In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications

To meet the demand for biomaterials due to increasing bone defects and damage, we sought to synthesize titania–graphene nanocomposites at different sintering temperatures and then optimize them to explore their potential applications in biomaterials. The nanocomposites with higher surface area (212....

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:RSC advances 2014, Vol.4 (83), p.43951-43961
Hauptverfasser: Kavitha, K., Chunyan, W., Navaneethan, D., Rajendran, V., Valiyaveettil, Suresh, Vinoth, A.
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 43961
container_issue 83
container_start_page 43951
container_title RSC advances
container_volume 4
creator Kavitha, K.
Chunyan, W.
Navaneethan, D.
Rajendran, V.
Valiyaveettil, Suresh
Vinoth, A.
description To meet the demand for biomaterials due to increasing bone defects and damage, we sought to synthesize titania–graphene nanocomposites at different sintering temperatures and then optimize them to explore their potential applications in biomaterials. The nanocomposites with higher surface area (212.85 to 233.87 m 2 g −1 ) and mechanical strength ranging from 0.430 to 2.11 GPa were subjected to 1.5 mM simulated body fluid to confirm their bioactivity mechanisms. The non-significant toxic nature of nanocomposites in MG-63 osteoblast cell lines and controlled swelling and degradation rates indicate the suitability of these materials for biomedical applications. Moreover, the obtained percentage of mitochondrial damage, osteocalcin, osteopontin and collagen type I gene expression level in MG-63 cell line confirms that the nanocomposite sintered at 400 °C is the more optimal biomimetic material among the prepared nanocomposites. The preliminary in vivo toxicity of the nanocomposite sintered at 400 °C in zebrafish ( Danio rerio ) shows a non-toxic nature. These optimization studies will help further research and optimization of promising biomimetic materials for the repair and reconstruction of natural bone tissue.
doi_str_mv 10.1039/C4RA03964E
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1039_C4RA03964E</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1039_C4RA03964E</sourcerecordid><originalsourceid>FETCH-LOGICAL-c231t-2f59838b0218ed5f0adef4b6e6c535826fd17d30365cabf10a5f3ea3464850e3</originalsourceid><addsrcrecordid>eNpNUMFKAzEQDaJgqb34BTkLq8lmE7fHUqoWCoL0vsxuJjXSTUKSFr35D-IP-iXuoqBzeTPDvPeYR8glZ9ecifnNsnpaDKiq1QmZlKxSRcnU_PRff05mKb2woZTkpeIT8rl29Ghz9HSHDim-hogpWe8oOE2HYW976yC-UTseHj1N-aAtJuoNzdgHjJAPEQuNAZ1Gl2m2GZyFr_ePXYTwPMo6cL7zffDJ5oFqfKStH_YRwx467EcahLC3HeTBO12QMwP7hLNfnJLt3Wq7fCg2j_fr5WJTdKXguSiNnNeiblnJa9TSMNBoqlah6qSQdamM5rdaMKFkB63hDKQRCKJSVS0Ziim5-pHtok8pomlCtP3wbMNZM0ba_EUqvgH7lW7K</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications</title><source>Royal Society Of Chemistry Journals</source><creator>Kavitha, K. ; Chunyan, W. ; Navaneethan, D. ; Rajendran, V. ; Valiyaveettil, Suresh ; Vinoth, A.</creator><creatorcontrib>Kavitha, K. ; Chunyan, W. ; Navaneethan, D. ; Rajendran, V. ; Valiyaveettil, Suresh ; Vinoth, A.</creatorcontrib><description>To meet the demand for biomaterials due to increasing bone defects and damage, we sought to synthesize titania–graphene nanocomposites at different sintering temperatures and then optimize them to explore their potential applications in biomaterials. The nanocomposites with higher surface area (212.85 to 233.87 m 2 g −1 ) and mechanical strength ranging from 0.430 to 2.11 GPa were subjected to 1.5 mM simulated body fluid to confirm their bioactivity mechanisms. The non-significant toxic nature of nanocomposites in MG-63 osteoblast cell lines and controlled swelling and degradation rates indicate the suitability of these materials for biomedical applications. Moreover, the obtained percentage of mitochondrial damage, osteocalcin, osteopontin and collagen type I gene expression level in MG-63 cell line confirms that the nanocomposite sintered at 400 °C is the more optimal biomimetic material among the prepared nanocomposites. The preliminary in vivo toxicity of the nanocomposite sintered at 400 °C in zebrafish ( Danio rerio ) shows a non-toxic nature. These optimization studies will help further research and optimization of promising biomimetic materials for the repair and reconstruction of natural bone tissue.</description><identifier>ISSN: 2046-2069</identifier><identifier>EISSN: 2046-2069</identifier><identifier>DOI: 10.1039/C4RA03964E</identifier><language>eng</language><ispartof>RSC advances, 2014, Vol.4 (83), p.43951-43961</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c231t-2f59838b0218ed5f0adef4b6e6c535826fd17d30365cabf10a5f3ea3464850e3</citedby><cites>FETCH-LOGICAL-c231t-2f59838b0218ed5f0adef4b6e6c535826fd17d30365cabf10a5f3ea3464850e3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>315,782,786,4028,27932,27933,27934</link.rule.ids></links><search><creatorcontrib>Kavitha, K.</creatorcontrib><creatorcontrib>Chunyan, W.</creatorcontrib><creatorcontrib>Navaneethan, D.</creatorcontrib><creatorcontrib>Rajendran, V.</creatorcontrib><creatorcontrib>Valiyaveettil, Suresh</creatorcontrib><creatorcontrib>Vinoth, A.</creatorcontrib><title>In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications</title><title>RSC advances</title><description>To meet the demand for biomaterials due to increasing bone defects and damage, we sought to synthesize titania–graphene nanocomposites at different sintering temperatures and then optimize them to explore their potential applications in biomaterials. The nanocomposites with higher surface area (212.85 to 233.87 m 2 g −1 ) and mechanical strength ranging from 0.430 to 2.11 GPa were subjected to 1.5 mM simulated body fluid to confirm their bioactivity mechanisms. The non-significant toxic nature of nanocomposites in MG-63 osteoblast cell lines and controlled swelling and degradation rates indicate the suitability of these materials for biomedical applications. Moreover, the obtained percentage of mitochondrial damage, osteocalcin, osteopontin and collagen type I gene expression level in MG-63 cell line confirms that the nanocomposite sintered at 400 °C is the more optimal biomimetic material among the prepared nanocomposites. The preliminary in vivo toxicity of the nanocomposite sintered at 400 °C in zebrafish ( Danio rerio ) shows a non-toxic nature. These optimization studies will help further research and optimization of promising biomimetic materials for the repair and reconstruction of natural bone tissue.</description><issn>2046-2069</issn><issn>2046-2069</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNpNUMFKAzEQDaJgqb34BTkLq8lmE7fHUqoWCoL0vsxuJjXSTUKSFr35D-IP-iXuoqBzeTPDvPeYR8glZ9ecifnNsnpaDKiq1QmZlKxSRcnU_PRff05mKb2woZTkpeIT8rl29Ghz9HSHDim-hogpWe8oOE2HYW976yC-UTseHj1N-aAtJuoNzdgHjJAPEQuNAZ1Gl2m2GZyFr_ePXYTwPMo6cL7zffDJ5oFqfKStH_YRwx467EcahLC3HeTBO12QMwP7hLNfnJLt3Wq7fCg2j_fr5WJTdKXguSiNnNeiblnJa9TSMNBoqlah6qSQdamM5rdaMKFkB63hDKQRCKJSVS0Ziim5-pHtok8pomlCtP3wbMNZM0ba_EUqvgH7lW7K</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Kavitha, K.</creator><creator>Chunyan, W.</creator><creator>Navaneethan, D.</creator><creator>Rajendran, V.</creator><creator>Valiyaveettil, Suresh</creator><creator>Vinoth, A.</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2014</creationdate><title>In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications</title><author>Kavitha, K. ; Chunyan, W. ; Navaneethan, D. ; Rajendran, V. ; Valiyaveettil, Suresh ; Vinoth, A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c231t-2f59838b0218ed5f0adef4b6e6c535826fd17d30365cabf10a5f3ea3464850e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kavitha, K.</creatorcontrib><creatorcontrib>Chunyan, W.</creatorcontrib><creatorcontrib>Navaneethan, D.</creatorcontrib><creatorcontrib>Rajendran, V.</creatorcontrib><creatorcontrib>Valiyaveettil, Suresh</creatorcontrib><creatorcontrib>Vinoth, A.</creatorcontrib><collection>CrossRef</collection><jtitle>RSC advances</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kavitha, K.</au><au>Chunyan, W.</au><au>Navaneethan, D.</au><au>Rajendran, V.</au><au>Valiyaveettil, Suresh</au><au>Vinoth, A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications</atitle><jtitle>RSC advances</jtitle><date>2014</date><risdate>2014</risdate><volume>4</volume><issue>83</issue><spage>43951</spage><epage>43961</epage><pages>43951-43961</pages><issn>2046-2069</issn><eissn>2046-2069</eissn><abstract>To meet the demand for biomaterials due to increasing bone defects and damage, we sought to synthesize titania–graphene nanocomposites at different sintering temperatures and then optimize them to explore their potential applications in biomaterials. The nanocomposites with higher surface area (212.85 to 233.87 m 2 g −1 ) and mechanical strength ranging from 0.430 to 2.11 GPa were subjected to 1.5 mM simulated body fluid to confirm their bioactivity mechanisms. The non-significant toxic nature of nanocomposites in MG-63 osteoblast cell lines and controlled swelling and degradation rates indicate the suitability of these materials for biomedical applications. Moreover, the obtained percentage of mitochondrial damage, osteocalcin, osteopontin and collagen type I gene expression level in MG-63 cell line confirms that the nanocomposite sintered at 400 °C is the more optimal biomimetic material among the prepared nanocomposites. The preliminary in vivo toxicity of the nanocomposite sintered at 400 °C in zebrafish ( Danio rerio ) shows a non-toxic nature. These optimization studies will help further research and optimization of promising biomimetic materials for the repair and reconstruction of natural bone tissue.</abstract><doi>10.1039/C4RA03964E</doi><tpages>11</tpages></addata></record>
fulltext fulltext
identifier ISSN: 2046-2069
ispartof RSC advances, 2014, Vol.4 (83), p.43951-43961
issn 2046-2069
2046-2069
language eng
recordid cdi_crossref_primary_10_1039_C4RA03964E
source Royal Society Of Chemistry Journals
title In vitro gene expression and preliminary in vivo studies of temperature-dependent titania–graphene nanocomposites for bone replacement applications
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-11-30T12%3A33%3A01IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vitro%20gene%20expression%20and%20preliminary%20in%20vivo%20studies%20of%20temperature-dependent%20titania%E2%80%93graphene%20nanocomposites%20for%20bone%20replacement%20applications&rft.jtitle=RSC%20advances&rft.au=Kavitha,%20K.&rft.date=2014&rft.volume=4&rft.issue=83&rft.spage=43951&rft.epage=43961&rft.pages=43951-43961&rft.issn=2046-2069&rft.eissn=2046-2069&rft_id=info:doi/10.1039/C4RA03964E&rft_dat=%3Ccrossref%3E10_1039_C4RA03964E%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true