In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals

The in vivo 99mTc-RBC labelling efficiency and stability of labelling was assessed after pretinning with a high-stannous content DTPA kit (Sn DTPA) in comparison with Sn-pyrophosphate (Sn PPi) and a low-stannous DTPA kit (DTPA). The distribution in Sprague Dawley rats showed that similar fractions o...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European Journal of Nuclear Medicine 1984, Vol.9 (7), p.295-299
Hauptverfasser: POPESCU, H. I, LESSEM, J, ERJAVEC, M, FÜGER, G. F
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 299
container_issue 7
container_start_page 295
container_title European Journal of Nuclear Medicine
container_volume 9
creator POPESCU, H. I
LESSEM, J
ERJAVEC, M
FÜGER, G. F
description The in vivo 99mTc-RBC labelling efficiency and stability of labelling was assessed after pretinning with a high-stannous content DTPA kit (Sn DTPA) in comparison with Sn-pyrophosphate (Sn PPi) and a low-stannous DTPA kit (DTPA). The distribution in Sprague Dawley rats showed that similar fractions of administered 99mTc remained within the blood pool after pretinning with Sn DTPA and Sn PPi when equal quantities of stannous ions (15 micrograms/kg) and equal time intervals (30 min) between successive IV injections of pretinning agent and 99mTc-pertechnetate were used. Significantly lower fractions were found when DTPA (1.9 micrograms Sn2+/kg) was used for pretinning. The rate of 99mTc elution emphasises the importance of the Sn2+ concentration used, not only for labelling efficiency but also for stability of the labelling. Satisfactory intravascular activity, exceeding 80% during the first hour post-injection, was demonstrated in three volunteers after 99mTc injection, when Sn DTPA was used for pretinning. Left ventricular ejection fractions (LVEF) measured by equilibrium radionuclide angiography after pretinning with Sn DTPA in 24 patients correlated well (r = 0.98) with those obtained by contrast angiographies over a broad spectrum of values (0.14-0.72). Four repeated LVEF measurements at 45-min intervals in six additional patients at rest showed excellent reproducibility in each patient: maximum variation was less than 6%.
doi_str_mv 10.1007/BF00276457
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00276457</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>81205968</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1588-4c0be2ccb178c3b38b54604899a3353e61802742c83fcf1287acbeebb88204e03</originalsourceid><addsrcrecordid>eNpFkE1LAzEQhoMotX5cvAs5iAdhdbLJbpKjFr9AEKSelyRN2sjupia7iv_eFEu9zBzm4WWeF6EzAtcEgN_cPQCUvGYV30NTUhNZcBByH02BMihqKfkhOkrpAwAYo9UETWoQoqRiilbPPf7yXwG3Stu29f0SB4ff7mb42w8rLGU3N9iFiHUbwgKvQ2ix79RyA45pMxfeORttP-A0qL4PY8JRLXxYr1TslLHj4I1q0wk6cHnZ0-0-Ru8P9_PZU_Hy-vg8u30pDKmEKJgBbUtjNOHCUE2FrlgNTEipKK2orYnIqqw0gjrjSCm4MtparbMPMAv0GF3-5a5j-BxtGprOJ5PVVG_zb40gJVSyFhm8-gNNDClF65p1zGbxpyHQbGpt_mvN8Pk2ddSdXezQbY_5frG9q5RtXVS98WmHyZpxXkn6CxddfqI</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>81205968</pqid></control><display><type>article</type><title>In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals</title><source>MEDLINE</source><source>Springer Nature - Complete Springer Journals</source><creator>POPESCU, H. I ; LESSEM, J ; ERJAVEC, M ; FÜGER, G. F</creator><creatorcontrib>POPESCU, H. I ; LESSEM, J ; ERJAVEC, M ; FÜGER, G. F</creatorcontrib><description>The in vivo 99mTc-RBC labelling efficiency and stability of labelling was assessed after pretinning with a high-stannous content DTPA kit (Sn DTPA) in comparison with Sn-pyrophosphate (Sn PPi) and a low-stannous DTPA kit (DTPA). The distribution in Sprague Dawley rats showed that similar fractions of administered 99mTc remained within the blood pool after pretinning with Sn DTPA and Sn PPi when equal quantities of stannous ions (15 micrograms/kg) and equal time intervals (30 min) between successive IV injections of pretinning agent and 99mTc-pertechnetate were used. Significantly lower fractions were found when DTPA (1.9 micrograms Sn2+/kg) was used for pretinning. The rate of 99mTc elution emphasises the importance of the Sn2+ concentration used, not only for labelling efficiency but also for stability of the labelling. Satisfactory intravascular activity, exceeding 80% during the first hour post-injection, was demonstrated in three volunteers after 99mTc injection, when Sn DTPA was used for pretinning. Left ventricular ejection fractions (LVEF) measured by equilibrium radionuclide angiography after pretinning with Sn DTPA in 24 patients correlated well (r = 0.98) with those obtained by contrast angiographies over a broad spectrum of values (0.14-0.72). Four repeated LVEF measurements at 45-min intervals in six additional patients at rest showed excellent reproducibility in each patient: maximum variation was less than 6%.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00276457</identifier><identifier>PMID: 6088238</identifier><identifier>CODEN: EJNMD9</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Animals ; Biological and medical sciences ; Cardiovascular system ; Erythrocytes ; Female ; Heart - diagnostic imaging ; Heart Function Tests - methods ; Humans ; Injections, Intravenous ; Investigative techniques, diagnostic techniques (general aspects) ; Medical sciences ; Pentetic Acid ; Polyphosphates ; Radionuclide Imaging ; Radionuclide investigations ; Rats ; Rats, Inbred Strains ; Sodium Pertechnetate Tc 99m ; Stroke Volume ; Technetium ; Tin Polyphosphates</subject><ispartof>European Journal of Nuclear Medicine, 1984, Vol.9 (7), p.295-299</ispartof><rights>1984 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1588-4c0be2ccb178c3b38b54604899a3353e61802742c83fcf1287acbeebb88204e03</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,777,781,4010,27904,27905,27906</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=9647759$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6088238$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>POPESCU, H. I</creatorcontrib><creatorcontrib>LESSEM, J</creatorcontrib><creatorcontrib>ERJAVEC, M</creatorcontrib><creatorcontrib>FÜGER, G. F</creatorcontrib><title>In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>The in vivo 99mTc-RBC labelling efficiency and stability of labelling was assessed after pretinning with a high-stannous content DTPA kit (Sn DTPA) in comparison with Sn-pyrophosphate (Sn PPi) and a low-stannous DTPA kit (DTPA). The distribution in Sprague Dawley rats showed that similar fractions of administered 99mTc remained within the blood pool after pretinning with Sn DTPA and Sn PPi when equal quantities of stannous ions (15 micrograms/kg) and equal time intervals (30 min) between successive IV injections of pretinning agent and 99mTc-pertechnetate were used. Significantly lower fractions were found when DTPA (1.9 micrograms Sn2+/kg) was used for pretinning. The rate of 99mTc elution emphasises the importance of the Sn2+ concentration used, not only for labelling efficiency but also for stability of the labelling. Satisfactory intravascular activity, exceeding 80% during the first hour post-injection, was demonstrated in three volunteers after 99mTc injection, when Sn DTPA was used for pretinning. Left ventricular ejection fractions (LVEF) measured by equilibrium radionuclide angiography after pretinning with Sn DTPA in 24 patients correlated well (r = 0.98) with those obtained by contrast angiographies over a broad spectrum of values (0.14-0.72). Four repeated LVEF measurements at 45-min intervals in six additional patients at rest showed excellent reproducibility in each patient: maximum variation was less than 6%.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Cardiovascular system</subject><subject>Erythrocytes</subject><subject>Female</subject><subject>Heart - diagnostic imaging</subject><subject>Heart Function Tests - methods</subject><subject>Humans</subject><subject>Injections, Intravenous</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Medical sciences</subject><subject>Pentetic Acid</subject><subject>Polyphosphates</subject><subject>Radionuclide Imaging</subject><subject>Radionuclide investigations</subject><subject>Rats</subject><subject>Rats, Inbred Strains</subject><subject>Sodium Pertechnetate Tc 99m</subject><subject>Stroke Volume</subject><subject>Technetium</subject><subject>Tin Polyphosphates</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkE1LAzEQhoMotX5cvAs5iAdhdbLJbpKjFr9AEKSelyRN2sjupia7iv_eFEu9zBzm4WWeF6EzAtcEgN_cPQCUvGYV30NTUhNZcBByH02BMihqKfkhOkrpAwAYo9UETWoQoqRiilbPPf7yXwG3Stu29f0SB4ff7mb42w8rLGU3N9iFiHUbwgKvQ2ix79RyA45pMxfeORttP-A0qL4PY8JRLXxYr1TslLHj4I1q0wk6cHnZ0-0-Ru8P9_PZU_Hy-vg8u30pDKmEKJgBbUtjNOHCUE2FrlgNTEipKK2orYnIqqw0gjrjSCm4MtparbMPMAv0GF3-5a5j-BxtGprOJ5PVVG_zb40gJVSyFhm8-gNNDClF65p1zGbxpyHQbGpt_mvN8Pk2ddSdXezQbY_5frG9q5RtXVS98WmHyZpxXkn6CxddfqI</recordid><startdate>1984</startdate><enddate>1984</enddate><creator>POPESCU, H. I</creator><creator>LESSEM, J</creator><creator>ERJAVEC, M</creator><creator>FÜGER, G. F</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1984</creationdate><title>In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals</title><author>POPESCU, H. I ; LESSEM, J ; ERJAVEC, M ; FÜGER, G. F</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1588-4c0be2ccb178c3b38b54604899a3353e61802742c83fcf1287acbeebb88204e03</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1984</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Cardiovascular system</topic><topic>Erythrocytes</topic><topic>Female</topic><topic>Heart - diagnostic imaging</topic><topic>Heart Function Tests - methods</topic><topic>Humans</topic><topic>Injections, Intravenous</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Medical sciences</topic><topic>Pentetic Acid</topic><topic>Polyphosphates</topic><topic>Radionuclide Imaging</topic><topic>Radionuclide investigations</topic><topic>Rats</topic><topic>Rats, Inbred Strains</topic><topic>Sodium Pertechnetate Tc 99m</topic><topic>Stroke Volume</topic><topic>Technetium</topic><topic>Tin Polyphosphates</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>POPESCU, H. I</creatorcontrib><creatorcontrib>LESSEM, J</creatorcontrib><creatorcontrib>ERJAVEC, M</creatorcontrib><creatorcontrib>FÜGER, G. F</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>POPESCU, H. I</au><au>LESSEM, J</au><au>ERJAVEC, M</au><au>FÜGER, G. F</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1984</date><risdate>1984</risdate><volume>9</volume><issue>7</issue><spage>295</spage><epage>299</epage><pages>295-299</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><coden>EJNMD9</coden><abstract>The in vivo 99mTc-RBC labelling efficiency and stability of labelling was assessed after pretinning with a high-stannous content DTPA kit (Sn DTPA) in comparison with Sn-pyrophosphate (Sn PPi) and a low-stannous DTPA kit (DTPA). The distribution in Sprague Dawley rats showed that similar fractions of administered 99mTc remained within the blood pool after pretinning with Sn DTPA and Sn PPi when equal quantities of stannous ions (15 micrograms/kg) and equal time intervals (30 min) between successive IV injections of pretinning agent and 99mTc-pertechnetate were used. Significantly lower fractions were found when DTPA (1.9 micrograms Sn2+/kg) was used for pretinning. The rate of 99mTc elution emphasises the importance of the Sn2+ concentration used, not only for labelling efficiency but also for stability of the labelling. Satisfactory intravascular activity, exceeding 80% during the first hour post-injection, was demonstrated in three volunteers after 99mTc injection, when Sn DTPA was used for pretinning. Left ventricular ejection fractions (LVEF) measured by equilibrium radionuclide angiography after pretinning with Sn DTPA in 24 patients correlated well (r = 0.98) with those obtained by contrast angiographies over a broad spectrum of values (0.14-0.72). Four repeated LVEF measurements at 45-min intervals in six additional patients at rest showed excellent reproducibility in each patient: maximum variation was less than 6%.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>6088238</pmid><doi>10.1007/BF00276457</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal of Nuclear Medicine, 1984, Vol.9 (7), p.295-299
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00276457
source MEDLINE; Springer Nature - Complete Springer Journals
subjects Animals
Biological and medical sciences
Cardiovascular system
Erythrocytes
Female
Heart - diagnostic imaging
Heart Function Tests - methods
Humans
Injections, Intravenous
Investigative techniques, diagnostic techniques (general aspects)
Medical sciences
Pentetic Acid
Polyphosphates
Radionuclide Imaging
Radionuclide investigations
Rats
Rats, Inbred Strains
Sodium Pertechnetate Tc 99m
Stroke Volume
Technetium
Tin Polyphosphates
title In vivo labelling of RBC with 99mTc for blood pool imaging using different stannous radiopharmaceuticals
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T20%3A45%3A33IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=In%20vivo%20labelling%20of%20RBC%20with%2099mTc%20for%20blood%20pool%20imaging%20using%20different%20stannous%20radiopharmaceuticals&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=POPESCU,%20H.%20I&rft.date=1984&rft.volume=9&rft.issue=7&rft.spage=295&rft.epage=299&rft.pages=295-299&rft.issn=0340-6997&rft.eissn=1619-7089&rft.coden=EJNMD9&rft_id=info:doi/10.1007/BF00276457&rft_dat=%3Cproquest_cross%3E81205968%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=81205968&rft_id=info:pmid/6088238&rfr_iscdi=true