False positive bone scan in bone tumors of the lower limb

When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading res...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:European Journal of Nuclear Medicine 1977-09, Vol.2 (3), p.179-181
Hauptverfasser: Casara, D, de Besi, P, Fiorentino, M, Fornasiero, A, Melanotte, P, Palu, G, Sperandio, P, Vinante, O
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 181
container_issue 3
container_start_page 179
container_title European Journal of Nuclear Medicine
container_volume 2
creator Casara, D
de Besi, P
Fiorentino, M
Fornasiero, A
Melanotte, P
Palu, G
Sperandio, P
Vinante, O
description When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.
doi_str_mv 10.1007/BF00257277
format Article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00257277</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73704874</sourcerecordid><originalsourceid>FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</originalsourceid><addsrcrecordid>eNpFkDFPwzAQhS1EBaGwsLJ4YkAKnGO7Z49QEUCqxAJzFLu2CEriYicg_j0prWB4Oj3puzd8hJwzuGYAeHNXAhQSC8QDkrEF0zmC0ockAy4gX2iNx-QkpXcAEILLIzJDpnWREV3WbXJ0E1IzNJ-OmtA7mmzd06bflWHsQkw0eDq8OdqGLxdp23TmlMz89vdsf-fktbx_WT7mq-eHp-XtKreFgiFnykuvpUWBHKQByYycYrzVnoMRSjHjjffMFdIyWQsHsgbvUHG1Rmv5nFzudjcxfIwuDVXXJOvatu5dGFOFHEEoFBN4tQNtDClF56tNbLo6flcMqq2l6t_SBF_sV0fTufUf-quF_wAWOGBe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73704874</pqid></control><display><type>article</type><title>False positive bone scan in bone tumors of the lower limb</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</creator><creatorcontrib>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</creatorcontrib><description>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00257277</identifier><identifier>PMID: 71992</identifier><language>eng</language><publisher>Germany</publisher><subject>Adolescent ; Adult ; Bleomycin ; Bone Neoplasms - diagnostic imaging ; Child ; Cobalt Radioisotopes ; False Positive Reactions ; Female ; Gallium Radioisotopes ; Humans ; Leg - diagnostic imaging ; Lymphoma, Large B-Cell, Diffuse - diagnostic imaging ; Male ; Osteosarcoma - diagnostic imaging ; Phosphates ; Radionuclide Imaging ; Sarcoma - diagnostic imaging ; Sarcoma, Ewing - diagnostic imaging ; Technetium</subject><ispartof>European Journal of Nuclear Medicine, 1977-09, Vol.2 (3), p.179-181</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/71992$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Casara, D</creatorcontrib><creatorcontrib>de Besi, P</creatorcontrib><creatorcontrib>Fiorentino, M</creatorcontrib><creatorcontrib>Fornasiero, A</creatorcontrib><creatorcontrib>Melanotte, P</creatorcontrib><creatorcontrib>Palu, G</creatorcontrib><creatorcontrib>Sperandio, P</creatorcontrib><creatorcontrib>Vinante, O</creatorcontrib><title>False positive bone scan in bone tumors of the lower limb</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Bleomycin</subject><subject>Bone Neoplasms - diagnostic imaging</subject><subject>Child</subject><subject>Cobalt Radioisotopes</subject><subject>False Positive Reactions</subject><subject>Female</subject><subject>Gallium Radioisotopes</subject><subject>Humans</subject><subject>Leg - diagnostic imaging</subject><subject>Lymphoma, Large B-Cell, Diffuse - diagnostic imaging</subject><subject>Male</subject><subject>Osteosarcoma - diagnostic imaging</subject><subject>Phosphates</subject><subject>Radionuclide Imaging</subject><subject>Sarcoma - diagnostic imaging</subject><subject>Sarcoma, Ewing - diagnostic imaging</subject><subject>Technetium</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1977</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkDFPwzAQhS1EBaGwsLJ4YkAKnGO7Z49QEUCqxAJzFLu2CEriYicg_j0prWB4Oj3puzd8hJwzuGYAeHNXAhQSC8QDkrEF0zmC0ockAy4gX2iNx-QkpXcAEILLIzJDpnWREV3WbXJ0E1IzNJ-OmtA7mmzd06bflWHsQkw0eDq8OdqGLxdp23TmlMz89vdsf-fktbx_WT7mq-eHp-XtKreFgiFnykuvpUWBHKQByYycYrzVnoMRSjHjjffMFdIyWQsHsgbvUHG1Rmv5nFzudjcxfIwuDVXXJOvatu5dGFOFHEEoFBN4tQNtDClF56tNbLo6flcMqq2l6t_SBF_sV0fTufUf-quF_wAWOGBe</recordid><startdate>19770930</startdate><enddate>19770930</enddate><creator>Casara, D</creator><creator>de Besi, P</creator><creator>Fiorentino, M</creator><creator>Fornasiero, A</creator><creator>Melanotte, P</creator><creator>Palu, G</creator><creator>Sperandio, P</creator><creator>Vinante, O</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19770930</creationdate><title>False positive bone scan in bone tumors of the lower limb</title><author>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1977</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Bleomycin</topic><topic>Bone Neoplasms - diagnostic imaging</topic><topic>Child</topic><topic>Cobalt Radioisotopes</topic><topic>False Positive Reactions</topic><topic>Female</topic><topic>Gallium Radioisotopes</topic><topic>Humans</topic><topic>Leg - diagnostic imaging</topic><topic>Lymphoma, Large B-Cell, Diffuse - diagnostic imaging</topic><topic>Male</topic><topic>Osteosarcoma - diagnostic imaging</topic><topic>Phosphates</topic><topic>Radionuclide Imaging</topic><topic>Sarcoma - diagnostic imaging</topic><topic>Sarcoma, Ewing - diagnostic imaging</topic><topic>Technetium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Casara, D</creatorcontrib><creatorcontrib>de Besi, P</creatorcontrib><creatorcontrib>Fiorentino, M</creatorcontrib><creatorcontrib>Fornasiero, A</creatorcontrib><creatorcontrib>Melanotte, P</creatorcontrib><creatorcontrib>Palu, G</creatorcontrib><creatorcontrib>Sperandio, P</creatorcontrib><creatorcontrib>Vinante, O</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Casara, D</au><au>de Besi, P</au><au>Fiorentino, M</au><au>Fornasiero, A</au><au>Melanotte, P</au><au>Palu, G</au><au>Sperandio, P</au><au>Vinante, O</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>False positive bone scan in bone tumors of the lower limb</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1977-09-30</date><risdate>1977</risdate><volume>2</volume><issue>3</issue><spage>179</spage><epage>181</epage><pages>179-181</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><abstract>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</abstract><cop>Germany</cop><pmid>71992</pmid><doi>10.1007/BF00257277</doi><tpages>3</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal of Nuclear Medicine, 1977-09, Vol.2 (3), p.179-181
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00257277
source MEDLINE; SpringerLink Journals - AutoHoldings
subjects Adolescent
Adult
Bleomycin
Bone Neoplasms - diagnostic imaging
Child
Cobalt Radioisotopes
False Positive Reactions
Female
Gallium Radioisotopes
Humans
Leg - diagnostic imaging
Lymphoma, Large B-Cell, Diffuse - diagnostic imaging
Male
Osteosarcoma - diagnostic imaging
Phosphates
Radionuclide Imaging
Sarcoma - diagnostic imaging
Sarcoma, Ewing - diagnostic imaging
Technetium
title False positive bone scan in bone tumors of the lower limb
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T04%3A23%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=False%20positive%20bone%20scan%20in%20bone%20tumors%20of%20the%20lower%20limb&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=Casara,%20D&rft.date=1977-09-30&rft.volume=2&rft.issue=3&rft.spage=179&rft.epage=181&rft.pages=179-181&rft.issn=0340-6997&rft.eissn=1619-7089&rft_id=info:doi/10.1007/BF00257277&rft_dat=%3Cproquest_cross%3E73704874%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73704874&rft_id=info:pmid/71992&rfr_iscdi=true