Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol

A PVC-based membrane containing metoprolol molecularly imprinted polymer (MIP) coated directly on graphite electrode for the determination of metoprolol in real samples is reported. This potentiometric sensor was designed by dispersing the MIP particles in dioctylphthalate plasticizer as solvent med...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of the Iranian Chemical Society 2010-09, Vol.7 (3), p.759-769
Hauptverfasser: Saber Tehrani, M., Vardini, M. T., Abroomand Azar, P., Husain, S. W.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 769
container_issue 3
container_start_page 759
container_title Journal of the Iranian Chemical Society
container_volume 7
creator Saber Tehrani, M.
Vardini, M. T.
Abroomand Azar, P.
Husain, S. W.
description A PVC-based membrane containing metoprolol molecularly imprinted polymer (MIP) coated directly on graphite electrode for the determination of metoprolol in real samples is reported. This potentiometric sensor was designed by dispersing the MIP particles in dioctylphthalate plasticizer as solvent mediator and then embedded in polyvinyl chloride matrix. The electrode exhibited a near-Nernstian slope of 55.4 ± 1 mV decade -1 for metoprolol over a wide concentration range between 2.0 × 10 -7 -8.0 × 10 -3 M and a detection limit of 1.3 × 10 -7 M. With a response time of about 14 s it could be used for at least 6 months without any divergence in potential. The proposed electrode can be used in the pH range of 3.5-10.5 and can reveal good selectivities for metoprolol over a wide variety of ions. Finally, the designed sensor was successfully applied as an indicator electrode to determine the concentration of metoprolol in tablets, human urine and plasma. The results were compared favorably with those obtained by HPLC method and showed satisfactory agreements with them.
doi_str_mv 10.1007/BF03246066
format Article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF03246066</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1007_BF03246066</sourcerecordid><originalsourceid>FETCH-LOGICAL-c303t-ed65b817c724660fa03774f84ab0cdd71a2126970dd78c5ee32a25057ae0d50f3</originalsourceid><addsrcrecordid>eNptkE1PwzAMhiMEEuPjwi_IGVRw0qYpR1YxQNoEB0Dcqqxxtk5pUyXZYf-eTANx4WRbemz5eQm5YnDLAOTddAY5L0ooyyMyYTIXGS94dfzbg_w6JWchbACEBFFMyLBwFtutVd7uaNePvhsiajo6u-vR06kKaXr7rLMF9kuvBsxqp_bEyqtx3UWkmPajdxqpcZ7GNVKNEX3fDSp2bqDO0B6jG72zzl6QE6NswMufek4-Zo_v9XM2f316qR_mWZtDHjPUpVhWTLYyyZRgFORSFqYq1BJarSVTnPHyXkLqq1Yg5lxxkZwUghZg8nNyfbjbeheCR9Mks175XcOg2SfV_CWV4JsDHPb6K_TNxm39kP77j_4G2nVqiw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol</title><source>Springer Nature - Complete Springer Journals</source><source>Alma/SFX Local Collection</source><creator>Saber Tehrani, M. ; Vardini, M. T. ; Abroomand Azar, P. ; Husain, S. W.</creator><creatorcontrib>Saber Tehrani, M. ; Vardini, M. T. ; Abroomand Azar, P. ; Husain, S. W.</creatorcontrib><description>A PVC-based membrane containing metoprolol molecularly imprinted polymer (MIP) coated directly on graphite electrode for the determination of metoprolol in real samples is reported. This potentiometric sensor was designed by dispersing the MIP particles in dioctylphthalate plasticizer as solvent mediator and then embedded in polyvinyl chloride matrix. The electrode exhibited a near-Nernstian slope of 55.4 ± 1 mV decade -1 for metoprolol over a wide concentration range between 2.0 × 10 -7 -8.0 × 10 -3 M and a detection limit of 1.3 × 10 -7 M. With a response time of about 14 s it could be used for at least 6 months without any divergence in potential. The proposed electrode can be used in the pH range of 3.5-10.5 and can reveal good selectivities for metoprolol over a wide variety of ions. Finally, the designed sensor was successfully applied as an indicator electrode to determine the concentration of metoprolol in tablets, human urine and plasma. The results were compared favorably with those obtained by HPLC method and showed satisfactory agreements with them.</description><identifier>ISSN: 1735-207X</identifier><identifier>EISSN: 1735-2428</identifier><identifier>DOI: 10.1007/BF03246066</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Analytical Chemistry ; Biochemistry ; Chemistry ; Chemistry and Materials Science ; Inorganic Chemistry ; Organic Chemistry ; Physical Chemistry</subject><ispartof>Journal of the Iranian Chemical Society, 2010-09, Vol.7 (3), p.759-769</ispartof><rights>Iranian Chemical Society 2010</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c303t-ed65b817c724660fa03774f84ab0cdd71a2126970dd78c5ee32a25057ae0d50f3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://link.springer.com/content/pdf/10.1007/BF03246066$$EPDF$$P50$$Gspringer$$H</linktopdf><linktohtml>$$Uhttps://link.springer.com/10.1007/BF03246066$$EHTML$$P50$$Gspringer$$H</linktohtml><link.rule.ids>314,776,780,27901,27902,41464,42533,51294</link.rule.ids></links><search><creatorcontrib>Saber Tehrani, M.</creatorcontrib><creatorcontrib>Vardini, M. T.</creatorcontrib><creatorcontrib>Abroomand Azar, P.</creatorcontrib><creatorcontrib>Husain, S. W.</creatorcontrib><title>Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol</title><title>Journal of the Iranian Chemical Society</title><addtitle>JICS</addtitle><description>A PVC-based membrane containing metoprolol molecularly imprinted polymer (MIP) coated directly on graphite electrode for the determination of metoprolol in real samples is reported. This potentiometric sensor was designed by dispersing the MIP particles in dioctylphthalate plasticizer as solvent mediator and then embedded in polyvinyl chloride matrix. The electrode exhibited a near-Nernstian slope of 55.4 ± 1 mV decade -1 for metoprolol over a wide concentration range between 2.0 × 10 -7 -8.0 × 10 -3 M and a detection limit of 1.3 × 10 -7 M. With a response time of about 14 s it could be used for at least 6 months without any divergence in potential. The proposed electrode can be used in the pH range of 3.5-10.5 and can reveal good selectivities for metoprolol over a wide variety of ions. Finally, the designed sensor was successfully applied as an indicator electrode to determine the concentration of metoprolol in tablets, human urine and plasma. The results were compared favorably with those obtained by HPLC method and showed satisfactory agreements with them.</description><subject>Analytical Chemistry</subject><subject>Biochemistry</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Inorganic Chemistry</subject><subject>Organic Chemistry</subject><subject>Physical Chemistry</subject><issn>1735-207X</issn><issn>1735-2428</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNptkE1PwzAMhiMEEuPjwi_IGVRw0qYpR1YxQNoEB0Dcqqxxtk5pUyXZYf-eTANx4WRbemz5eQm5YnDLAOTddAY5L0ooyyMyYTIXGS94dfzbg_w6JWchbACEBFFMyLBwFtutVd7uaNePvhsiajo6u-vR06kKaXr7rLMF9kuvBsxqp_bEyqtx3UWkmPajdxqpcZ7GNVKNEX3fDSp2bqDO0B6jG72zzl6QE6NswMufek4-Zo_v9XM2f316qR_mWZtDHjPUpVhWTLYyyZRgFORSFqYq1BJarSVTnPHyXkLqq1Yg5lxxkZwUghZg8nNyfbjbeheCR9Mks175XcOg2SfV_CWV4JsDHPb6K_TNxm39kP77j_4G2nVqiw</recordid><startdate>20100901</startdate><enddate>20100901</enddate><creator>Saber Tehrani, M.</creator><creator>Vardini, M. T.</creator><creator>Abroomand Azar, P.</creator><creator>Husain, S. W.</creator><general>Springer-Verlag</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20100901</creationdate><title>Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol</title><author>Saber Tehrani, M. ; Vardini, M. T. ; Abroomand Azar, P. ; Husain, S. W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c303t-ed65b817c724660fa03774f84ab0cdd71a2126970dd78c5ee32a25057ae0d50f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Analytical Chemistry</topic><topic>Biochemistry</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Inorganic Chemistry</topic><topic>Organic Chemistry</topic><topic>Physical Chemistry</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saber Tehrani, M.</creatorcontrib><creatorcontrib>Vardini, M. T.</creatorcontrib><creatorcontrib>Abroomand Azar, P.</creatorcontrib><creatorcontrib>Husain, S. W.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of the Iranian Chemical Society</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saber Tehrani, M.</au><au>Vardini, M. T.</au><au>Abroomand Azar, P.</au><au>Husain, S. W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol</atitle><jtitle>Journal of the Iranian Chemical Society</jtitle><stitle>JICS</stitle><date>2010-09-01</date><risdate>2010</risdate><volume>7</volume><issue>3</issue><spage>759</spage><epage>769</epage><pages>759-769</pages><issn>1735-207X</issn><eissn>1735-2428</eissn><abstract>A PVC-based membrane containing metoprolol molecularly imprinted polymer (MIP) coated directly on graphite electrode for the determination of metoprolol in real samples is reported. This potentiometric sensor was designed by dispersing the MIP particles in dioctylphthalate plasticizer as solvent mediator and then embedded in polyvinyl chloride matrix. The electrode exhibited a near-Nernstian slope of 55.4 ± 1 mV decade -1 for metoprolol over a wide concentration range between 2.0 × 10 -7 -8.0 × 10 -3 M and a detection limit of 1.3 × 10 -7 M. With a response time of about 14 s it could be used for at least 6 months without any divergence in potential. The proposed electrode can be used in the pH range of 3.5-10.5 and can reveal good selectivities for metoprolol over a wide variety of ions. Finally, the designed sensor was successfully applied as an indicator electrode to determine the concentration of metoprolol in tablets, human urine and plasma. The results were compared favorably with those obtained by HPLC method and showed satisfactory agreements with them.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><doi>10.1007/BF03246066</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1735-207X
ispartof Journal of the Iranian Chemical Society, 2010-09, Vol.7 (3), p.759-769
issn 1735-207X
1735-2428
language eng
recordid cdi_crossref_primary_10_1007_BF03246066
source Springer Nature - Complete Springer Journals; Alma/SFX Local Collection
subjects Analytical Chemistry
Biochemistry
Chemistry
Chemistry and Materials Science
Inorganic Chemistry
Organic Chemistry
Physical Chemistry
title Molecularly imprinted polymer Based PVC-Membrane-Coated graphite electrode for the determination of metoprolol
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-02T11%3A18%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Molecularly%20imprinted%20polymer%20Based%20PVC-Membrane-Coated%20graphite%20electrode%20for%20the%20determination%20of%20metoprolol&rft.jtitle=Journal%20of%20the%20Iranian%20Chemical%20Society&rft.au=Saber%20Tehrani,%20M.&rft.date=2010-09-01&rft.volume=7&rft.issue=3&rft.spage=759&rft.epage=769&rft.pages=759-769&rft.issn=1735-207X&rft.eissn=1735-2428&rft_id=info:doi/10.1007/BF03246066&rft_dat=%3Ccrossref_sprin%3E10_1007_BF03246066%3C/crossref_sprin%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true