A Gas Ion Source for Radiocarbon Measurements at 200 kV
The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A...
Gespeichert in:
Veröffentlicht in: | Radiocarbon 2007, Vol.49 (2), p.307-314 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 314 |
---|---|
container_issue | 2 |
container_start_page | 307 |
container_title | Radiocarbon |
container_volume | 49 |
creator | Ruff, M Wacker, L Gäggeler, H W Suter, M Synal, H-A Szidat, S |
description | The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3–30 μg carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of 14C/12C could be repeated within statistical errors to better than 1.0% and the 13C/12C ratios to better than 0.2%. The blank was |
doi_str_mv | 10.1017/S0033822200042235 |
format | Article |
fullrecord | <record><control><sourceid>cambridge_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1017_S0033822200042235</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cupid>10_1017_S0033822200042235</cupid><sourcerecordid>10_1017_S0033822200042235</sourcerecordid><originalsourceid>FETCH-LOGICAL-c428t-c531b1f797402df8208da1370e920b2a3f45e3773153c335d58540f140acb7473</originalsourceid><addsrcrecordid>eNp9kE1LAzEQhoMouFZ_gLdcPK5OMonJHkvRWqgIVr0us9lEtra7Jdke_Pfu0uJF8DQw78fwDGPXAm4FCHO3AkC0UkoAUFKiPmGZKJTOtdH6lGWjnI_6ObtIaQ0gxb01GTNTPqfEF13LV90-Os9DF_kr1U3nKFbD-tlT2ke_9W2fOPV8uMC_Pi7ZWaBN8lfHOWHvjw9vs6d8-TJfzKbL3Clp-9xpFJUIpjAKZB2sBFuTQAO-kFBJwqC0R2NQaHSIutZWKwhCAbnKKIMTJg69LnYpRR_KXWy2FL9LAeVIXv4hHzI3h8yOkqNNiNS6Jv0GJaC2qIrBh8du2laxqT99uR5-0A48_7T_ABfAY6Y</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Gas Ion Source for Radiocarbon Measurements at 200 kV</title><source>Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals</source><source>Free Full-Text Journals in Chemistry</source><source>Cambridge University Press Journals Complete</source><creator>Ruff, M ; Wacker, L ; Gäggeler, H W ; Suter, M ; Synal, H-A ; Szidat, S</creator><creatorcontrib>Ruff, M ; Wacker, L ; Gäggeler, H W ; Suter, M ; Synal, H-A ; Szidat, S</creatorcontrib><description>The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3–30 μg carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of 14C/12C could be repeated within statistical errors to better than 1.0% and the 13C/12C ratios to better than 0.2%. The blank was <1 pMC.</description><identifier>ISSN: 0033-8222</identifier><identifier>EISSN: 1945-5755</identifier><identifier>DOI: 10.1017/S0033822200042235</identifier><language>eng</language><publisher>New York, US: Cambridge University Press</publisher><subject>Earth sciences ; Earth, ocean, space ; Exact sciences and technology ; Geochronology ; Isotope geochemistry. Geochronology ; Measurement ; Methodology</subject><ispartof>Radiocarbon, 2007, Vol.49 (2), p.307-314</ispartof><rights>Copyright © 2007 by the Arizona Board of Regents on behalf of the University of Arizona</rights><rights>2008 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c428t-c531b1f797402df8208da1370e920b2a3f45e3773153c335d58540f140acb7473</citedby><cites>FETCH-LOGICAL-c428t-c531b1f797402df8208da1370e920b2a3f45e3773153c335d58540f140acb7473</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://www.cambridge.org/core/product/identifier/S0033822200042235/type/journal_article$$EHTML$$P50$$Gcambridge$$H</linktohtml><link.rule.ids>164,309,310,314,776,780,785,786,4010,4036,4037,23909,23910,25118,27900,27901,27902,55603</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=20358349$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Ruff, M</creatorcontrib><creatorcontrib>Wacker, L</creatorcontrib><creatorcontrib>Gäggeler, H W</creatorcontrib><creatorcontrib>Suter, M</creatorcontrib><creatorcontrib>Synal, H-A</creatorcontrib><creatorcontrib>Szidat, S</creatorcontrib><title>A Gas Ion Source for Radiocarbon Measurements at 200 kV</title><title>Radiocarbon</title><addtitle>Radiocarbon</addtitle><description>The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3–30 μg carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of 14C/12C could be repeated within statistical errors to better than 1.0% and the 13C/12C ratios to better than 0.2%. The blank was <1 pMC.</description><subject>Earth sciences</subject><subject>Earth, ocean, space</subject><subject>Exact sciences and technology</subject><subject>Geochronology</subject><subject>Isotope geochemistry. Geochronology</subject><subject>Measurement</subject><subject>Methodology</subject><issn>0033-8222</issn><issn>1945-5755</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2007</creationdate><recordtype>article</recordtype><recordid>eNp9kE1LAzEQhoMouFZ_gLdcPK5OMonJHkvRWqgIVr0us9lEtra7Jdke_Pfu0uJF8DQw78fwDGPXAm4FCHO3AkC0UkoAUFKiPmGZKJTOtdH6lGWjnI_6ObtIaQ0gxb01GTNTPqfEF13LV90-Os9DF_kr1U3nKFbD-tlT2ke_9W2fOPV8uMC_Pi7ZWaBN8lfHOWHvjw9vs6d8-TJfzKbL3Clp-9xpFJUIpjAKZB2sBFuTQAO-kFBJwqC0R2NQaHSIutZWKwhCAbnKKIMTJg69LnYpRR_KXWy2FL9LAeVIXv4hHzI3h8yOkqNNiNS6Jv0GJaC2qIrBh8du2laxqT99uR5-0A48_7T_ABfAY6Y</recordid><startdate>2007</startdate><enddate>2007</enddate><creator>Ruff, M</creator><creator>Wacker, L</creator><creator>Gäggeler, H W</creator><creator>Suter, M</creator><creator>Synal, H-A</creator><creator>Szidat, S</creator><general>Cambridge University Press</general><general>University of Arizona</general><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2007</creationdate><title>A Gas Ion Source for Radiocarbon Measurements at 200 kV</title><author>Ruff, M ; Wacker, L ; Gäggeler, H W ; Suter, M ; Synal, H-A ; Szidat, S</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c428t-c531b1f797402df8208da1370e920b2a3f45e3773153c335d58540f140acb7473</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2007</creationdate><topic>Earth sciences</topic><topic>Earth, ocean, space</topic><topic>Exact sciences and technology</topic><topic>Geochronology</topic><topic>Isotope geochemistry. Geochronology</topic><topic>Measurement</topic><topic>Methodology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ruff, M</creatorcontrib><creatorcontrib>Wacker, L</creatorcontrib><creatorcontrib>Gäggeler, H W</creatorcontrib><creatorcontrib>Suter, M</creatorcontrib><creatorcontrib>Synal, H-A</creatorcontrib><creatorcontrib>Szidat, S</creatorcontrib><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Radiocarbon</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ruff, M</au><au>Wacker, L</au><au>Gäggeler, H W</au><au>Suter, M</au><au>Synal, H-A</au><au>Szidat, S</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Gas Ion Source for Radiocarbon Measurements at 200 kV</atitle><jtitle>Radiocarbon</jtitle><addtitle>Radiocarbon</addtitle><date>2007</date><risdate>2007</risdate><volume>49</volume><issue>2</issue><spage>307</spage><epage>314</epage><pages>307-314</pages><issn>0033-8222</issn><eissn>1945-5755</eissn><abstract>The novel tabletop miniaturized radiocarbon dating system (MICADAS) at ETH Zurich features a hybrid Cs sputter negative ion source for the measurement of solid graphite and gaseous CO2 samples. The source produces stable currents of up to 6 μA C− out of gaseous samples with an efficiency of 3–6%. A gas feeding system has been set up that enables constant dosing of CO2 into the Cs sputter ion source and ensures stable measuring conditions. The system is based on a syringe in which CO2 gas is mixed with He and then pressed continuously into the ion source at a constant flow rate. Minimized volumes allow feeding samples of 3–30 μg carbon quantitatively into the ion source. In order to test the performance of the system, several standards and blanks have successfully been measured. The ratios of 14C/12C could be repeated within statistical errors to better than 1.0% and the 13C/12C ratios to better than 0.2%. The blank was <1 pMC.</abstract><cop>New York, US</cop><pub>Cambridge University Press</pub><doi>10.1017/S0033822200042235</doi><tpages>8</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0033-8222 |
ispartof | Radiocarbon, 2007, Vol.49 (2), p.307-314 |
issn | 0033-8222 1945-5755 |
language | eng |
recordid | cdi_crossref_primary_10_1017_S0033822200042235 |
source | Elektronische Zeitschriftenbibliothek - Frei zugängliche E-Journals; Free Full-Text Journals in Chemistry; Cambridge University Press Journals Complete |
subjects | Earth sciences Earth, ocean, space Exact sciences and technology Geochronology Isotope geochemistry. Geochronology Measurement Methodology |
title | A Gas Ion Source for Radiocarbon Measurements at 200 kV |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-21T16%3A47%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cambridge_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Gas%20Ion%20Source%20for%20Radiocarbon%20Measurements%20at%20200%20kV&rft.jtitle=Radiocarbon&rft.au=Ruff,%20M&rft.date=2007&rft.volume=49&rft.issue=2&rft.spage=307&rft.epage=314&rft.pages=307-314&rft.issn=0033-8222&rft.eissn=1945-5755&rft_id=info:doi/10.1017/S0033822200042235&rft_dat=%3Ccambridge_cross%3E10_1017_S0033822200042235%3C/cambridge_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_cupid=10_1017_S0033822200042235&rfr_iscdi=true |