A telemetry system for recording body temperature of large numbers of caged rodents

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical & Biological Engineering 1972-09, Vol.10 (5), p.677-684
1. Verfasser: Barr, R E
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 684
container_issue 5
container_start_page 677
container_title Medical & Biological Engineering
container_volume 10
creator Barr, R E
description
doi_str_mv 10.1007/BF02476086
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF02476086</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81592800</sourcerecordid><originalsourceid>FETCH-LOGICAL-c241t-47ff3882b94c03adae923650037e1e0e827819f3c3677b23842be50b9f46c64f3</originalsourceid><addsrcrecordid>eNpFkM9LwzAUx4Moc04v3oWcPAjVlx9N0uMcToWBBxW8lTR9GZN2mUl76H9vx4ae3pfHh8_hQ8g1g3sGoB8el8ClVmDUCZkyLVkGUspTMgXgeaYK9XVOLlL6BsiVFHJCJjnocYkpeZ_TDhtssYsDTUPqsKU-RBrRhVhvtmtahXoYmXaH0XZ9RBo8bWxcI932bYUx7R_OrrGmMdS47dIlOfO2SXh1vDPyuXz6WLxkq7fn18V8lTkuWZdJ7b0whleFdCBsbbHgQuUAQiNDQMO1YYUXTiitKy6M5BXmUBVeKqekFzNye_DuYvjpMXVlu0kOm8ZuMfSpNCwvuBl9M3J3AF0MKUX05S5uWhuHkkG5L1j-Fxzhm6O1r1qs_9BjMvEL83ZqlA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81592800</pqid></control><display><type>article</type><title>A telemetry system for recording body temperature of large numbers of caged rodents</title><source>MEDLINE</source><source>SpringerLink Journals</source><creator>Barr, R E</creator><creatorcontrib>Barr, R E</creatorcontrib><identifier>ISSN: 0025-696X</identifier><identifier>EISSN: 1741-0444</identifier><identifier>DOI: 10.1007/BF02476086</identifier><identifier>PMID: 5076433</identifier><language>eng</language><publisher>England</publisher><subject>Animals ; Body Temperature ; Electronics ; Hibernation ; Sciuridae - physiology ; Telemetry - instrumentation</subject><ispartof>Medical &amp; Biological Engineering, 1972-09, Vol.10 (5), p.677-684</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c241t-47ff3882b94c03adae923650037e1e0e827819f3c3677b23842be50b9f46c64f3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/5076433$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Barr, R E</creatorcontrib><title>A telemetry system for recording body temperature of large numbers of caged rodents</title><title>Medical &amp; Biological Engineering</title><addtitle>Med Biol Eng</addtitle><subject>Animals</subject><subject>Body Temperature</subject><subject>Electronics</subject><subject>Hibernation</subject><subject>Sciuridae - physiology</subject><subject>Telemetry - instrumentation</subject><issn>0025-696X</issn><issn>1741-0444</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1972</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkM9LwzAUx4Moc04v3oWcPAjVlx9N0uMcToWBBxW8lTR9GZN2mUl76H9vx4ae3pfHh8_hQ8g1g3sGoB8el8ClVmDUCZkyLVkGUspTMgXgeaYK9XVOLlL6BsiVFHJCJjnocYkpeZ_TDhtssYsDTUPqsKU-RBrRhVhvtmtahXoYmXaH0XZ9RBo8bWxcI932bYUx7R_OrrGmMdS47dIlOfO2SXh1vDPyuXz6WLxkq7fn18V8lTkuWZdJ7b0whleFdCBsbbHgQuUAQiNDQMO1YYUXTiitKy6M5BXmUBVeKqekFzNye_DuYvjpMXVlu0kOm8ZuMfSpNCwvuBl9M3J3AF0MKUX05S5uWhuHkkG5L1j-Fxzhm6O1r1qs_9BjMvEL83ZqlA</recordid><startdate>197209</startdate><enddate>197209</enddate><creator>Barr, R E</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>197209</creationdate><title>A telemetry system for recording body temperature of large numbers of caged rodents</title><author>Barr, R E</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c241t-47ff3882b94c03adae923650037e1e0e827819f3c3677b23842be50b9f46c64f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1972</creationdate><topic>Animals</topic><topic>Body Temperature</topic><topic>Electronics</topic><topic>Hibernation</topic><topic>Sciuridae - physiology</topic><topic>Telemetry - instrumentation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Barr, R E</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>Medical &amp; Biological Engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Barr, R E</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A telemetry system for recording body temperature of large numbers of caged rodents</atitle><jtitle>Medical &amp; Biological Engineering</jtitle><addtitle>Med Biol Eng</addtitle><date>1972-09</date><risdate>1972</risdate><volume>10</volume><issue>5</issue><spage>677</spage><epage>684</epage><pages>677-684</pages><issn>0025-696X</issn><eissn>1741-0444</eissn><cop>England</cop><pmid>5076433</pmid><doi>10.1007/BF02476086</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0025-696X
ispartof Medical & Biological Engineering, 1972-09, Vol.10 (5), p.677-684
issn 0025-696X
1741-0444
language eng
recordid cdi_crossref_primary_10_1007_BF02476086
source MEDLINE; SpringerLink Journals
subjects Animals
Body Temperature
Electronics
Hibernation
Sciuridae - physiology
Telemetry - instrumentation
title A telemetry system for recording body temperature of large numbers of caged rodents
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T07%3A50%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20telemetry%20system%20for%20recording%20body%20temperature%20of%20large%20numbers%20of%20caged%20rodents&rft.jtitle=Medical%20&%20Biological%20Engineering&rft.au=Barr,%20R%20E&rft.date=1972-09&rft.volume=10&rft.issue=5&rft.spage=677&rft.epage=684&rft.pages=677-684&rft.issn=0025-696X&rft.eissn=1741-0444&rft_id=info:doi/10.1007/BF02476086&rft_dat=%3Cproquest_cross%3E81592800%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81592800&rft_id=info:pmid/5076433&rfr_iscdi=true