Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air

To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH con...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:International archives of occupational and environmental health 1998-11, Vol.71 (8), p.533-536
Hauptverfasser: BRANISTEANU, R, AIKING, H
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 536
container_issue 8
container_start_page 533
container_title International archives of occupational and environmental health
container_volume 71
creator BRANISTEANU, R
AIKING, H
description To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter. Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (< 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (
doi_str_mv 10.1007/s004200050319
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_s004200050319</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>9860161</sourcerecordid><originalsourceid>FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</originalsourceid><addsrcrecordid>eNpVkEtLxDAUhYMo4zi6dClk4bZ682jSLmUYHzDgRlcuym2aYqVNStIO9t_bYQbF1T3c7-MsDiHXDO4YgL6PAJIDQAqC5SdkyaTgCeNSnZIlCAkJMMHOyUWMXwBMKy0WZJFnCphiS_Kx-e59HIOlg6e9byczmbYxFIPvcJjD51QFbzCU3kXaOOqNGfuZeIct3dkQx0jHUKKj1u2a4F1n3TAjbMIlOauxjfbqeFfk_XHztn5Otq9PL-uHbWIE00OCKSAvUyilEgK4kqbOQYAUmts607mqwNQytXmGIgWeYQagMrH_ADeIYkWSQ68JPsZg66IPTYdhKhgU-42KfxvN_s3B78eys9WvfRxl5rdHjtFgWwd0pol_pYqrjGvxA5RabpQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>BRANISTEANU, R ; AIKING, H</creator><creatorcontrib>BRANISTEANU, R ; AIKING, H</creatorcontrib><description>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter. Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (&lt; 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (&lt;3 microm). The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</description><identifier>ISSN: 0340-0131</identifier><identifier>EISSN: 1432-1246</identifier><identifier>DOI: 10.1007/s004200050319</identifier><identifier>PMID: 9860161</identifier><identifier>CODEN: IAEHDW</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Air Pollutants - analysis ; Air Pollutants, Occupational - analysis ; Applied sciences ; Atmospheric pollution ; Chromatography, High Pressure Liquid ; Cities ; Coal ; Dust ; Exact sciences and technology ; Humans ; Indoor pollution and occupational exposure ; Occupational Exposure - analysis ; Particle Size ; Pollution ; Polycyclic Aromatic Hydrocarbons - analysis ; Power Plants ; Romania</subject><ispartof>International archives of occupational and environmental health, 1998-11, Vol.71 (8), p.533-536</ispartof><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=1626827$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9860161$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>BRANISTEANU, R</creatorcontrib><creatorcontrib>AIKING, H</creatorcontrib><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><title>International archives of occupational and environmental health</title><addtitle>Int Arch Occup Environ Health</addtitle><description>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter. Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (&lt; 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (&lt;3 microm). The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</description><subject>Air Pollutants - analysis</subject><subject>Air Pollutants, Occupational - analysis</subject><subject>Applied sciences</subject><subject>Atmospheric pollution</subject><subject>Chromatography, High Pressure Liquid</subject><subject>Cities</subject><subject>Coal</subject><subject>Dust</subject><subject>Exact sciences and technology</subject><subject>Humans</subject><subject>Indoor pollution and occupational exposure</subject><subject>Occupational Exposure - analysis</subject><subject>Particle Size</subject><subject>Pollution</subject><subject>Polycyclic Aromatic Hydrocarbons - analysis</subject><subject>Power Plants</subject><subject>Romania</subject><issn>0340-0131</issn><issn>1432-1246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkEtLxDAUhYMo4zi6dClk4bZ682jSLmUYHzDgRlcuym2aYqVNStIO9t_bYQbF1T3c7-MsDiHXDO4YgL6PAJIDQAqC5SdkyaTgCeNSnZIlCAkJMMHOyUWMXwBMKy0WZJFnCphiS_Kx-e59HIOlg6e9byczmbYxFIPvcJjD51QFbzCU3kXaOOqNGfuZeIct3dkQx0jHUKKj1u2a4F1n3TAjbMIlOauxjfbqeFfk_XHztn5Otq9PL-uHbWIE00OCKSAvUyilEgK4kqbOQYAUmts607mqwNQytXmGIgWeYQagMrH_ADeIYkWSQ68JPsZg66IPTYdhKhgU-42KfxvN_s3B78eys9WvfRxl5rdHjtFgWwd0pol_pYqrjGvxA5RabpQ</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>BRANISTEANU, R</creator><creator>AIKING, H</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19981101</creationdate><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><author>BRANISTEANU, R ; AIKING, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Air Pollutants - analysis</topic><topic>Air Pollutants, Occupational - analysis</topic><topic>Applied sciences</topic><topic>Atmospheric pollution</topic><topic>Chromatography, High Pressure Liquid</topic><topic>Cities</topic><topic>Coal</topic><topic>Dust</topic><topic>Exact sciences and technology</topic><topic>Humans</topic><topic>Indoor pollution and occupational exposure</topic><topic>Occupational Exposure - analysis</topic><topic>Particle Size</topic><topic>Pollution</topic><topic>Polycyclic Aromatic Hydrocarbons - analysis</topic><topic>Power Plants</topic><topic>Romania</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BRANISTEANU, R</creatorcontrib><creatorcontrib>AIKING, H</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>International archives of occupational and environmental health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BRANISTEANU, R</au><au>AIKING, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</atitle><jtitle>International archives of occupational and environmental health</jtitle><addtitle>Int Arch Occup Environ Health</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>71</volume><issue>8</issue><spage>533</spage><epage>536</epage><pages>533-536</pages><issn>0340-0131</issn><eissn>1432-1246</eissn><coden>IAEHDW</coden><abstract>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter. Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (&lt; 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (&lt;3 microm). The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>9860161</pmid><doi>10.1007/s004200050319</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-0131
ispartof International archives of occupational and environmental health, 1998-11, Vol.71 (8), p.533-536
issn 0340-0131
1432-1246
language eng
recordid cdi_crossref_primary_10_1007_s004200050319
source MEDLINE; SpringerLink Journals
subjects Air Pollutants - analysis
Air Pollutants, Occupational - analysis
Applied sciences
Atmospheric pollution
Chromatography, High Pressure Liquid
Cities
Coal
Dust
Exact sciences and technology
Humans
Indoor pollution and occupational exposure
Occupational Exposure - analysis
Particle Size
Pollution
Polycyclic Aromatic Hydrocarbons - analysis
Power Plants
Romania
title Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T14%3A51%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exposure%20to%20polycyclic%20aromatic%20hydrocarbons%20in%20occupational%20versus%20urban%20environmental%20air&rft.jtitle=International%20archives%20of%20occupational%20and%20environmental%20health&rft.au=BRANISTEANU,%20R&rft.date=1998-11-01&rft.volume=71&rft.issue=8&rft.spage=533&rft.epage=536&rft.pages=533-536&rft.issn=0340-0131&rft.eissn=1432-1246&rft.coden=IAEHDW&rft_id=info:doi/10.1007/s004200050319&rft_dat=%3Cpubmed_cross%3E9860161%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/9860161&rfr_iscdi=true