Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy

We show how atomic force microscopy techniques based on contact resonance (CR) can be used to measure the viscoelastic loss tangent tan δ of polymeric materials. The method does not require intermediate calculation of loss and storage moduli, calibration measurements, or use of the conventional CR t...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Macromolecules 2013-12, Vol.46 (23), p.9396-9402
Hauptverfasser: Hurley, Donna C, Campbell, Sara E, Killgore, Jason P, Cox, Lewis M, Ding, Yifu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 9402
container_issue 23
container_start_page 9396
container_title Macromolecules
container_volume 46
creator Hurley, Donna C
Campbell, Sara E
Killgore, Jason P
Cox, Lewis M
Ding, Yifu
description We show how atomic force microscopy techniques based on contact resonance (CR) can be used to measure the viscoelastic loss tangent tan δ of polymeric materials. The method does not require intermediate calculation of loss and storage moduli, calibration measurements, or use of the conventional CR tip shape parameter. We present the method’s physical concepts and sensitivity calculations for typical experimental parameters. In addition, CR experiments were performed on four homogeneous polymer samples (polystyrene, high-density polyethylene, and two commercial photostress polymers) with tan δ in the range from approximately 0.02 to 0.2. Results compare favorably to those obtained by microscale dynamic nanoindentation and macroscale dynamic mechanical analysis. These results show the potential of CR modes for nanoscale viscoelastic measurements of polymers and biomaterials.
doi_str_mv 10.1021/ma401988h
format Article
fullrecord <record><control><sourceid>acs_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1021_ma401988h</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>a350933040</sourcerecordid><originalsourceid>FETCH-LOGICAL-a259t-116004e7d62ff7c9d36f6e4b35fc0eaa85d859398113998e9cce846c2396c42c3</originalsourceid><addsrcrecordid>eNptkE9LAzEQxYMoWKsHv0EuHjys5u82OZZiVWgRpHpd4-zEbuluSpIi_fbuUvHkaWDm9948HiHXnN1xJvh96xTj1pj1CRlxLVihjdSnZMSYUIUVdnJOLlLaMMa5VnJEPpbo0j5ii12mwdP3JkHArUu5AboIKdGV676G43eT13QWuuwg01dMoXMdIF2GGtOgnObQ9pp5iMO2gRh6p93hkpx5t0149TvH5G3-sJo9FYuXx-fZdFE4oW0uOC8ZUzipS-H9BGwtS1-i-pTaA0PnjK6NttIazqW1Bi0AGlWCkLYEJUCOye3Rd3icIvpqF5vWxUPFWTVUU_1V07M3R9ZBqjZhH7s-2T_cDxGAYyQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy</title><source>American Chemical Society Journals</source><creator>Hurley, Donna C ; Campbell, Sara E ; Killgore, Jason P ; Cox, Lewis M ; Ding, Yifu</creator><creatorcontrib>Hurley, Donna C ; Campbell, Sara E ; Killgore, Jason P ; Cox, Lewis M ; Ding, Yifu</creatorcontrib><description>We show how atomic force microscopy techniques based on contact resonance (CR) can be used to measure the viscoelastic loss tangent tan δ of polymeric materials. The method does not require intermediate calculation of loss and storage moduli, calibration measurements, or use of the conventional CR tip shape parameter. We present the method’s physical concepts and sensitivity calculations for typical experimental parameters. In addition, CR experiments were performed on four homogeneous polymer samples (polystyrene, high-density polyethylene, and two commercial photostress polymers) with tan δ in the range from approximately 0.02 to 0.2. Results compare favorably to those obtained by microscale dynamic nanoindentation and macroscale dynamic mechanical analysis. These results show the potential of CR modes for nanoscale viscoelastic measurements of polymers and biomaterials.</description><identifier>ISSN: 0024-9297</identifier><identifier>EISSN: 1520-5835</identifier><identifier>DOI: 10.1021/ma401988h</identifier><language>eng</language><publisher>American Chemical Society</publisher><ispartof>Macromolecules, 2013-12, Vol.46 (23), p.9396-9402</ispartof><rights>Copyright © 2013 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a259t-116004e7d62ff7c9d36f6e4b35fc0eaa85d859398113998e9cce846c2396c42c3</citedby><cites>FETCH-LOGICAL-a259t-116004e7d62ff7c9d36f6e4b35fc0eaa85d859398113998e9cce846c2396c42c3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/ma401988h$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/ma401988h$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,780,784,2765,27076,27924,27925,56738,56788</link.rule.ids></links><search><creatorcontrib>Hurley, Donna C</creatorcontrib><creatorcontrib>Campbell, Sara E</creatorcontrib><creatorcontrib>Killgore, Jason P</creatorcontrib><creatorcontrib>Cox, Lewis M</creatorcontrib><creatorcontrib>Ding, Yifu</creatorcontrib><title>Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy</title><title>Macromolecules</title><addtitle>Macromolecules</addtitle><description>We show how atomic force microscopy techniques based on contact resonance (CR) can be used to measure the viscoelastic loss tangent tan δ of polymeric materials. The method does not require intermediate calculation of loss and storage moduli, calibration measurements, or use of the conventional CR tip shape parameter. We present the method’s physical concepts and sensitivity calculations for typical experimental parameters. In addition, CR experiments were performed on four homogeneous polymer samples (polystyrene, high-density polyethylene, and two commercial photostress polymers) with tan δ in the range from approximately 0.02 to 0.2. Results compare favorably to those obtained by microscale dynamic nanoindentation and macroscale dynamic mechanical analysis. These results show the potential of CR modes for nanoscale viscoelastic measurements of polymers and biomaterials.</description><issn>0024-9297</issn><issn>1520-5835</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><recordid>eNptkE9LAzEQxYMoWKsHv0EuHjys5u82OZZiVWgRpHpd4-zEbuluSpIi_fbuUvHkaWDm9948HiHXnN1xJvh96xTj1pj1CRlxLVihjdSnZMSYUIUVdnJOLlLaMMa5VnJEPpbo0j5ii12mwdP3JkHArUu5AboIKdGV676G43eT13QWuuwg01dMoXMdIF2GGtOgnObQ9pp5iMO2gRh6p93hkpx5t0149TvH5G3-sJo9FYuXx-fZdFE4oW0uOC8ZUzipS-H9BGwtS1-i-pTaA0PnjK6NttIazqW1Bi0AGlWCkLYEJUCOye3Rd3icIvpqF5vWxUPFWTVUU_1V07M3R9ZBqjZhH7s-2T_cDxGAYyQ</recordid><startdate>20131210</startdate><enddate>20131210</enddate><creator>Hurley, Donna C</creator><creator>Campbell, Sara E</creator><creator>Killgore, Jason P</creator><creator>Cox, Lewis M</creator><creator>Ding, Yifu</creator><general>American Chemical Society</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20131210</creationdate><title>Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy</title><author>Hurley, Donna C ; Campbell, Sara E ; Killgore, Jason P ; Cox, Lewis M ; Ding, Yifu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a259t-116004e7d62ff7c9d36f6e4b35fc0eaa85d859398113998e9cce846c2396c42c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hurley, Donna C</creatorcontrib><creatorcontrib>Campbell, Sara E</creatorcontrib><creatorcontrib>Killgore, Jason P</creatorcontrib><creatorcontrib>Cox, Lewis M</creatorcontrib><creatorcontrib>Ding, Yifu</creatorcontrib><collection>CrossRef</collection><jtitle>Macromolecules</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hurley, Donna C</au><au>Campbell, Sara E</au><au>Killgore, Jason P</au><au>Cox, Lewis M</au><au>Ding, Yifu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy</atitle><jtitle>Macromolecules</jtitle><addtitle>Macromolecules</addtitle><date>2013-12-10</date><risdate>2013</risdate><volume>46</volume><issue>23</issue><spage>9396</spage><epage>9402</epage><pages>9396-9402</pages><issn>0024-9297</issn><eissn>1520-5835</eissn><abstract>We show how atomic force microscopy techniques based on contact resonance (CR) can be used to measure the viscoelastic loss tangent tan δ of polymeric materials. The method does not require intermediate calculation of loss and storage moduli, calibration measurements, or use of the conventional CR tip shape parameter. We present the method’s physical concepts and sensitivity calculations for typical experimental parameters. In addition, CR experiments were performed on four homogeneous polymer samples (polystyrene, high-density polyethylene, and two commercial photostress polymers) with tan δ in the range from approximately 0.02 to 0.2. Results compare favorably to those obtained by microscale dynamic nanoindentation and macroscale dynamic mechanical analysis. These results show the potential of CR modes for nanoscale viscoelastic measurements of polymers and biomaterials.</abstract><pub>American Chemical Society</pub><doi>10.1021/ma401988h</doi><tpages>7</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0024-9297
ispartof Macromolecules, 2013-12, Vol.46 (23), p.9396-9402
issn 0024-9297
1520-5835
language eng
recordid cdi_crossref_primary_10_1021_ma401988h
source American Chemical Society Journals
title Measurement of Viscoelastic Loss Tangent with Contact Resonance Modes of Atomic Force Microscopy
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T03%3A44%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-acs_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Measurement%20of%20Viscoelastic%20Loss%20Tangent%20with%20Contact%20Resonance%20Modes%20of%20Atomic%20Force%20Microscopy&rft.jtitle=Macromolecules&rft.au=Hurley,%20Donna%20C&rft.date=2013-12-10&rft.volume=46&rft.issue=23&rft.spage=9396&rft.epage=9402&rft.pages=9396-9402&rft.issn=0024-9297&rft.eissn=1520-5835&rft_id=info:doi/10.1021/ma401988h&rft_dat=%3Cacs_cross%3Ea350933040%3C/acs_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true