Direct and Distributed Strain Measurements Inside a Shotcrete Lining: Concept and Realisation

This paper introduces the successful implementation of a fibre-optic sensing system for direct and distributed strain measurement within the shotcrete lining of a conventional tunnel drive. The shotcrete lining of the top-heading and the invert are equipped with two layers (rock side and cavity side...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Rock mechanics and rock engineering 2020-02, Vol.53 (2), p.641-652
Hauptverfasser: Wagner, Lukas, Kluckner, Alexander, Monsberger, Christoph Martin, Wolf, Petra, Prall, Karoline, Schubert, Wulf, Lienhart, Werner
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:This paper introduces the successful implementation of a fibre-optic sensing system for direct and distributed strain measurement within the shotcrete lining of a conventional tunnel drive. The shotcrete lining of the top-heading and the invert are equipped with two layers (rock side and cavity side) of fibre-optic sensing cables installed in circumferential and longitudinal direction. All cables are measured autonomously for several weeks to capture the strain evolution inside the lining from the day of the construction to a posterior, well-hardened state. An additional follow-up measurement is conducted 2 months afterwards. The measurements enable an assessment of the strain distribution inside the lining with a spatial resolution in the range of some centimetres and a measurement resolution of up to 1 µm/m. Besides the conventional monitoring targets used for displacement recordings, measurement equipment like strain gages and pressure cells are also installed in the cross-section under investigation. Back-calculated strain from absolute displacements and the readings from the strain gages show good agreement with the results of the conducted fibre-optic measurements and verify the suitability of the used system.
ISSN:0723-2632
1434-453X
DOI:10.1007/s00603-019-01923-4