An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography

A new multichannel autosampler which can automatically analyze up to twenty samples in sequence has been developed for Curie point pyrolysis – capillary GC. Compared with a previous system [1] the transfer line between the pyroysis unit and chromatograph is shorter, and thus has less dead volume, an...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Journal of high resolution chromatography 1993-06, Vol.16 (6), p.353-357
Hauptverfasser: Onishi, Akira, Endo, Makoto, Uchino, Shigeki, Harashima, Naoto, Oguri, Naoki
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 357
container_issue 6
container_start_page 353
container_title Journal of high resolution chromatography
container_volume 16
creator Onishi, Akira
Endo, Makoto
Uchino, Shigeki
Harashima, Naoto
Oguri, Naoki
description A new multichannel autosampler which can automatically analyze up to twenty samples in sequence has been developed for Curie point pyrolysis – capillary GC. Compared with a previous system [1] the transfer line between the pyroysis unit and chromatograph is shorter, and thus has less dead volume, and can be operated at a higher temperature (300 °C). The relative yields of higher boiling point, highly polar, and thermally labile pyrolysates generated from polymers, and the reproducibility, were better than those obtained from the previous autosampler. To facilitate rapid operation an additional flow controller is installed on the new device to shorten the time taken to purge air from the sampler.
doi_str_mv 10.1002/jhrc.1240160604
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_jhrc_1240160604</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>JHRC1240160604</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3604-b2119e26a25f26fe62e8ca5b1793632a5e9b951aac642eaae67d0ad4a4ab75943</originalsourceid><addsrcrecordid>eNqFkDFPwzAQhS0EEqUws3pgTWs7tlOLqQrQAhVICITEYi6p07ikSWSnKvn3pAoCMTGd7vS-u3cPoXNKRpQQNl7nLh1RxgmVRBJ-gAZUMBpwKieHaEBUKAIZEn6MTrxfE0KU4nSA3qclhm1TedjUhXF4Z5scA_Z55RrcOCh91k0LWxqcVQ7HW2cNritbNrhuXVW03nqcQm2LAlyLV9B1uas20FQrB3XenqKjDApvzr7rEL3cXD_H82DxOLuNp4sgDTu3QcIoVYZJYCJjMjOSmUkKIqGRCmXIQBiVKEEBUsmZATAyWhJYcuCQRELxcIjG_d7UVd47k-na2U3nSVOi9wHpfUD6N6COuOiJGnwKRdY9m1r_g3HCJ0qQTnbZy3a2MO1_W_Xd_Cn-cyToaesb8_lDg_vQMgojoV8fZprF90q9kSs9C78AoZiIeg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography</title><source>Wiley Journals</source><creator>Onishi, Akira ; Endo, Makoto ; Uchino, Shigeki ; Harashima, Naoto ; Oguri, Naoki</creator><creatorcontrib>Onishi, Akira ; Endo, Makoto ; Uchino, Shigeki ; Harashima, Naoto ; Oguri, Naoki</creatorcontrib><description>A new multichannel autosampler which can automatically analyze up to twenty samples in sequence has been developed for Curie point pyrolysis – capillary GC. Compared with a previous system [1] the transfer line between the pyroysis unit and chromatograph is shorter, and thus has less dead volume, and can be operated at a higher temperature (300 °C). The relative yields of higher boiling point, highly polar, and thermally labile pyrolysates generated from polymers, and the reproducibility, were better than those obtained from the previous autosampler. To facilitate rapid operation an additional flow controller is installed on the new device to shorten the time taken to purge air from the sampler.</description><identifier>ISSN: 0935-6304</identifier><identifier>EISSN: 1521-4168</identifier><identifier>DOI: 10.1002/jhrc.1240160604</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Analytical chemistry ; Applied sciences ; Capillary GC Curie point pyrolysis ; Chemistry ; Chromatographic methods and physical methods associated with chromatography ; Exact sciences and technology ; Gas chromatographic methods ; Multichannel autosampler ; Organic polymers ; Physicochemistry of polymers ; Polymer analysis ; Properties and characterization ; Structure, morphology and analysis</subject><ispartof>Journal of high resolution chromatography, 1993-06, Vol.16 (6), p.353-357</ispartof><rights>Copyright © 1993 Dr. Alfred Huethig Publishers</rights><rights>1994 INIST-CNRS</rights><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3604-b2119e26a25f26fe62e8ca5b1793632a5e9b951aac642eaae67d0ad4a4ab75943</citedby><cites>FETCH-LOGICAL-c3604-b2119e26a25f26fe62e8ca5b1793632a5e9b951aac642eaae67d0ad4a4ab75943</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fjhrc.1240160604$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fjhrc.1240160604$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4048950$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Onishi, Akira</creatorcontrib><creatorcontrib>Endo, Makoto</creatorcontrib><creatorcontrib>Uchino, Shigeki</creatorcontrib><creatorcontrib>Harashima, Naoto</creatorcontrib><creatorcontrib>Oguri, Naoki</creatorcontrib><title>An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography</title><title>Journal of high resolution chromatography</title><addtitle>J. High Resol. Chromatogr</addtitle><description>A new multichannel autosampler which can automatically analyze up to twenty samples in sequence has been developed for Curie point pyrolysis – capillary GC. Compared with a previous system [1] the transfer line between the pyroysis unit and chromatograph is shorter, and thus has less dead volume, and can be operated at a higher temperature (300 °C). The relative yields of higher boiling point, highly polar, and thermally labile pyrolysates generated from polymers, and the reproducibility, were better than those obtained from the previous autosampler. To facilitate rapid operation an additional flow controller is installed on the new device to shorten the time taken to purge air from the sampler.</description><subject>Analytical chemistry</subject><subject>Applied sciences</subject><subject>Capillary GC Curie point pyrolysis</subject><subject>Chemistry</subject><subject>Chromatographic methods and physical methods associated with chromatography</subject><subject>Exact sciences and technology</subject><subject>Gas chromatographic methods</subject><subject>Multichannel autosampler</subject><subject>Organic polymers</subject><subject>Physicochemistry of polymers</subject><subject>Polymer analysis</subject><subject>Properties and characterization</subject><subject>Structure, morphology and analysis</subject><issn>0935-6304</issn><issn>1521-4168</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNqFkDFPwzAQhS0EEqUws3pgTWs7tlOLqQrQAhVICITEYi6p07ikSWSnKvn3pAoCMTGd7vS-u3cPoXNKRpQQNl7nLh1RxgmVRBJ-gAZUMBpwKieHaEBUKAIZEn6MTrxfE0KU4nSA3qclhm1TedjUhXF4Z5scA_Z55RrcOCh91k0LWxqcVQ7HW2cNritbNrhuXVW03nqcQm2LAlyLV9B1uas20FQrB3XenqKjDApvzr7rEL3cXD_H82DxOLuNp4sgDTu3QcIoVYZJYCJjMjOSmUkKIqGRCmXIQBiVKEEBUsmZATAyWhJYcuCQRELxcIjG_d7UVd47k-na2U3nSVOi9wHpfUD6N6COuOiJGnwKRdY9m1r_g3HCJ0qQTnbZy3a2MO1_W_Xd_Cn-cyToaesb8_lDg_vQMgojoV8fZprF90q9kSs9C78AoZiIeg</recordid><startdate>199306</startdate><enddate>199306</enddate><creator>Onishi, Akira</creator><creator>Endo, Makoto</creator><creator>Uchino, Shigeki</creator><creator>Harashima, Naoto</creator><creator>Oguri, Naoki</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley-VCH</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199306</creationdate><title>An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography</title><author>Onishi, Akira ; Endo, Makoto ; Uchino, Shigeki ; Harashima, Naoto ; Oguri, Naoki</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3604-b2119e26a25f26fe62e8ca5b1793632a5e9b951aac642eaae67d0ad4a4ab75943</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Analytical chemistry</topic><topic>Applied sciences</topic><topic>Capillary GC Curie point pyrolysis</topic><topic>Chemistry</topic><topic>Chromatographic methods and physical methods associated with chromatography</topic><topic>Exact sciences and technology</topic><topic>Gas chromatographic methods</topic><topic>Multichannel autosampler</topic><topic>Organic polymers</topic><topic>Physicochemistry of polymers</topic><topic>Polymer analysis</topic><topic>Properties and characterization</topic><topic>Structure, morphology and analysis</topic><toplevel>online_resources</toplevel><creatorcontrib>Onishi, Akira</creatorcontrib><creatorcontrib>Endo, Makoto</creatorcontrib><creatorcontrib>Uchino, Shigeki</creatorcontrib><creatorcontrib>Harashima, Naoto</creatorcontrib><creatorcontrib>Oguri, Naoki</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Journal of high resolution chromatography</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Onishi, Akira</au><au>Endo, Makoto</au><au>Uchino, Shigeki</au><au>Harashima, Naoto</au><au>Oguri, Naoki</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography</atitle><jtitle>Journal of high resolution chromatography</jtitle><addtitle>J. High Resol. Chromatogr</addtitle><date>1993-06</date><risdate>1993</risdate><volume>16</volume><issue>6</issue><spage>353</spage><epage>357</epage><pages>353-357</pages><issn>0935-6304</issn><eissn>1521-4168</eissn><abstract>A new multichannel autosampler which can automatically analyze up to twenty samples in sequence has been developed for Curie point pyrolysis – capillary GC. Compared with a previous system [1] the transfer line between the pyroysis unit and chromatograph is shorter, and thus has less dead volume, and can be operated at a higher temperature (300 °C). The relative yields of higher boiling point, highly polar, and thermally labile pyrolysates generated from polymers, and the reproducibility, were better than those obtained from the previous autosampler. To facilitate rapid operation an additional flow controller is installed on the new device to shorten the time taken to purge air from the sampler.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/jhrc.1240160604</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0935-6304
ispartof Journal of high resolution chromatography, 1993-06, Vol.16 (6), p.353-357
issn 0935-6304
1521-4168
language eng
recordid cdi_crossref_primary_10_1002_jhrc_1240160604
source Wiley Journals
subjects Analytical chemistry
Applied sciences
Capillary GC Curie point pyrolysis
Chemistry
Chromatographic methods and physical methods associated with chromatography
Exact sciences and technology
Gas chromatographic methods
Multichannel autosampler
Organic polymers
Physicochemistry of polymers
Polymer analysis
Properties and characterization
Structure, morphology and analysis
title An autosampler with a short transfer line for Curie point pyrolysis capillary gas chromatography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T23%3A46%3A40IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=An%20autosampler%20with%20a%20short%20transfer%20line%20for%20Curie%20point%20pyrolysis%20capillary%20gas%20chromatography&rft.jtitle=Journal%20of%20high%20resolution%20chromatography&rft.au=Onishi,%20Akira&rft.date=1993-06&rft.volume=16&rft.issue=6&rft.spage=353&rft.epage=357&rft.pages=353-357&rft.issn=0935-6304&rft.eissn=1521-4168&rft_id=info:doi/10.1002/jhrc.1240160604&rft_dat=%3Cwiley_cross%3EJHRC1240160604%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true