Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples

A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) on to a glassy carbon electrode (GCE) and subsequent casting of silica sol-gel (SiSG) entrapped laccase (Lac) enzyme on to the MWCNT/GCE. The catalytic activity of laccase biosens...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RSC advances 2014-01, Vol.4 (11), p.57591-57599
Hauptverfasser: Gopal, P, Reddy, T. Madhusudana, Nagaraju, C, Narasimha, G
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 57599
container_issue 11
container_start_page 57591
container_title RSC advances
container_volume 4
creator Gopal, P
Reddy, T. Madhusudana
Nagaraju, C
Narasimha, G
description A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) on to a glassy carbon electrode (GCE) and subsequent casting of silica sol-gel (SiSG) entrapped laccase (Lac) enzyme on to the MWCNT/GCE. The catalytic activity of laccase biosensor was found to be good enough for sensitive determination of isoprenaline (ISP) with the aid of voltammetric techniques and we have also demonstrated the detailed electrochemical redox mechanism of ISP. From the effect of the pH, we have optimized the optimum pH as 6.5, and from effect of scan rate we have evaluated the kinetic parameters, heterogeneous rate constant, charge transfer coefficient and diffusion coefficient values. Furthermore the limit of detection (LOD) and limit of quantification (LOQ) values were found to be 1.8 × 10 −7 M and 6.0 × 10 −7 M, respectively. The simultaneous determination of ISP in the presence of uric acid (UA) and ascorbic acid (AA) was successfully carried out. The surface nature of the biosensor was characterized by using electrochemical impedance spectroscopy. Finally the validation of the proposed method was verified by the recovery of injection (ISP) in serum samples and their recoveries were found to be in a satisfactory range. The proposed method was found to have good repeatability, reproducibility and stability with low relative standard deviation (RSD) values. A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) followed by sol-gel entrapment of laccase (Lac) enzyme on to the GCE.
doi_str_mv 10.1039/c4ra09989c
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1039_C4RA09989C</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>1730085738</sourcerecordid><originalsourceid>FETCH-LOGICAL-c345t-2b61828ac8add9b13459229827717540f4601e7ea5c94ae26c9ad595cf25923b3</originalsourceid><addsrcrecordid>eNqFkU9r3DAQxU1JoCHNpfeCciuh20iyJVvHsKR_INAQkrOZHY9ZFdlyNN4s6Rfq14y6W9KeEgmhx7wfbw6vKN4r-VnJ0p1jlUA61zh8UxxpWdmFltYd_KffFifMP2U-1iht1VHx-zrRBAlmH8dPAtdZ4kzJ_9pNBIxdfhAeZ48QBExTyGJnxT47ggLhnCKuadgRARCBSax8ZBo5JjHHLaSORYhbEeiBgugobxj8-JzjOU6J8ho_kvCjWG-GHM2UNoNgGKZA_K447CEwnfz9j4u7L5e3y2-Lqx9fvy8vrhZYVmZe6JVVjW4AG-g6t1J56LR2ja5rVZtK9pWVimoCg64C0hYddMYZ7HUGy1V5XHzc504p3m-I53bwjBQCjBQ33Kq6lLIxddm8jlpT2SZfk9GzPYopMifq2yn5AdJjq2T7p7t2Wd1c7LpbZvjDHk6Mz9y_brN_-pLfTl1fPgFYKqVd</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>1654686865</pqid></control><display><type>article</type><title>Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples</title><source>Royal Society Of Chemistry Journals 2008-</source><creator>Gopal, P ; Reddy, T. Madhusudana ; Nagaraju, C ; Narasimha, G</creator><creatorcontrib>Gopal, P ; Reddy, T. Madhusudana ; Nagaraju, C ; Narasimha, G</creatorcontrib><description>A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) on to a glassy carbon electrode (GCE) and subsequent casting of silica sol-gel (SiSG) entrapped laccase (Lac) enzyme on to the MWCNT/GCE. The catalytic activity of laccase biosensor was found to be good enough for sensitive determination of isoprenaline (ISP) with the aid of voltammetric techniques and we have also demonstrated the detailed electrochemical redox mechanism of ISP. From the effect of the pH, we have optimized the optimum pH as 6.5, and from effect of scan rate we have evaluated the kinetic parameters, heterogeneous rate constant, charge transfer coefficient and diffusion coefficient values. Furthermore the limit of detection (LOD) and limit of quantification (LOQ) values were found to be 1.8 × 10 −7 M and 6.0 × 10 −7 M, respectively. The simultaneous determination of ISP in the presence of uric acid (UA) and ascorbic acid (AA) was successfully carried out. The surface nature of the biosensor was characterized by using electrochemical impedance spectroscopy. Finally the validation of the proposed method was verified by the recovery of injection (ISP) in serum samples and their recoveries were found to be in a satisfactory range. The proposed method was found to have good repeatability, reproducibility and stability with low relative standard deviation (RSD) values. A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) followed by sol-gel entrapment of laccase (Lac) enzyme on to the GCE.</description><identifier>ISSN: 2046-2069</identifier><identifier>EISSN: 2046-2069</identifier><identifier>DOI: 10.1039/c4ra09989c</identifier><language>eng</language><subject>Biosensors ; Electrochemical impedance spectroscopy ; Enzymes ; Laccase ; Recovery ; Reproducibility ; Serums</subject><ispartof>RSC advances, 2014-01, Vol.4 (11), p.57591-57599</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c345t-2b61828ac8add9b13459229827717540f4601e7ea5c94ae26c9ad595cf25923b3</citedby><cites>FETCH-LOGICAL-c345t-2b61828ac8add9b13459229827717540f4601e7ea5c94ae26c9ad595cf25923b3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Gopal, P</creatorcontrib><creatorcontrib>Reddy, T. Madhusudana</creatorcontrib><creatorcontrib>Nagaraju, C</creatorcontrib><creatorcontrib>Narasimha, G</creatorcontrib><title>Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples</title><title>RSC advances</title><description>A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) on to a glassy carbon electrode (GCE) and subsequent casting of silica sol-gel (SiSG) entrapped laccase (Lac) enzyme on to the MWCNT/GCE. The catalytic activity of laccase biosensor was found to be good enough for sensitive determination of isoprenaline (ISP) with the aid of voltammetric techniques and we have also demonstrated the detailed electrochemical redox mechanism of ISP. From the effect of the pH, we have optimized the optimum pH as 6.5, and from effect of scan rate we have evaluated the kinetic parameters, heterogeneous rate constant, charge transfer coefficient and diffusion coefficient values. Furthermore the limit of detection (LOD) and limit of quantification (LOQ) values were found to be 1.8 × 10 −7 M and 6.0 × 10 −7 M, respectively. The simultaneous determination of ISP in the presence of uric acid (UA) and ascorbic acid (AA) was successfully carried out. The surface nature of the biosensor was characterized by using electrochemical impedance spectroscopy. Finally the validation of the proposed method was verified by the recovery of injection (ISP) in serum samples and their recoveries were found to be in a satisfactory range. The proposed method was found to have good repeatability, reproducibility and stability with low relative standard deviation (RSD) values. A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) followed by sol-gel entrapment of laccase (Lac) enzyme on to the GCE.</description><subject>Biosensors</subject><subject>Electrochemical impedance spectroscopy</subject><subject>Enzymes</subject><subject>Laccase</subject><subject>Recovery</subject><subject>Reproducibility</subject><subject>Serums</subject><issn>2046-2069</issn><issn>2046-2069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqFkU9r3DAQxU1JoCHNpfeCciuh20iyJVvHsKR_INAQkrOZHY9ZFdlyNN4s6Rfq14y6W9KeEgmhx7wfbw6vKN4r-VnJ0p1jlUA61zh8UxxpWdmFltYd_KffFifMP2U-1iht1VHx-zrRBAlmH8dPAtdZ4kzJ_9pNBIxdfhAeZ48QBExTyGJnxT47ggLhnCKuadgRARCBSax8ZBo5JjHHLaSORYhbEeiBgugobxj8-JzjOU6J8ho_kvCjWG-GHM2UNoNgGKZA_K447CEwnfz9j4u7L5e3y2-Lqx9fvy8vrhZYVmZe6JVVjW4AG-g6t1J56LR2ja5rVZtK9pWVimoCg64C0hYddMYZ7HUGy1V5XHzc504p3m-I53bwjBQCjBQ33Kq6lLIxddm8jlpT2SZfk9GzPYopMifq2yn5AdJjq2T7p7t2Wd1c7LpbZvjDHk6Mz9y_brN_-pLfTl1fPgFYKqVd</recordid><startdate>20140101</startdate><enddate>20140101</enddate><creator>Gopal, P</creator><creator>Reddy, T. Madhusudana</creator><creator>Nagaraju, C</creator><creator>Narasimha, G</creator><scope>AAYXX</scope><scope>CITATION</scope><scope>7QO</scope><scope>8FD</scope><scope>FR3</scope><scope>P64</scope><scope>7SR</scope><scope>8BQ</scope><scope>JG9</scope></search><sort><creationdate>20140101</creationdate><title>Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples</title><author>Gopal, P ; Reddy, T. Madhusudana ; Nagaraju, C ; Narasimha, G</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c345t-2b61828ac8add9b13459229827717540f4601e7ea5c94ae26c9ad595cf25923b3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Biosensors</topic><topic>Electrochemical impedance spectroscopy</topic><topic>Enzymes</topic><topic>Laccase</topic><topic>Recovery</topic><topic>Reproducibility</topic><topic>Serums</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gopal, P</creatorcontrib><creatorcontrib>Reddy, T. Madhusudana</creatorcontrib><creatorcontrib>Nagaraju, C</creatorcontrib><creatorcontrib>Narasimha, G</creatorcontrib><collection>CrossRef</collection><collection>Biotechnology Research Abstracts</collection><collection>Technology Research Database</collection><collection>Engineering Research Database</collection><collection>Biotechnology and BioEngineering Abstracts</collection><collection>Engineered Materials Abstracts</collection><collection>METADEX</collection><collection>Materials Research Database</collection><jtitle>RSC advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gopal, P</au><au>Reddy, T. Madhusudana</au><au>Nagaraju, C</au><au>Narasimha, G</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples</atitle><jtitle>RSC advances</jtitle><date>2014-01-01</date><risdate>2014</risdate><volume>4</volume><issue>11</issue><spage>57591</spage><epage>57599</epage><pages>57591-57599</pages><issn>2046-2069</issn><eissn>2046-2069</eissn><abstract>A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) on to a glassy carbon electrode (GCE) and subsequent casting of silica sol-gel (SiSG) entrapped laccase (Lac) enzyme on to the MWCNT/GCE. The catalytic activity of laccase biosensor was found to be good enough for sensitive determination of isoprenaline (ISP) with the aid of voltammetric techniques and we have also demonstrated the detailed electrochemical redox mechanism of ISP. From the effect of the pH, we have optimized the optimum pH as 6.5, and from effect of scan rate we have evaluated the kinetic parameters, heterogeneous rate constant, charge transfer coefficient and diffusion coefficient values. Furthermore the limit of detection (LOD) and limit of quantification (LOQ) values were found to be 1.8 × 10 −7 M and 6.0 × 10 −7 M, respectively. The simultaneous determination of ISP in the presence of uric acid (UA) and ascorbic acid (AA) was successfully carried out. The surface nature of the biosensor was characterized by using electrochemical impedance spectroscopy. Finally the validation of the proposed method was verified by the recovery of injection (ISP) in serum samples and their recoveries were found to be in a satisfactory range. The proposed method was found to have good repeatability, reproducibility and stability with low relative standard deviation (RSD) values. A novel electrochemical biosensor has been developed based on the immobilization of multiwalled carbon nanotubes (MWCNT) followed by sol-gel entrapment of laccase (Lac) enzyme on to the GCE.</abstract><doi>10.1039/c4ra09989c</doi><tpages>9</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2046-2069
ispartof RSC advances, 2014-01, Vol.4 (11), p.57591-57599
issn 2046-2069
2046-2069
language eng
recordid cdi_crossref_primary_10_1039_C4RA09989C
source Royal Society Of Chemistry Journals 2008-
subjects Biosensors
Electrochemical impedance spectroscopy
Enzymes
Laccase
Recovery
Reproducibility
Serums
title Preparation, characterization and analytical application of an electrochemical laccase biosensor towards low level determination of isoprenaline in human serum samples
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-24T13%3A52%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Preparation,%20characterization%20and%20analytical%20application%20of%20an%20electrochemical%20laccase%20biosensor%20towards%20low%20level%20determination%20of%20isoprenaline%20in%20human%20serum%20samples&rft.jtitle=RSC%20advances&rft.au=Gopal,%20P&rft.date=2014-01-01&rft.volume=4&rft.issue=11&rft.spage=57591&rft.epage=57599&rft.pages=57591-57599&rft.issn=2046-2069&rft.eissn=2046-2069&rft_id=info:doi/10.1039/c4ra09989c&rft_dat=%3Cproquest_cross%3E1730085738%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=1654686865&rft_id=info:pmid/&rfr_iscdi=true