Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors

Even a small amount of harmful liquid/gas leakage is hazardous and probably leads to extraordinarily dangerous situations. To effectively control the storage of harmful liquids/gases, the monitoring of leakage is thus highly important. Herein, we develop an indicator film that can easily respond to...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:ACS applied polymer materials 2021-08, Vol.3 (8), p.4027-4034
Hauptverfasser: Tang, Shuangxi, Guo, Linyuan, Zhu, Shicai, Ma, Liran, Tian, Yu
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4034
container_issue 8
container_start_page 4027
container_title ACS applied polymer materials
container_volume 3
creator Tang, Shuangxi
Guo, Linyuan
Zhu, Shicai
Ma, Liran
Tian, Yu
description Even a small amount of harmful liquid/gas leakage is hazardous and probably leads to extraordinarily dangerous situations. To effectively control the storage of harmful liquids/gases, the monitoring of leakage is thus highly important. Herein, we develop an indicator film that can easily respond to harmful hydrophilic liquids and gases and allow for the visual recognition of a transparency transformation involving hydrated poly­(N-isopropylacrylamide). The normalized transparency of the indicator film is 100% when it is wet and below 10% when it is triggered by hydrophilic liquids and gases. The pH paper-like indicator film responds to some harmful hydrophilic liquids and gases in the chemical laboratory, including alcohols, ketones, aldehydes, acid solutions, their corresponding vapors, and some gases. The response to hydrophilic liquids and gases by the indicator film is attributed to competition between hydrophilic molecules and poly­(N-isopropylacrylamide) in absorbing water. This work not only provides an understanding of the adsorption and diffusion of gases and liquids on surfaces but also affords promising applications for monitoring chemical industry and chemical laboratory environments, general pollution levels, and indoor air quality.
doi_str_mv 10.1021/acsapm.1c00551
format Article
fullrecord <record><control><sourceid>acs_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1021_acsapm_1c00551</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>b697229373</sourcerecordid><originalsourceid>FETCH-LOGICAL-a204t-5366f393776fb4e407442c00b88a33474fbde7b47a069d967a3f5cc41b9372c83</originalsourceid><addsrcrecordid>eNp1kD1PwzAQhi0EElXpyuwZKcFfsZMRVZRUigQDdI0udixc8oXdDP33GKUDC9O9Ot1zevUgdE9JSgmjj6ADTH1KNSFZRq_QikmuEklJdv0n36JNCEdCIsEEy9gKVW8wtT6p3FeLDy7M0OH9YJyG0-jxznV9wDamEnxv5w6XZ-PH6dN1TuPKfc_OBAyDwQeYRh_u0I2FLrSby1yjj93z-7ZMqteX_fapSoARcUoyLqXlBVdK2ka0gighWCze5DlwLpSwjWlVIxQQWZhCKuA201rQJjJM53yN0uWv9mMIvrX15F0P_lxTUv_qqBcd9UVHBB4WIO7r4zj7Idb77_gHdaNhLw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors</title><source>ACS Publications</source><creator>Tang, Shuangxi ; Guo, Linyuan ; Zhu, Shicai ; Ma, Liran ; Tian, Yu</creator><creatorcontrib>Tang, Shuangxi ; Guo, Linyuan ; Zhu, Shicai ; Ma, Liran ; Tian, Yu</creatorcontrib><description>Even a small amount of harmful liquid/gas leakage is hazardous and probably leads to extraordinarily dangerous situations. To effectively control the storage of harmful liquids/gases, the monitoring of leakage is thus highly important. Herein, we develop an indicator film that can easily respond to harmful hydrophilic liquids and gases and allow for the visual recognition of a transparency transformation involving hydrated poly­(N-isopropylacrylamide). The normalized transparency of the indicator film is 100% when it is wet and below 10% when it is triggered by hydrophilic liquids and gases. The pH paper-like indicator film responds to some harmful hydrophilic liquids and gases in the chemical laboratory, including alcohols, ketones, aldehydes, acid solutions, their corresponding vapors, and some gases. The response to hydrophilic liquids and gases by the indicator film is attributed to competition between hydrophilic molecules and poly­(N-isopropylacrylamide) in absorbing water. This work not only provides an understanding of the adsorption and diffusion of gases and liquids on surfaces but also affords promising applications for monitoring chemical industry and chemical laboratory environments, general pollution levels, and indoor air quality.</description><identifier>ISSN: 2637-6105</identifier><identifier>EISSN: 2637-6105</identifier><identifier>DOI: 10.1021/acsapm.1c00551</identifier><language>eng</language><publisher>American Chemical Society</publisher><ispartof>ACS applied polymer materials, 2021-08, Vol.3 (8), p.4027-4034</ispartof><rights>2021 American Chemical Society</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-a204t-5366f393776fb4e407442c00b88a33474fbde7b47a069d967a3f5cc41b9372c83</citedby><cites>FETCH-LOGICAL-a204t-5366f393776fb4e407442c00b88a33474fbde7b47a069d967a3f5cc41b9372c83</cites><orcidid>0000-0001-7742-5611 ; 0000-0002-7186-6659</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://pubs.acs.org/doi/pdf/10.1021/acsapm.1c00551$$EPDF$$P50$$Gacs$$H</linktopdf><linktohtml>$$Uhttps://pubs.acs.org/doi/10.1021/acsapm.1c00551$$EHTML$$P50$$Gacs$$H</linktohtml><link.rule.ids>314,778,782,2754,27063,27911,27912,56725,56775</link.rule.ids></links><search><creatorcontrib>Tang, Shuangxi</creatorcontrib><creatorcontrib>Guo, Linyuan</creatorcontrib><creatorcontrib>Zhu, Shicai</creatorcontrib><creatorcontrib>Ma, Liran</creatorcontrib><creatorcontrib>Tian, Yu</creatorcontrib><title>Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors</title><title>ACS applied polymer materials</title><addtitle>ACS Appl. Polym. Mater</addtitle><description>Even a small amount of harmful liquid/gas leakage is hazardous and probably leads to extraordinarily dangerous situations. To effectively control the storage of harmful liquids/gases, the monitoring of leakage is thus highly important. Herein, we develop an indicator film that can easily respond to harmful hydrophilic liquids and gases and allow for the visual recognition of a transparency transformation involving hydrated poly­(N-isopropylacrylamide). The normalized transparency of the indicator film is 100% when it is wet and below 10% when it is triggered by hydrophilic liquids and gases. The pH paper-like indicator film responds to some harmful hydrophilic liquids and gases in the chemical laboratory, including alcohols, ketones, aldehydes, acid solutions, their corresponding vapors, and some gases. The response to hydrophilic liquids and gases by the indicator film is attributed to competition between hydrophilic molecules and poly­(N-isopropylacrylamide) in absorbing water. This work not only provides an understanding of the adsorption and diffusion of gases and liquids on surfaces but also affords promising applications for monitoring chemical industry and chemical laboratory environments, general pollution levels, and indoor air quality.</description><issn>2637-6105</issn><issn>2637-6105</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNp1kD1PwzAQhi0EElXpyuwZKcFfsZMRVZRUigQDdI0udixc8oXdDP33GKUDC9O9Ot1zevUgdE9JSgmjj6ADTH1KNSFZRq_QikmuEklJdv0n36JNCEdCIsEEy9gKVW8wtT6p3FeLDy7M0OH9YJyG0-jxznV9wDamEnxv5w6XZ-PH6dN1TuPKfc_OBAyDwQeYRh_u0I2FLrSby1yjj93z-7ZMqteX_fapSoARcUoyLqXlBVdK2ka0gighWCze5DlwLpSwjWlVIxQQWZhCKuA201rQJjJM53yN0uWv9mMIvrX15F0P_lxTUv_qqBcd9UVHBB4WIO7r4zj7Idb77_gHdaNhLw</recordid><startdate>20210813</startdate><enddate>20210813</enddate><creator>Tang, Shuangxi</creator><creator>Guo, Linyuan</creator><creator>Zhu, Shicai</creator><creator>Ma, Liran</creator><creator>Tian, Yu</creator><general>American Chemical Society</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-7742-5611</orcidid><orcidid>https://orcid.org/0000-0002-7186-6659</orcidid></search><sort><creationdate>20210813</creationdate><title>Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors</title><author>Tang, Shuangxi ; Guo, Linyuan ; Zhu, Shicai ; Ma, Liran ; Tian, Yu</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a204t-5366f393776fb4e407442c00b88a33474fbde7b47a069d967a3f5cc41b9372c83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Tang, Shuangxi</creatorcontrib><creatorcontrib>Guo, Linyuan</creatorcontrib><creatorcontrib>Zhu, Shicai</creatorcontrib><creatorcontrib>Ma, Liran</creatorcontrib><creatorcontrib>Tian, Yu</creatorcontrib><collection>CrossRef</collection><jtitle>ACS applied polymer materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Tang, Shuangxi</au><au>Guo, Linyuan</au><au>Zhu, Shicai</au><au>Ma, Liran</au><au>Tian, Yu</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors</atitle><jtitle>ACS applied polymer materials</jtitle><addtitle>ACS Appl. Polym. Mater</addtitle><date>2021-08-13</date><risdate>2021</risdate><volume>3</volume><issue>8</issue><spage>4027</spage><epage>4034</epage><pages>4027-4034</pages><issn>2637-6105</issn><eissn>2637-6105</eissn><abstract>Even a small amount of harmful liquid/gas leakage is hazardous and probably leads to extraordinarily dangerous situations. To effectively control the storage of harmful liquids/gases, the monitoring of leakage is thus highly important. Herein, we develop an indicator film that can easily respond to harmful hydrophilic liquids and gases and allow for the visual recognition of a transparency transformation involving hydrated poly­(N-isopropylacrylamide). The normalized transparency of the indicator film is 100% when it is wet and below 10% when it is triggered by hydrophilic liquids and gases. The pH paper-like indicator film responds to some harmful hydrophilic liquids and gases in the chemical laboratory, including alcohols, ketones, aldehydes, acid solutions, their corresponding vapors, and some gases. The response to hydrophilic liquids and gases by the indicator film is attributed to competition between hydrophilic molecules and poly­(N-isopropylacrylamide) in absorbing water. This work not only provides an understanding of the adsorption and diffusion of gases and liquids on surfaces but also affords promising applications for monitoring chemical industry and chemical laboratory environments, general pollution levels, and indoor air quality.</abstract><pub>American Chemical Society</pub><doi>10.1021/acsapm.1c00551</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0001-7742-5611</orcidid><orcidid>https://orcid.org/0000-0002-7186-6659</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2637-6105
ispartof ACS applied polymer materials, 2021-08, Vol.3 (8), p.4027-4034
issn 2637-6105
2637-6105
language eng
recordid cdi_crossref_primary_10_1021_acsapm_1c00551
source ACS Publications
title Paper-Like Visual Indicator Films for Harmful Hydrophilic Liquids and Vapors
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T23%3A18%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-acs_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Paper-Like%20Visual%20Indicator%20Films%20for%20Harmful%20Hydrophilic%20Liquids%20and%20Vapors&rft.jtitle=ACS%20applied%20polymer%20materials&rft.au=Tang,%20Shuangxi&rft.date=2021-08-13&rft.volume=3&rft.issue=8&rft.spage=4027&rft.epage=4034&rft.pages=4027-4034&rft.issn=2637-6105&rft.eissn=2637-6105&rft_id=info:doi/10.1021/acsapm.1c00551&rft_dat=%3Cacs_cross%3Eb697229373%3C/acs_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true