Corrosion and biological study on biofunctionalized porous coating on titanium produced by plasma electrolytic oxidation
Upon implantation of biomaterials in human body, the risk for electrochemical corrosion within the surrounding environment becomes a critical factor affecting implant biocompatibility. This study endeavors to develop a biofunctionalized and corrosion-resistant TiO2/hydroxyapatite coating using a cos...
Gespeichert in:
Veröffentlicht in: | Colloids and surfaces. A, Physicochemical and engineering aspects Physicochemical and engineering aspects, 2024-05, Vol.688, p.133567, Article 133567 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Upon implantation of biomaterials in human body, the risk for electrochemical corrosion within the surrounding environment becomes a critical factor affecting implant biocompatibility. This study endeavors to develop a biofunctionalized and corrosion-resistant TiO2/hydroxyapatite coating using a cost-effective one-step plasma electrolytic oxidation (PEO) process. Initially, magnesium and zinc substituted hydroxyapatite (HA) particles were synthesized to enhance bioactivity and antibacterial properties compared to pure HA. The synthesized particles underwent characterization using X-ray diffraction (XRD) and field emission scanning electron microscopy (FE-SEM). Subsequently, these synthesized particles were utilized in the Plasma Electrolytic Oxidation (PEO) coating process. Polarization and electrochemical impedance spectroscopy (EIS) tests, in addition to bioactivity and antibacterial activity assessments, were conducted to examine the corrosion resistance and biological response of the coatings. The results of biological tests on particle-containing PEO coatings on titanium demonstrated a significant improvement in the bioactivity and antibacterial activity of the biofunctionalized coatings caused by ion-substituted HA particles. Furthermore, polarization and EIS results indicated superior corrosion resistance in the biofunctionalized coatings. Electrochemical tests after one week of immersion in simulated body fluid (SBF) revealed the positive influence of apatite formation on the long-term corrosion behavior of coatings with ion-substituted particles.
[Display omitted]
•Successful incorporation of Mg and Zn-substituted HA particles in the PEO coating.•Development of a biofunctionalized PEO coating using inexpensive DC power source.•A biofunctionalized coating improves corrosion resistance and biological response.•Improved long-term corrosion resistance of the PEO coating. |
---|---|
ISSN: | 0927-7757 1873-4359 |
DOI: | 10.1016/j.colsurfa.2024.133567 |