Modulating ultrasound contrast generation from injectable nanodroplets for proton range verification by varying the degree of superheat

Purpose Despite the physical benefits of protons over conventional photon radiation in cancer treatment, range uncertainties impede the ability to harness the full potential of proton therapy. While monitoring the proton range in vivo could reduce the currently adopted safety margins, a routinely ap...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical physics (Lancaster) 2021-04, Vol.48 (4), p.1983-1995
Hauptverfasser: Heymans, Sophie V., Carlier, Bram, Toumia, Yosra, Nooijens, Sjoerd, Ingram, Marcus, Giammanco, Andrea, d’Agostino, Emiliano, Crijns, Wouter, Bertrand, Alexander, Paradossi, Gaio, Himmelreich, Uwe, D’hooge, Jan, Sterpin, Edmond, Van Den Abeele, Koen
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
Beschreibung
Zusammenfassung:Purpose Despite the physical benefits of protons over conventional photon radiation in cancer treatment, range uncertainties impede the ability to harness the full potential of proton therapy. While monitoring the proton range in vivo could reduce the currently adopted safety margins, a routinely applicable range verification technique is still lacking. Recently, phase‐change nanodroplets were proposed for proton range verification, demonstrating a reproducible relationship between the proton range and generated ultrasound contrast after radiation‐induced vaporization at 25°C. In this study, previous findings are extended with proton irradiations at different temperatures, including the physiological temperature of 37°C, for a novel nanodroplet formulation. Moreover, the potential to modulate the linear energy transfer (LET) threshold for vaporization by varying the degree of superheat is investigated, where the aim is to demonstrate vaporization of nanodroplets directly by primary protons. Methods Perfluorobutane nanodroplets with a shell made of polyvinyl alcohol (PVA‐PFB) or 10,12‐pentacosadyinoic acid (PCDA‐PFB) were dispersed in polyacrylamide hydrogels and irradiated with 62 MeV passively scattered protons at temperatures of 37°C and 50°C. Nanodroplet transition into echogenic microbubbles was assessed using ultrasound imaging (gray value and attenuation analysis) and optical images. The proton range was measured independently and compared to the generated contrast. Results Nanodroplet design proved crucial to ensure thermal stability, as PVA‐shelled nanodroplets dramatically outperformed their PCDA‐shelled counterpart. At body temperature, a uniform radiation response proximal to the Bragg peak is attributed to nuclear reaction products interacting with PVA‐PFB nanodroplets, with the 50% drop in ultrasound contrast being 0.17 mm ± 0.20 mm (mean ± standard deviation) in front of the proton range. Also at 50°C, highly reproducible ultrasound contrast profiles were obtained with shifts of −0.74 mm ± 0.09 mm (gray value analysis), −0.86 mm ± 0.04 mm (attenuation analysis) and −0.64 mm ± 0.29 mm (optical analysis). Moreover, a strong contrast enhancement was observed near the Bragg peak, suggesting that nanodroplets were sensitive to primary protons. Conclusions By varying the degree of superheat of the nanodroplets’ core, one can modulate the intensity of the generated ultrasound contrast. Moreover, a submillimeter reproducible relationship between the
ISSN:0094-2405
2473-4209
DOI:10.1002/mp.14778