Scanning Electrochemical Microscopy (SECM) as a Probe of Transfer Processes in Two-Phase Systems:  Theory and Experimental Applications of SECM-Induced Transfer with Arbitrary Partition Coefficients, Diffusion Coefficients, and Interfacial Kinetics

Scanning electrochemical microscopy induced transfer (SECMIT) is introduced as a new approach for probing the dynamics of partitioning of electroactive solutes between two immiscible phases. The partitioning process, initially at equilibrium, is perturbed by electrolysis of the target solute at an u...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:The journal of physical chemistry. B 1998-02, Vol.102 (9), p.1586-1598
Hauptverfasser: Barker, Anna L, Macpherson, Julie V, Slevin, Christopher J, Unwin, Patrick R
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Scanning electrochemical microscopy induced transfer (SECMIT) is introduced as a new approach for probing the dynamics of partitioning of electroactive solutes between two immiscible phases. The partitioning process, initially at equilibrium, is perturbed by electrolysis of the target solute at an ultramicroelectrode (UME) tip positioned in one phase, close to the interface with a second phase. For a particular separation between the tip and interface, the flux of soluteand hence current flowingat the UME is governed primarily by the partition coefficient of the solute, K e, the relative diffusion coefficients of the solute in the two phases, γ, and the interfacial transfer kinetics. A numerical model is developed for SECMIT under potential step chronoamperometric conditions, where the target solute is electrolyzed at the UME at a diffusion-controlled rate. When the interfacial kinetics are nonlimiting, the steady-state current is strongly dependent on the product K eγ, particularly for K eγ > 1, while for constant K eγ the corresponding chronoamperometric response depends on the individual values of K e and γ. In principle, this methodology provides a route to determining the diffusion coefficient and/or concentration of a target solute in a medium, without contact from the UME. This aspect of SECMIT is illustrated, under steady-state conditions, through studies on the transfer of (i) several types of electroactive ions between hydrogels and aqueous solutions and (ii) oxygen transfer across the interface formed between water and either 1,2-dichloroethane (DCE) or nitrobenzene (NB). The application of SECMIT to probe interfacial kinetics is illustrated through studies of cupric ion extraction and stripping between an aqueous phase and DCE containing the oxime ligand, Acorga P50 (LH).
ISSN:1520-6106
1520-5207
DOI:10.1021/jp973370r