Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air
To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby. The analysis of SPM for PAH con...
Gespeichert in:
Veröffentlicht in: | International archives of occupational and environmental health 1998-11, Vol.71 (8), p.533-536 |
---|---|
Hauptverfasser: | , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 536 |
---|---|
container_issue | 8 |
container_start_page | 533 |
container_title | International archives of occupational and environmental health |
container_volume | 71 |
creator | BRANISTEANU, R AIKING, H |
description | To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby.
The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter.
Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (< 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles ( |
doi_str_mv | 10.1007/s004200050319 |
format | Article |
fullrecord | <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_s004200050319</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>9860161</sourcerecordid><originalsourceid>FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</originalsourceid><addsrcrecordid>eNpVkEtLxDAUhYMo4zi6dClk4bZ682jSLmUYHzDgRlcuym2aYqVNStIO9t_bYQbF1T3c7-MsDiHXDO4YgL6PAJIDQAqC5SdkyaTgCeNSnZIlCAkJMMHOyUWMXwBMKy0WZJFnCphiS_Kx-e59HIOlg6e9byczmbYxFIPvcJjD51QFbzCU3kXaOOqNGfuZeIct3dkQx0jHUKKj1u2a4F1n3TAjbMIlOauxjfbqeFfk_XHztn5Otq9PL-uHbWIE00OCKSAvUyilEgK4kqbOQYAUmts607mqwNQytXmGIgWeYQagMrH_ADeIYkWSQ68JPsZg66IPTYdhKhgU-42KfxvN_s3B78eys9WvfRxl5rdHjtFgWwd0pol_pYqrjGvxA5RabpQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>BRANISTEANU, R ; AIKING, H</creator><creatorcontrib>BRANISTEANU, R ; AIKING, H</creatorcontrib><description>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby.
The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter.
Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (< 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (<3 microm).
The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</description><identifier>ISSN: 0340-0131</identifier><identifier>EISSN: 1432-1246</identifier><identifier>DOI: 10.1007/s004200050319</identifier><identifier>PMID: 9860161</identifier><identifier>CODEN: IAEHDW</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Air Pollutants - analysis ; Air Pollutants, Occupational - analysis ; Applied sciences ; Atmospheric pollution ; Chromatography, High Pressure Liquid ; Cities ; Coal ; Dust ; Exact sciences and technology ; Humans ; Indoor pollution and occupational exposure ; Occupational Exposure - analysis ; Particle Size ; Pollution ; Polycyclic Aromatic Hydrocarbons - analysis ; Power Plants ; Romania</subject><ispartof>International archives of occupational and environmental health, 1998-11, Vol.71 (8), p.533-536</ispartof><rights>1999 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=1626827$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/9860161$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>BRANISTEANU, R</creatorcontrib><creatorcontrib>AIKING, H</creatorcontrib><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><title>International archives of occupational and environmental health</title><addtitle>Int Arch Occup Environ Health</addtitle><description>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby.
The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter.
Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (< 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (<3 microm).
The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</description><subject>Air Pollutants - analysis</subject><subject>Air Pollutants, Occupational - analysis</subject><subject>Applied sciences</subject><subject>Atmospheric pollution</subject><subject>Chromatography, High Pressure Liquid</subject><subject>Cities</subject><subject>Coal</subject><subject>Dust</subject><subject>Exact sciences and technology</subject><subject>Humans</subject><subject>Indoor pollution and occupational exposure</subject><subject>Occupational Exposure - analysis</subject><subject>Particle Size</subject><subject>Pollution</subject><subject>Polycyclic Aromatic Hydrocarbons - analysis</subject><subject>Power Plants</subject><subject>Romania</subject><issn>0340-0131</issn><issn>1432-1246</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpVkEtLxDAUhYMo4zi6dClk4bZ682jSLmUYHzDgRlcuym2aYqVNStIO9t_bYQbF1T3c7-MsDiHXDO4YgL6PAJIDQAqC5SdkyaTgCeNSnZIlCAkJMMHOyUWMXwBMKy0WZJFnCphiS_Kx-e59HIOlg6e9byczmbYxFIPvcJjD51QFbzCU3kXaOOqNGfuZeIct3dkQx0jHUKKj1u2a4F1n3TAjbMIlOauxjfbqeFfk_XHztn5Otq9PL-uHbWIE00OCKSAvUyilEgK4kqbOQYAUmts607mqwNQytXmGIgWeYQagMrH_ADeIYkWSQ68JPsZg66IPTYdhKhgU-42KfxvN_s3B78eys9WvfRxl5rdHjtFgWwd0pol_pYqrjGvxA5RabpQ</recordid><startdate>19981101</startdate><enddate>19981101</enddate><creator>BRANISTEANU, R</creator><creator>AIKING, H</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19981101</creationdate><title>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</title><author>BRANISTEANU, R ; AIKING, H</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c317t-a50a2b50b46330264cf90304372ef8796d0cf45e98a35028a80068345e902caa3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Air Pollutants - analysis</topic><topic>Air Pollutants, Occupational - analysis</topic><topic>Applied sciences</topic><topic>Atmospheric pollution</topic><topic>Chromatography, High Pressure Liquid</topic><topic>Cities</topic><topic>Coal</topic><topic>Dust</topic><topic>Exact sciences and technology</topic><topic>Humans</topic><topic>Indoor pollution and occupational exposure</topic><topic>Occupational Exposure - analysis</topic><topic>Particle Size</topic><topic>Pollution</topic><topic>Polycyclic Aromatic Hydrocarbons - analysis</topic><topic>Power Plants</topic><topic>Romania</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>BRANISTEANU, R</creatorcontrib><creatorcontrib>AIKING, H</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>International archives of occupational and environmental health</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>BRANISTEANU, R</au><au>AIKING, H</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air</atitle><jtitle>International archives of occupational and environmental health</jtitle><addtitle>Int Arch Occup Environ Health</addtitle><date>1998-11-01</date><risdate>1998</risdate><volume>71</volume><issue>8</issue><spage>533</spage><epage>536</epage><pages>533-536</pages><issn>0340-0131</issn><eissn>1432-1246</eissn><coden>IAEHDW</coden><abstract>To evaluate the balance between occupational and environmental exposure to suspended particulate matter (SPM) and polycyclic aromatic hydrocarbons (PAHs), comparison measurements were performed in a coal-fired power plant and the urban atmosphere from the town nearby.
The analysis of SPM for PAH content was done according to a high-performance liquid chromatography (HPLC)-based method. The microscopic assessment was performed using scanning electron microscopy (SEM) by silver coverage of the samples derived by air filter.
Contrary to expectations, the results showed low levels of particle-bound PAHs in the occupational environment (< 1 ng benzo(a)pyrene/m3 air) and high levels in urban air (range 80-1250 ng benzo(a)pyrene/m3). The SPM collected from the power plant exhibited non-respirable characteristics (particles larger than 10 microm), whereas urban SPM almost exclusively contained respirable airborne particles (<3 microm).
The PAH burden, combined with the enhanced probability of respiratory absorption, confers a much greater hazard potential to the urban SPM. Under these conditions, in areas or countries in which old technologies remain in use, occupational exposure to SPM containing PAHs might represent a severe underestimation of the total risk as it does not take into account the background air pollution.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>9860161</pmid><doi>10.1007/s004200050319</doi><tpages>4</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0340-0131 |
ispartof | International archives of occupational and environmental health, 1998-11, Vol.71 (8), p.533-536 |
issn | 0340-0131 1432-1246 |
language | eng |
recordid | cdi_crossref_primary_10_1007_s004200050319 |
source | MEDLINE; SpringerLink Journals |
subjects | Air Pollutants - analysis Air Pollutants, Occupational - analysis Applied sciences Atmospheric pollution Chromatography, High Pressure Liquid Cities Coal Dust Exact sciences and technology Humans Indoor pollution and occupational exposure Occupational Exposure - analysis Particle Size Pollution Polycyclic Aromatic Hydrocarbons - analysis Power Plants Romania |
title | Exposure to polycyclic aromatic hydrocarbons in occupational versus urban environmental air |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-09T14%3A51%3A49IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Exposure%20to%20polycyclic%20aromatic%20hydrocarbons%20in%20occupational%20versus%20urban%20environmental%20air&rft.jtitle=International%20archives%20of%20occupational%20and%20environmental%20health&rft.au=BRANISTEANU,%20R&rft.date=1998-11-01&rft.volume=71&rft.issue=8&rft.spage=533&rft.epage=536&rft.pages=533-536&rft.issn=0340-0131&rft.eissn=1432-1246&rft.coden=IAEHDW&rft_id=info:doi/10.1007/s004200050319&rft_dat=%3Cpubmed_cross%3E9860161%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/9860161&rfr_iscdi=true |