59IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Multimode%20microsensors%20based%20on%20Ag%E2%80%93TiO%202%20%E2%80%93graphene%20materials%20used%20for%20the%20molecular%20recognition%20of%20carcinoembryonic%20antigen%20in%20whole%20blood%20samples&rft.jtitle=RSC%20advances&rft.au=Gugoasa,%20Livia%20Alexandra&rft.date=2017&rft.volume=7&rft.issue=45&rft.spage=28419&rft.epage=28426&rft.pages=28419-28426&rft.issn=2046-2069&rft.eissn=2046-2069&rft_id=info:doi/10.1039/C7RA03842A&rft_dat=%3Ccrossref%3E10_1039_C7RA03842A%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |