Measuring the background acoustic noise from a BN-600 steam generator
Background noise in the steam generator of a sodium cooled reactor represents interference in leak detection and must be measured as a necessary stage in designing an acoustic system for detecting the leakage of water into sodium. This paper presents measurements made on the BN-600 steam generators...
Gespeichert in:
Veröffentlicht in: | Sov. At. Energy (Engl. Transl.); (United States) 1987-04, Vol.62 (4), p.332-333 |
---|---|
Hauptverfasser: | , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | Background noise in the steam generator of a sodium cooled reactor represents interference in leak detection and must be measured as a necessary stage in designing an acoustic system for detecting the leakage of water into sodium. This paper presents measurements made on the BN-600 steam generators with two sensors in the lower sodium channels of the evaporator and superheater. The noise was measured over a range of 0.63 to 160 kHz by a spectrum analyzer. Noise spectra are graphed. |
---|---|
ISSN: | 0038-531X 1573-8205 |
DOI: | 10.1007/BF01123377 |