Performance analysis of a series transformer for complex impedance matching

The ability to match any two complex impedances with a transforming series transmission line of appropriate length is known, but has not been widely studied or deployed. The usefulness of this approach is demonstrated by comparing the performance with that of the series line followed by a quarter‐wa...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Microwave and optical technology letters 2005-06, Vol.45 (6), p.491-494
Hauptverfasser: Hall, Leonard T., Hansen, Hedley J., Davis, Bruce R., Abbott, Derek
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 494
container_issue 6
container_start_page 491
container_title Microwave and optical technology letters
container_volume 45
creator Hall, Leonard T.
Hansen, Hedley J.
Davis, Bruce R.
Abbott, Derek
description The ability to match any two complex impedances with a transforming series transmission line of appropriate length is known, but has not been widely studied or deployed. The usefulness of this approach is demonstrated by comparing the performance with that of the series line followed by a quarter‐wavelength transformer, single‐stub tuner, and double‐stub tuner. © 2005 Wiley Periodicals, Inc. Microwave Opt Technol Lett 45: 491–494, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.20861
doi_str_mv 10.1002/mop.20861
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_mop_20861</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>MOP20861</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3731-ca764fe474b42d377c46b1fb3c0e0faf0feb96f7f2e9aa534fbd7dbc7fe285253</originalsourceid><addsrcrecordid>eNp1kDtPwzAURi0EEqUw8A-8MqT1K3YyogIFUdoOQEfLca7BkJfsSrT_nrQFNqZvOefq6iB0ScmIEsLGdduNGMkkPUIDSvIsYUqSYzQgWZ4mTCh1is5i_CCEcKXYAD0uIbg21KaxgE1jqm30EbcOGxwheIh4HUwTdwgE3A-2bd1VsMG-7qDca7VZ23ffvJ2jE2eqCBc_O0Qvd7fPk_tktpg-TK5nieWK08QaJYUDoUQhWNm_YYUsqCu4JUCcccRBkUunHIPcmJQLV5SqLKxywLKUpXyIrg53bWhjDOB0F3xtwlZToncVdF9B7yv07PjAfvkKtv-D-mmx_DWSg-HjGjZ_hgmfWiquUr2aT_V8zuTrarrUN_wbe5tv8g</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Performance analysis of a series transformer for complex impedance matching</title><source>Wiley Journals</source><creator>Hall, Leonard T. ; Hansen, Hedley J. ; Davis, Bruce R. ; Abbott, Derek</creator><creatorcontrib>Hall, Leonard T. ; Hansen, Hedley J. ; Davis, Bruce R. ; Abbott, Derek</creatorcontrib><description>The ability to match any two complex impedances with a transforming series transmission line of appropriate length is known, but has not been widely studied or deployed. The usefulness of this approach is demonstrated by comparing the performance with that of the series line followed by a quarter‐wavelength transformer, single‐stub tuner, and double‐stub tuner. © 2005 Wiley Periodicals, Inc. Microwave Opt Technol Lett 45: 491–494, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.20861</description><identifier>ISSN: 0895-2477</identifier><identifier>EISSN: 1098-2760</identifier><identifier>DOI: 10.1002/mop.20861</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>impedance matching ; transformer ; transmission lines</subject><ispartof>Microwave and optical technology letters, 2005-06, Vol.45 (6), p.491-494</ispartof><rights>Copyright © 2005 Wiley Periodicals, Inc.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3731-ca764fe474b42d377c46b1fb3c0e0faf0feb96f7f2e9aa534fbd7dbc7fe285253</citedby><cites>FETCH-LOGICAL-c3731-ca764fe474b42d377c46b1fb3c0e0faf0feb96f7f2e9aa534fbd7dbc7fe285253</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fmop.20861$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fmop.20861$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Hall, Leonard T.</creatorcontrib><creatorcontrib>Hansen, Hedley J.</creatorcontrib><creatorcontrib>Davis, Bruce R.</creatorcontrib><creatorcontrib>Abbott, Derek</creatorcontrib><title>Performance analysis of a series transformer for complex impedance matching</title><title>Microwave and optical technology letters</title><addtitle>Microw. Opt. Technol. Lett</addtitle><description>The ability to match any two complex impedances with a transforming series transmission line of appropriate length is known, but has not been widely studied or deployed. The usefulness of this approach is demonstrated by comparing the performance with that of the series line followed by a quarter‐wavelength transformer, single‐stub tuner, and double‐stub tuner. © 2005 Wiley Periodicals, Inc. Microwave Opt Technol Lett 45: 491–494, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.20861</description><subject>impedance matching</subject><subject>transformer</subject><subject>transmission lines</subject><issn>0895-2477</issn><issn>1098-2760</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNp1kDtPwzAURi0EEqUw8A-8MqT1K3YyogIFUdoOQEfLca7BkJfsSrT_nrQFNqZvOefq6iB0ScmIEsLGdduNGMkkPUIDSvIsYUqSYzQgWZ4mTCh1is5i_CCEcKXYAD0uIbg21KaxgE1jqm30EbcOGxwheIh4HUwTdwgE3A-2bd1VsMG-7qDca7VZ23ffvJ2jE2eqCBc_O0Qvd7fPk_tktpg-TK5nieWK08QaJYUDoUQhWNm_YYUsqCu4JUCcccRBkUunHIPcmJQLV5SqLKxywLKUpXyIrg53bWhjDOB0F3xtwlZToncVdF9B7yv07PjAfvkKtv-D-mmx_DWSg-HjGjZ_hgmfWiquUr2aT_V8zuTrarrUN_wbe5tv8g</recordid><startdate>20050620</startdate><enddate>20050620</enddate><creator>Hall, Leonard T.</creator><creator>Hansen, Hedley J.</creator><creator>Davis, Bruce R.</creator><creator>Abbott, Derek</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20050620</creationdate><title>Performance analysis of a series transformer for complex impedance matching</title><author>Hall, Leonard T. ; Hansen, Hedley J. ; Davis, Bruce R. ; Abbott, Derek</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3731-ca764fe474b42d377c46b1fb3c0e0faf0feb96f7f2e9aa534fbd7dbc7fe285253</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>impedance matching</topic><topic>transformer</topic><topic>transmission lines</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Hall, Leonard T.</creatorcontrib><creatorcontrib>Hansen, Hedley J.</creatorcontrib><creatorcontrib>Davis, Bruce R.</creatorcontrib><creatorcontrib>Abbott, Derek</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Microwave and optical technology letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hall, Leonard T.</au><au>Hansen, Hedley J.</au><au>Davis, Bruce R.</au><au>Abbott, Derek</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Performance analysis of a series transformer for complex impedance matching</atitle><jtitle>Microwave and optical technology letters</jtitle><addtitle>Microw. Opt. Technol. Lett</addtitle><date>2005-06-20</date><risdate>2005</risdate><volume>45</volume><issue>6</issue><spage>491</spage><epage>494</epage><pages>491-494</pages><issn>0895-2477</issn><eissn>1098-2760</eissn><abstract>The ability to match any two complex impedances with a transforming series transmission line of appropriate length is known, but has not been widely studied or deployed. The usefulness of this approach is demonstrated by comparing the performance with that of the series line followed by a quarter‐wavelength transformer, single‐stub tuner, and double‐stub tuner. © 2005 Wiley Periodicals, Inc. Microwave Opt Technol Lett 45: 491–494, 2005; Published online in Wiley InterScience (www.interscience.wiley.com). DOI 10.1002/mop.20861</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/mop.20861</doi><tpages>4</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0895-2477
ispartof Microwave and optical technology letters, 2005-06, Vol.45 (6), p.491-494
issn 0895-2477
1098-2760
language eng
recordid cdi_crossref_primary_10_1002_mop_20861
source Wiley Journals
subjects impedance matching
transformer
transmission lines
title Performance analysis of a series transformer for complex impedance matching
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T11%3A09%3A07IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Performance%20analysis%20of%20a%20series%20transformer%20for%20complex%20impedance%20matching&rft.jtitle=Microwave%20and%20optical%20technology%20letters&rft.au=Hall,%20Leonard%20T.&rft.date=2005-06-20&rft.volume=45&rft.issue=6&rft.spage=491&rft.epage=494&rft.pages=491-494&rft.issn=0895-2477&rft.eissn=1098-2760&rft_id=info:doi/10.1002/mop.20861&rft_dat=%3Cwiley_cross%3EMOP20861%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true