Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material

Osteotomies of the distal femur in 19 rabbits were operatively fixed with totally biodegradable implants. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showing healing of the osteotomy within 6 weeks. The fixation proved stable sufficiently during healing of the...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Archives of Orthopaedic and Traumatic Surgery 1986-01, Vol.106 (1), p.1-4
Hauptverfasser: Vainionpää, S, Vihtonen, K, Mero, M, Pätiälä, H, Rokkanen, P, Kilpikari, J, Törmälä, P
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 4
container_issue 1
container_start_page 1
container_title Archives of Orthopaedic and Traumatic Surgery
container_volume 106
creator Vainionpää, S
Vihtonen, K
Mero, M
Pätiälä, H
Rokkanen, P
Kilpikari, J
Törmälä, P
description Osteotomies of the distal femur in 19 rabbits were operatively fixed with totally biodegradable implants. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showing healing of the osteotomy within 6 weeks. The fixation proved stable sufficiently during healing of the osteotomized bone. The osteotomies united without delay and malalignment did not occur, although no external support was used and the rabbits were allowed to walk freely after the operation. Successful use of the biodegradable fixation developed in the present study was reported recently for the treatment of fractures of the ankle.
doi_str_mv 10.1007/BF00435641
format Article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00435641</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3032127</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-51233416f5511aabea5ceb88fc24e862efcb30c03d496ffbb973e7b1809fd2893</originalsourceid><addsrcrecordid>eNpFkMFLwzAUh4Moc8xdvAs5C9UkL23Tow6rwsCLnkvSvrhIu4wkw_nf27Kh7_Lg_T5-8D5Crjm744yV9481YxLyQvIzMucSZAYVL87JnIGUmZJSXpJljF9sHFBlLqoZmQEDwUU5J03tDjo5v6XeUjzsMLgBt0n31MeEPvnBYZyytEHauTglFod9mG5BG-NSpN8ubahxvsPPoDtteqSDTmOV7q_IhdV9xOVpL8hH_fS-esnWb8-vq4d11gLnKcu5AJC8sHnOudYGdd6iUcq2QqIqBNrWAGsZdLIqrDWmKgFLwxWrbCdUBQtye-xtg48xoG124yc6_DScNZOn5t_TCN8c4d3eDNj9oScr8AtAlWOG</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Vainionpää, S ; Vihtonen, K ; Mero, M ; Pätiälä, H ; Rokkanen, P ; Kilpikari, J ; Törmälä, P</creator><creatorcontrib>Vainionpää, S ; Vihtonen, K ; Mero, M ; Pätiälä, H ; Rokkanen, P ; Kilpikari, J ; Törmälä, P</creatorcontrib><description>Osteotomies of the distal femur in 19 rabbits were operatively fixed with totally biodegradable implants. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showing healing of the osteotomy within 6 weeks. The fixation proved stable sufficiently during healing of the osteotomized bone. The osteotomies united without delay and malalignment did not occur, although no external support was used and the rabbits were allowed to walk freely after the operation. Successful use of the biodegradable fixation developed in the present study was reported recently for the treatment of fractures of the ankle.</description><identifier>ISSN: 0344-8444</identifier><identifier>EISSN: 1434-3916</identifier><identifier>DOI: 10.1007/BF00435641</identifier><identifier>PMID: 3032127</identifier><language>eng</language><publisher>Germany</publisher><subject>Animals ; Biocompatible Materials ; Femur - diagnostic imaging ; Femur - pathology ; Femur - surgery ; Osteotomy - methods ; Polyglycolic Acid - therapeutic use ; Prostheses and Implants ; Rabbits ; Radiography ; Sutures ; Wound Healing</subject><ispartof>Archives of Orthopaedic and Traumatic Surgery, 1986-01, Vol.106 (1), p.1-4</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-51233416f5511aabea5ceb88fc24e862efcb30c03d496ffbb973e7b1809fd2893</citedby><cites>FETCH-LOGICAL-c311t-51233416f5511aabea5ceb88fc24e862efcb30c03d496ffbb973e7b1809fd2893</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3032127$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Vainionpää, S</creatorcontrib><creatorcontrib>Vihtonen, K</creatorcontrib><creatorcontrib>Mero, M</creatorcontrib><creatorcontrib>Pätiälä, H</creatorcontrib><creatorcontrib>Rokkanen, P</creatorcontrib><creatorcontrib>Kilpikari, J</creatorcontrib><creatorcontrib>Törmälä, P</creatorcontrib><title>Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material</title><title>Archives of Orthopaedic and Traumatic Surgery</title><addtitle>Arch Orthop Trauma Surg</addtitle><description>Osteotomies of the distal femur in 19 rabbits were operatively fixed with totally biodegradable implants. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showing healing of the osteotomy within 6 weeks. The fixation proved stable sufficiently during healing of the osteotomized bone. The osteotomies united without delay and malalignment did not occur, although no external support was used and the rabbits were allowed to walk freely after the operation. Successful use of the biodegradable fixation developed in the present study was reported recently for the treatment of fractures of the ankle.</description><subject>Animals</subject><subject>Biocompatible Materials</subject><subject>Femur - diagnostic imaging</subject><subject>Femur - pathology</subject><subject>Femur - surgery</subject><subject>Osteotomy - methods</subject><subject>Polyglycolic Acid - therapeutic use</subject><subject>Prostheses and Implants</subject><subject>Rabbits</subject><subject>Radiography</subject><subject>Sutures</subject><subject>Wound Healing</subject><issn>0344-8444</issn><issn>1434-3916</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1986</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkMFLwzAUh4Moc8xdvAs5C9UkL23Tow6rwsCLnkvSvrhIu4wkw_nf27Kh7_Lg_T5-8D5Crjm744yV9481YxLyQvIzMucSZAYVL87JnIGUmZJSXpJljF9sHFBlLqoZmQEDwUU5J03tDjo5v6XeUjzsMLgBt0n31MeEPvnBYZyytEHauTglFod9mG5BG-NSpN8ubahxvsPPoDtteqSDTmOV7q_IhdV9xOVpL8hH_fS-esnWb8-vq4d11gLnKcu5AJC8sHnOudYGdd6iUcq2QqIqBNrWAGsZdLIqrDWmKgFLwxWrbCdUBQtye-xtg48xoG124yc6_DScNZOn5t_TCN8c4d3eDNj9oScr8AtAlWOG</recordid><startdate>19860101</startdate><enddate>19860101</enddate><creator>Vainionpää, S</creator><creator>Vihtonen, K</creator><creator>Mero, M</creator><creator>Pätiälä, H</creator><creator>Rokkanen, P</creator><creator>Kilpikari, J</creator><creator>Törmälä, P</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19860101</creationdate><title>Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material</title><author>Vainionpää, S ; Vihtonen, K ; Mero, M ; Pätiälä, H ; Rokkanen, P ; Kilpikari, J ; Törmälä, P</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-51233416f5511aabea5ceb88fc24e862efcb30c03d496ffbb973e7b1809fd2893</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1986</creationdate><topic>Animals</topic><topic>Biocompatible Materials</topic><topic>Femur - diagnostic imaging</topic><topic>Femur - pathology</topic><topic>Femur - surgery</topic><topic>Osteotomy - methods</topic><topic>Polyglycolic Acid - therapeutic use</topic><topic>Prostheses and Implants</topic><topic>Rabbits</topic><topic>Radiography</topic><topic>Sutures</topic><topic>Wound Healing</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vainionpää, S</creatorcontrib><creatorcontrib>Vihtonen, K</creatorcontrib><creatorcontrib>Mero, M</creatorcontrib><creatorcontrib>Pätiälä, H</creatorcontrib><creatorcontrib>Rokkanen, P</creatorcontrib><creatorcontrib>Kilpikari, J</creatorcontrib><creatorcontrib>Törmälä, P</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>Archives of Orthopaedic and Traumatic Surgery</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vainionpää, S</au><au>Vihtonen, K</au><au>Mero, M</au><au>Pätiälä, H</au><au>Rokkanen, P</au><au>Kilpikari, J</au><au>Törmälä, P</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material</atitle><jtitle>Archives of Orthopaedic and Traumatic Surgery</jtitle><addtitle>Arch Orthop Trauma Surg</addtitle><date>1986-01-01</date><risdate>1986</risdate><volume>106</volume><issue>1</issue><spage>1</spage><epage>4</epage><pages>1-4</pages><issn>0344-8444</issn><eissn>1434-3916</eissn><abstract>Osteotomies of the distal femur in 19 rabbits were operatively fixed with totally biodegradable implants. Radiographic, histological, microradiographic, and oxytetracycline-labeling studies showing healing of the osteotomy within 6 weeks. The fixation proved stable sufficiently during healing of the osteotomized bone. The osteotomies united without delay and malalignment did not occur, although no external support was used and the rabbits were allowed to walk freely after the operation. Successful use of the biodegradable fixation developed in the present study was reported recently for the treatment of fractures of the ankle.</abstract><cop>Germany</cop><pmid>3032127</pmid><doi>10.1007/BF00435641</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0344-8444
ispartof Archives of Orthopaedic and Traumatic Surgery, 1986-01, Vol.106 (1), p.1-4
issn 0344-8444
1434-3916
language eng
recordid cdi_crossref_primary_10_1007_BF00435641
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Animals
Biocompatible Materials
Femur - diagnostic imaging
Femur - pathology
Femur - surgery
Osteotomy - methods
Polyglycolic Acid - therapeutic use
Prostheses and Implants
Rabbits
Radiography
Sutures
Wound Healing
title Fixation of experimental osteotomies of the distal femur of rabbits with biodegradable material
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-25T04%3A17%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Fixation%20of%20experimental%20osteotomies%20of%20the%20distal%20femur%20of%20rabbits%20with%20biodegradable%20material&rft.jtitle=Archives%20of%20Orthopaedic%20and%20Traumatic%20Surgery&rft.au=Vainionp%C3%A4%C3%A4,%20S&rft.date=1986-01-01&rft.volume=106&rft.issue=1&rft.spage=1&rft.epage=4&rft.pages=1-4&rft.issn=0344-8444&rft.eissn=1434-3916&rft_id=info:doi/10.1007/BF00435641&rft_dat=%3Cpubmed_cross%3E3032127%3C/pubmed_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/3032127&rfr_iscdi=true