Me-too validation study for in vitro skin irritation test with a reconstructed human epidermis model, KeraSkin™ for OECD test guideline 439

We conducted a me-too validation study to confirm the reproducibility, reliability, and predictive capacity of KeraSkin™ skin irritation test (SIT) as a me-too method of OECD TG 439. With 20 reference chemicals, within-laboratory reproducibility (WLR) of KeraSkin™ SIT in the decision of irritant or...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Regulatory toxicology and pharmacology 2020-11, Vol.117, p.104725, Article 104725
Hauptverfasser: Han, Juhee, Kim, Seolyeong, Lee, Su-Hyun, Kim, Jin-Sik, Chang, Yu Jin, Jeong, Tae-Cheon, Kang, Mi-Jeong, Kim, Tae-Sung, Yoon, Hae Seong, Lee, Ga Young, Bae, SeungJin, Lim, Kyung-Min
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:We conducted a me-too validation study to confirm the reproducibility, reliability, and predictive capacity of KeraSkin™ skin irritation test (SIT) as a me-too method of OECD TG 439. With 20 reference chemicals, within-laboratory reproducibility (WLR) of KeraSkin™ SIT in the decision of irritant or non-irritant was 100%, 100%, and 95% while between-laboratory reproducibility (BLR) was 100%, which met the criteria of performance standard (PS, WLR≥90%, BLR≥80%). WLR and BLR were further confirmed with intra-class correlation (ICC, coefficients >0.950). WLR and BLR in raw data (viability) were also shown with a scatter plot and Bland-Altman plot. Comparison with existing VRMs with Bland-Altman plot, ICC and kappa statistics confirmed the compatibility of KeraSkin™ SIT with OECD TG 439. The predictive capacity of KeraSkin™ SIT was estimated with 20 reference chemicals (the sensitivity of 98.9%, the specificity of 70%, and the accuracy of 84.4%) and additional 46 chemicals (for 66 chemicals [20 + 46 chemicals, the sensitivity, specificity and accuracy: 95.2%, 82.2% and 86.4%]). The receiver operating characteristic (ROC) analysis suggested a potential improvement of the predictive capacity, especially sensitivity, when changing cut-off (50% → 60–75%). Collectively, the me-too validation study demonstrated that KeraSkin™ SIT can be a new me-too method for OECD TG 439. •Reproducibility and predictive capacity of KeraSkin™ SIT, a me-too test of OECD TG 439, were assessed.•The statistical analysis of WLR and BLR for 20 chemicals supports the reproducibility of KeraSkin™ SIT.•Comparison of KeraSkin™ SIT with existing VRMs of OECD TG 439 demonstrated a high level of agreements.•Predictive capacity of KeraSkin™ SIT was further tested with 66 chemicals.
ISSN:0273-2300
1096-0295
DOI:10.1016/j.yrtph.2020.104725