False positive bone scan in bone tumors of the lower limb
When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading res...
Gespeichert in:
Veröffentlicht in: | European Journal of Nuclear Medicine 1977-09, Vol.2 (3), p.179-181 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 181 |
---|---|
container_issue | 3 |
container_start_page | 179 |
container_title | European Journal of Nuclear Medicine |
container_volume | 2 |
creator | Casara, D de Besi, P Fiorentino, M Fornasiero, A Melanotte, P Palu, G Sperandio, P Vinante, O |
description | When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used. |
doi_str_mv | 10.1007/BF00257277 |
format | Article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00257277</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>73704874</sourcerecordid><originalsourceid>FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</originalsourceid><addsrcrecordid>eNpFkDFPwzAQhS1EBaGwsLJ4YkAKnGO7Z49QEUCqxAJzFLu2CEriYicg_j0prWB4Oj3puzd8hJwzuGYAeHNXAhQSC8QDkrEF0zmC0ockAy4gX2iNx-QkpXcAEILLIzJDpnWREV3WbXJ0E1IzNJ-OmtA7mmzd06bflWHsQkw0eDq8OdqGLxdp23TmlMz89vdsf-fktbx_WT7mq-eHp-XtKreFgiFnykuvpUWBHKQByYycYrzVnoMRSjHjjffMFdIyWQsHsgbvUHG1Rmv5nFzudjcxfIwuDVXXJOvatu5dGFOFHEEoFBN4tQNtDClF56tNbLo6flcMqq2l6t_SBF_sV0fTufUf-quF_wAWOGBe</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>73704874</pqid></control><display><type>article</type><title>False positive bone scan in bone tumors of the lower limb</title><source>MEDLINE</source><source>SpringerLink Journals - AutoHoldings</source><creator>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</creator><creatorcontrib>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</creatorcontrib><description>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00257277</identifier><identifier>PMID: 71992</identifier><language>eng</language><publisher>Germany</publisher><subject>Adolescent ; Adult ; Bleomycin ; Bone Neoplasms - diagnostic imaging ; Child ; Cobalt Radioisotopes ; False Positive Reactions ; Female ; Gallium Radioisotopes ; Humans ; Leg - diagnostic imaging ; Lymphoma, Large B-Cell, Diffuse - diagnostic imaging ; Male ; Osteosarcoma - diagnostic imaging ; Phosphates ; Radionuclide Imaging ; Sarcoma - diagnostic imaging ; Sarcoma, Ewing - diagnostic imaging ; Technetium</subject><ispartof>European Journal of Nuclear Medicine, 1977-09, Vol.2 (3), p.179-181</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/71992$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Casara, D</creatorcontrib><creatorcontrib>de Besi, P</creatorcontrib><creatorcontrib>Fiorentino, M</creatorcontrib><creatorcontrib>Fornasiero, A</creatorcontrib><creatorcontrib>Melanotte, P</creatorcontrib><creatorcontrib>Palu, G</creatorcontrib><creatorcontrib>Sperandio, P</creatorcontrib><creatorcontrib>Vinante, O</creatorcontrib><title>False positive bone scan in bone tumors of the lower limb</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</description><subject>Adolescent</subject><subject>Adult</subject><subject>Bleomycin</subject><subject>Bone Neoplasms - diagnostic imaging</subject><subject>Child</subject><subject>Cobalt Radioisotopes</subject><subject>False Positive Reactions</subject><subject>Female</subject><subject>Gallium Radioisotopes</subject><subject>Humans</subject><subject>Leg - diagnostic imaging</subject><subject>Lymphoma, Large B-Cell, Diffuse - diagnostic imaging</subject><subject>Male</subject><subject>Osteosarcoma - diagnostic imaging</subject><subject>Phosphates</subject><subject>Radionuclide Imaging</subject><subject>Sarcoma - diagnostic imaging</subject><subject>Sarcoma, Ewing - diagnostic imaging</subject><subject>Technetium</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1977</creationdate><recordtype>article</recordtype><sourceid>EIF</sourceid><recordid>eNpFkDFPwzAQhS1EBaGwsLJ4YkAKnGO7Z49QEUCqxAJzFLu2CEriYicg_j0prWB4Oj3puzd8hJwzuGYAeHNXAhQSC8QDkrEF0zmC0ockAy4gX2iNx-QkpXcAEILLIzJDpnWREV3WbXJ0E1IzNJ-OmtA7mmzd06bflWHsQkw0eDq8OdqGLxdp23TmlMz89vdsf-fktbx_WT7mq-eHp-XtKreFgiFnykuvpUWBHKQByYycYrzVnoMRSjHjjffMFdIyWQsHsgbvUHG1Rmv5nFzudjcxfIwuDVXXJOvatu5dGFOFHEEoFBN4tQNtDClF56tNbLo6flcMqq2l6t_SBF_sV0fTufUf-quF_wAWOGBe</recordid><startdate>19770930</startdate><enddate>19770930</enddate><creator>Casara, D</creator><creator>de Besi, P</creator><creator>Fiorentino, M</creator><creator>Fornasiero, A</creator><creator>Melanotte, P</creator><creator>Palu, G</creator><creator>Sperandio, P</creator><creator>Vinante, O</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>19770930</creationdate><title>False positive bone scan in bone tumors of the lower limb</title><author>Casara, D ; de Besi, P ; Fiorentino, M ; Fornasiero, A ; Melanotte, P ; Palu, G ; Sperandio, P ; Vinante, O</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c280t-18f5f95c747305b051b551bbfc9f30b4881bfbff1e25c15a4e05a0fe7838d7cc3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1977</creationdate><topic>Adolescent</topic><topic>Adult</topic><topic>Bleomycin</topic><topic>Bone Neoplasms - diagnostic imaging</topic><topic>Child</topic><topic>Cobalt Radioisotopes</topic><topic>False Positive Reactions</topic><topic>Female</topic><topic>Gallium Radioisotopes</topic><topic>Humans</topic><topic>Leg - diagnostic imaging</topic><topic>Lymphoma, Large B-Cell, Diffuse - diagnostic imaging</topic><topic>Male</topic><topic>Osteosarcoma - diagnostic imaging</topic><topic>Phosphates</topic><topic>Radionuclide Imaging</topic><topic>Sarcoma - diagnostic imaging</topic><topic>Sarcoma, Ewing - diagnostic imaging</topic><topic>Technetium</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Casara, D</creatorcontrib><creatorcontrib>de Besi, P</creatorcontrib><creatorcontrib>Fiorentino, M</creatorcontrib><creatorcontrib>Fornasiero, A</creatorcontrib><creatorcontrib>Melanotte, P</creatorcontrib><creatorcontrib>Palu, G</creatorcontrib><creatorcontrib>Sperandio, P</creatorcontrib><creatorcontrib>Vinante, O</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Casara, D</au><au>de Besi, P</au><au>Fiorentino, M</au><au>Fornasiero, A</au><au>Melanotte, P</au><au>Palu, G</au><au>Sperandio, P</au><au>Vinante, O</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>False positive bone scan in bone tumors of the lower limb</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1977-09-30</date><risdate>1977</risdate><volume>2</volume><issue>3</issue><spage>179</spage><epage>181</epage><pages>179-181</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><abstract>When examined using bone scanning agents, eight out of nine patients with lower limb malignancy, and neither of two affected in the upper limb showed a pathologic focus of isotope uptake in an area distal to the tumor. On pathologic examination the positive findings proved false. Such misleading results were found to be avoidable if a tumor-seeking agent instead of a bone scanning one is used.</abstract><cop>Germany</cop><pmid>71992</pmid><doi>10.1007/BF00257277</doi><tpages>3</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0340-6997 |
ispartof | European Journal of Nuclear Medicine, 1977-09, Vol.2 (3), p.179-181 |
issn | 0340-6997 1619-7089 |
language | eng |
recordid | cdi_crossref_primary_10_1007_BF00257277 |
source | MEDLINE; SpringerLink Journals - AutoHoldings |
subjects | Adolescent Adult Bleomycin Bone Neoplasms - diagnostic imaging Child Cobalt Radioisotopes False Positive Reactions Female Gallium Radioisotopes Humans Leg - diagnostic imaging Lymphoma, Large B-Cell, Diffuse - diagnostic imaging Male Osteosarcoma - diagnostic imaging Phosphates Radionuclide Imaging Sarcoma - diagnostic imaging Sarcoma, Ewing - diagnostic imaging Technetium |
title | False positive bone scan in bone tumors of the lower limb |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-11T04%3A23%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=False%20positive%20bone%20scan%20in%20bone%20tumors%20of%20the%20lower%20limb&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=Casara,%20D&rft.date=1977-09-30&rft.volume=2&rft.issue=3&rft.spage=179&rft.epage=181&rft.pages=179-181&rft.issn=0340-6997&rft.eissn=1619-7089&rft_id=info:doi/10.1007/BF00257277&rft_dat=%3Cproquest_cross%3E73704874%3C/proquest_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=73704874&rft_id=info:pmid/71992&rfr_iscdi=true |