Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes
The synthesis of the UiO‐66/rGO material involved combining UiO‐66 with reduced graphene oxide (rGO). This resulting composite found application in the electrochemical determination of salbutamol (SAL) through modification of a glassy‐carbon electrode (GCE) with UiO‐66/rGO. Differential pulse voltam...
Gespeichert in:
Veröffentlicht in: | Vietnam journal of chemistry 2024-02, Vol.62 (1), p.103-113 |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 113 |
---|---|
container_issue | 1 |
container_start_page | 103 |
container_title | Vietnam journal of chemistry |
container_volume | 62 |
creator | Thanh Nhi, Le Thi Hoa, Le Thi Uyen, Dam To Sinh, Le Hoang Nguyen, Do Mai Bach, Ta Ngoc Tam Toan, Tran Thanh Quang Khieu, Dinh |
description | The synthesis of the UiO‐66/rGO material involved combining UiO‐66 with reduced graphene oxide (rGO). This resulting composite found application in the electrochemical determination of salbutamol (SAL) through modification of a glassy‐carbon electrode (GCE) with UiO‐66/rGO. Differential pulse voltammetry served as the chosen technique, offering a wide linear range spanning 1–160 µm and demonstrating a low limit of detection at 0.84 µm. To ensure the reliability of the electrode, various aspects such as sensitivity, repeatability, reproducibility, and stability were meticulously studied. When applied to the analysis of SAL in swine urine solutions (n = 3), the electrode exhibited good recovery rates. Remarkably, the results obtained through this method correlated well with those acquired using ultra‐high performance liquid chromatography (UPLC).
–UiO‐66/rGO was used as an electrode modifier to develop a novel methof for determining salbutamol in swinve urine solution.
–The reliability of the proposed sensor, various aspects such as selectivity, repeatability, reproducibility and stability were addressed.
–The proposed method correlated well with those accquired using the ultra‐high performance chromatography. |
doi_str_mv | 10.1002/vjch.202300189 |
format | Article |
fullrecord | <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_vjch_202300189</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>VJCH202300189</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2849-12fc72445afa6ab0a1325b0928b4653ba20b650b146456ff4b5a8e010f98ae983</originalsourceid><addsrcrecordid>eNqFkLFOwzAURS0EElXpyuwfSPvs2K4zoqq0oEpdKGtkO7biKqnBTqi68Ql8I18CURGMTO8N59zhIHRLYEoA6Oxtb-opBZoDEFlcoBHlc5pJKuUlGoEUIpsTxq7RJKU9DIzIcyAjVC8ba7oYTG1bb1SDK9vZ2PqD6nw44OBwUo3uO9WGBvsDVq-9DX3CKTT9QCR89F2Nd377-f4hxCyuhqcNlXfeVtie1yubbtCVU02yk587Rrv75dNinW22q4fF3SYzVLIiI9SZOWWMK6eE0qBITrmGgkrNBM-1oqAFB02YYFw4xzRX0gIBV0hlC5mP0fS8a2JIKVpXvkTfqngqCZRDqnJIVf6m-haKs3D0jT39Q5fPj4v1n_sFMQlwyg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes</title><source>Wiley Online Library Journals Frontfile Complete</source><source>Alma/SFX Local Collection</source><creator>Thanh Nhi, Le Thi ; Hoa, Le Thi ; Uyen, Dam To ; Sinh, Le Hoang ; Nguyen, Do Mai ; Bach, Ta Ngoc ; Tam Toan, Tran Thanh ; Quang Khieu, Dinh</creator><creatorcontrib>Thanh Nhi, Le Thi ; Hoa, Le Thi ; Uyen, Dam To ; Sinh, Le Hoang ; Nguyen, Do Mai ; Bach, Ta Ngoc ; Tam Toan, Tran Thanh ; Quang Khieu, Dinh</creatorcontrib><description>The synthesis of the UiO‐66/rGO material involved combining UiO‐66 with reduced graphene oxide (rGO). This resulting composite found application in the electrochemical determination of salbutamol (SAL) through modification of a glassy‐carbon electrode (GCE) with UiO‐66/rGO. Differential pulse voltammetry served as the chosen technique, offering a wide linear range spanning 1–160 µm and demonstrating a low limit of detection at 0.84 µm. To ensure the reliability of the electrode, various aspects such as sensitivity, repeatability, reproducibility, and stability were meticulously studied. When applied to the analysis of SAL in swine urine solutions (n = 3), the electrode exhibited good recovery rates. Remarkably, the results obtained through this method correlated well with those acquired using ultra‐high performance liquid chromatography (UPLC).
–UiO‐66/rGO was used as an electrode modifier to develop a novel methof for determining salbutamol in swinve urine solution.
–The reliability of the proposed sensor, various aspects such as selectivity, repeatability, reproducibility and stability were addressed.
–The proposed method correlated well with those accquired using the ultra‐high performance chromatography.</description><identifier>ISSN: 0866-7144</identifier><identifier>ISSN: 2572-8288</identifier><identifier>EISSN: 2572-8288</identifier><identifier>DOI: 10.1002/vjch.202300189</identifier><language>eng</language><subject>electrochemical determination ; reduced graphene oxide ; salbutamol ; swine urine ; UiO‐66</subject><ispartof>Vietnam journal of chemistry, 2024-02, Vol.62 (1), p.103-113</ispartof><rights>2024 Vietnam Academy of Science and Technology and Wiley‐VCH GmbH.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2849-12fc72445afa6ab0a1325b0928b4653ba20b650b146456ff4b5a8e010f98ae983</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fvjch.202300189$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fvjch.202300189$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,778,782,1414,27911,27912,45561,45562</link.rule.ids></links><search><creatorcontrib>Thanh Nhi, Le Thi</creatorcontrib><creatorcontrib>Hoa, Le Thi</creatorcontrib><creatorcontrib>Uyen, Dam To</creatorcontrib><creatorcontrib>Sinh, Le Hoang</creatorcontrib><creatorcontrib>Nguyen, Do Mai</creatorcontrib><creatorcontrib>Bach, Ta Ngoc</creatorcontrib><creatorcontrib>Tam Toan, Tran Thanh</creatorcontrib><creatorcontrib>Quang Khieu, Dinh</creatorcontrib><title>Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes</title><title>Vietnam journal of chemistry</title><description>The synthesis of the UiO‐66/rGO material involved combining UiO‐66 with reduced graphene oxide (rGO). This resulting composite found application in the electrochemical determination of salbutamol (SAL) through modification of a glassy‐carbon electrode (GCE) with UiO‐66/rGO. Differential pulse voltammetry served as the chosen technique, offering a wide linear range spanning 1–160 µm and demonstrating a low limit of detection at 0.84 µm. To ensure the reliability of the electrode, various aspects such as sensitivity, repeatability, reproducibility, and stability were meticulously studied. When applied to the analysis of SAL in swine urine solutions (n = 3), the electrode exhibited good recovery rates. Remarkably, the results obtained through this method correlated well with those acquired using ultra‐high performance liquid chromatography (UPLC).
–UiO‐66/rGO was used as an electrode modifier to develop a novel methof for determining salbutamol in swinve urine solution.
–The reliability of the proposed sensor, various aspects such as selectivity, repeatability, reproducibility and stability were addressed.
–The proposed method correlated well with those accquired using the ultra‐high performance chromatography.</description><subject>electrochemical determination</subject><subject>reduced graphene oxide</subject><subject>salbutamol</subject><subject>swine urine</subject><subject>UiO‐66</subject><issn>0866-7144</issn><issn>2572-8288</issn><issn>2572-8288</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkLFOwzAURS0EElXpyuwfSPvs2K4zoqq0oEpdKGtkO7biKqnBTqi68Ql8I18CURGMTO8N59zhIHRLYEoA6Oxtb-opBZoDEFlcoBHlc5pJKuUlGoEUIpsTxq7RJKU9DIzIcyAjVC8ba7oYTG1bb1SDK9vZ2PqD6nw44OBwUo3uO9WGBvsDVq-9DX3CKTT9QCR89F2Nd377-f4hxCyuhqcNlXfeVtie1yubbtCVU02yk587Rrv75dNinW22q4fF3SYzVLIiI9SZOWWMK6eE0qBITrmGgkrNBM-1oqAFB02YYFw4xzRX0gIBV0hlC5mP0fS8a2JIKVpXvkTfqngqCZRDqnJIVf6m-haKs3D0jT39Q5fPj4v1n_sFMQlwyg</recordid><startdate>202402</startdate><enddate>202402</enddate><creator>Thanh Nhi, Le Thi</creator><creator>Hoa, Le Thi</creator><creator>Uyen, Dam To</creator><creator>Sinh, Le Hoang</creator><creator>Nguyen, Do Mai</creator><creator>Bach, Ta Ngoc</creator><creator>Tam Toan, Tran Thanh</creator><creator>Quang Khieu, Dinh</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202402</creationdate><title>Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes</title><author>Thanh Nhi, Le Thi ; Hoa, Le Thi ; Uyen, Dam To ; Sinh, Le Hoang ; Nguyen, Do Mai ; Bach, Ta Ngoc ; Tam Toan, Tran Thanh ; Quang Khieu, Dinh</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2849-12fc72445afa6ab0a1325b0928b4653ba20b650b146456ff4b5a8e010f98ae983</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>electrochemical determination</topic><topic>reduced graphene oxide</topic><topic>salbutamol</topic><topic>swine urine</topic><topic>UiO‐66</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Thanh Nhi, Le Thi</creatorcontrib><creatorcontrib>Hoa, Le Thi</creatorcontrib><creatorcontrib>Uyen, Dam To</creatorcontrib><creatorcontrib>Sinh, Le Hoang</creatorcontrib><creatorcontrib>Nguyen, Do Mai</creatorcontrib><creatorcontrib>Bach, Ta Ngoc</creatorcontrib><creatorcontrib>Tam Toan, Tran Thanh</creatorcontrib><creatorcontrib>Quang Khieu, Dinh</creatorcontrib><collection>CrossRef</collection><jtitle>Vietnam journal of chemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Thanh Nhi, Le Thi</au><au>Hoa, Le Thi</au><au>Uyen, Dam To</au><au>Sinh, Le Hoang</au><au>Nguyen, Do Mai</au><au>Bach, Ta Ngoc</au><au>Tam Toan, Tran Thanh</au><au>Quang Khieu, Dinh</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes</atitle><jtitle>Vietnam journal of chemistry</jtitle><date>2024-02</date><risdate>2024</risdate><volume>62</volume><issue>1</issue><spage>103</spage><epage>113</epage><pages>103-113</pages><issn>0866-7144</issn><issn>2572-8288</issn><eissn>2572-8288</eissn><abstract>The synthesis of the UiO‐66/rGO material involved combining UiO‐66 with reduced graphene oxide (rGO). This resulting composite found application in the electrochemical determination of salbutamol (SAL) through modification of a glassy‐carbon electrode (GCE) with UiO‐66/rGO. Differential pulse voltammetry served as the chosen technique, offering a wide linear range spanning 1–160 µm and demonstrating a low limit of detection at 0.84 µm. To ensure the reliability of the electrode, various aspects such as sensitivity, repeatability, reproducibility, and stability were meticulously studied. When applied to the analysis of SAL in swine urine solutions (n = 3), the electrode exhibited good recovery rates. Remarkably, the results obtained through this method correlated well with those acquired using ultra‐high performance liquid chromatography (UPLC).
–UiO‐66/rGO was used as an electrode modifier to develop a novel methof for determining salbutamol in swinve urine solution.
–The reliability of the proposed sensor, various aspects such as selectivity, repeatability, reproducibility and stability were addressed.
–The proposed method correlated well with those accquired using the ultra‐high performance chromatography.</abstract><doi>10.1002/vjch.202300189</doi><tpages>11</tpages><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0866-7144 |
ispartof | Vietnam journal of chemistry, 2024-02, Vol.62 (1), p.103-113 |
issn | 0866-7144 2572-8288 2572-8288 |
language | eng |
recordid | cdi_crossref_primary_10_1002_vjch_202300189 |
source | Wiley Online Library Journals Frontfile Complete; Alma/SFX Local Collection |
subjects | electrochemical determination reduced graphene oxide salbutamol swine urine UiO‐66 |
title | Electrochemical determination of salbutamol in aqueous solutions with UiO‐66/rGO‐modified electrodes |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-15T20%3A16%3A26IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Electrochemical%20determination%20of%20salbutamol%20in%20aqueous%20solutions%20with%20UiO%E2%80%9066/rGO%E2%80%90modified%20electrodes&rft.jtitle=Vietnam%20journal%20of%20chemistry&rft.au=Thanh%20Nhi,%20Le%20Thi&rft.date=2024-02&rft.volume=62&rft.issue=1&rft.spage=103&rft.epage=113&rft.pages=103-113&rft.issn=0866-7144&rft.eissn=2572-8288&rft_id=info:doi/10.1002/vjch.202300189&rft_dat=%3Cwiley_cross%3EVJCH202300189%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |