Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens

In response to spalling of concrete parts, the headrace tunnel was to be strengthened section by section and made fit for the years to come. Since little information was available on the condition of the tunnel and the cause of the spalling, possible damage patterns and causes were analyzed and grou...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Geomechanik und Tunnelbau 2022-10, Vol.15 (5), p.502-514
Hauptverfasser: Schwalt, Markus, Stolz, Daniel
Format: Artikel
Sprache:ger
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 514
container_issue 5
container_start_page 502
container_title Geomechanik und Tunnelbau
container_volume 15
creator Schwalt, Markus
Stolz, Daniel
description In response to spalling of concrete parts, the headrace tunnel was to be strengthened section by section and made fit for the years to come. Since little information was available on the condition of the tunnel and the cause of the spalling, possible damage patterns and causes were analyzed and grouting in combination with concrete rehabilitation were defined as strengthening measures. During a break in operation of approx. 2 months in June 2020, cement injections were tested in grouting trials in different variants to determine their suitability and optimize the parameters and the work to be carried out. The tests and the investigations carried out revealed interesting findings about the condition of the tunnel. The grouting was carried out at low pressure, at different distances and drilling depths, testing important parameters for the subsequent execution and enabling optimization. The porosity of the lining was significantly reduced by grouting, thus improving the quality of the shell. A before‐and‐after measurement with georadar investigation demonstrated the improvement of the lining due to the grouting. A remarkable finding is the combination of the relatively poor quality of the lining concrete, which is due to the construction during World War II, with the practically uncracked and relatively tight lining. It is a testimony to a high level of construction skill that it was possible to create such durable structures with the means available at the time. Nach abgeplatzten Betonteilen im Druckstollen sollte dieser abschnittsweise ertüchtigt und für die weiteren Jahre fit gemacht werden. Da wenig Informationen über den Zustand des Stollens und die Ursache der Abplatzung vorlagen, wurden mögliche Schadensbilder und Ursachen analysiert und Injektionen in Kombination mit einer Betonsanierung als Ertüchtigungsmaßnahme definiert. Innerhalb einer Betriebspause von ca. 2 Monaten wurden im Juni 2020 Zementinjektionen in Verpressversuchen in verschiedenen Varianten getestet, um deren Eignung festzustellen, bzw. die Parameter und auszuführenden Arbeiten zu optimieren. Die Versuche und die dabei gemachten Untersuchungen ergaben interessante Erkenntnisse über den Zustand des Stollens. Die Injektionen erfolgten bei niedrigem Druck, wurden in verschiedenen Abständen und Bohrtiefen ausgeführt und dabei wichtige Parameter für die spätere Ausführung getestet und Optimierungen ermöglicht. Die Porosität der Auskleidung konnte dabei wesentlich reduziert und damit die Qua
doi_str_mv 10.1002/geot.202200049
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1002_geot_202200049</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1002_geot_202200049</sourcerecordid><originalsourceid>FETCH-LOGICAL-c109t-eea8be2e8bfcf0823b42642570c41bff59dc4e4a88fe5b9de7f14c98bef68eab3</originalsourceid><addsrcrecordid>eNo9kL1OwzAUhS0EElXpyuwHIMV2nMQeUSktohILP2NkO9dpaEiqawdEn42NF6MVqNM5w_nO8BFyydmUMyaua-jjVDAhGGNSn5ARV3mWFKnSp8eei3MyCeFtP2Epl0WRj8jiAY2Pn4Ab-trEXWeGK_oCuEUI4QMwDG4NdDcgnWP8-Xbr2NRDV9MKAr3FwW1C7NsWunBBzrxpA0z-c0ye7-ZPs2Wyelzcz25WieNMxwTAKAsClPXOMyVSK0UuRVYwJ7n1PtOVkyCNUh4yqysoPJdO7xmfKzA2HZPp36_DPgQEX26xeTf4VXJWHkyUBxPl0UT6C5HyVTA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens</title><source>Wiley Online Library - AutoHoldings Journals</source><creator>Schwalt, Markus ; Stolz, Daniel</creator><creatorcontrib>Schwalt, Markus ; Stolz, Daniel</creatorcontrib><description>In response to spalling of concrete parts, the headrace tunnel was to be strengthened section by section and made fit for the years to come. Since little information was available on the condition of the tunnel and the cause of the spalling, possible damage patterns and causes were analyzed and grouting in combination with concrete rehabilitation were defined as strengthening measures. During a break in operation of approx. 2 months in June 2020, cement injections were tested in grouting trials in different variants to determine their suitability and optimize the parameters and the work to be carried out. The tests and the investigations carried out revealed interesting findings about the condition of the tunnel. The grouting was carried out at low pressure, at different distances and drilling depths, testing important parameters for the subsequent execution and enabling optimization. The porosity of the lining was significantly reduced by grouting, thus improving the quality of the shell. A before‐and‐after measurement with georadar investigation demonstrated the improvement of the lining due to the grouting. A remarkable finding is the combination of the relatively poor quality of the lining concrete, which is due to the construction during World War II, with the practically uncracked and relatively tight lining. It is a testimony to a high level of construction skill that it was possible to create such durable structures with the means available at the time. Nach abgeplatzten Betonteilen im Druckstollen sollte dieser abschnittsweise ertüchtigt und für die weiteren Jahre fit gemacht werden. Da wenig Informationen über den Zustand des Stollens und die Ursache der Abplatzung vorlagen, wurden mögliche Schadensbilder und Ursachen analysiert und Injektionen in Kombination mit einer Betonsanierung als Ertüchtigungsmaßnahme definiert. Innerhalb einer Betriebspause von ca. 2 Monaten wurden im Juni 2020 Zementinjektionen in Verpressversuchen in verschiedenen Varianten getestet, um deren Eignung festzustellen, bzw. die Parameter und auszuführenden Arbeiten zu optimieren. Die Versuche und die dabei gemachten Untersuchungen ergaben interessante Erkenntnisse über den Zustand des Stollens. Die Injektionen erfolgten bei niedrigem Druck, wurden in verschiedenen Abständen und Bohrtiefen ausgeführt und dabei wichtige Parameter für die spätere Ausführung getestet und Optimierungen ermöglicht. Die Porosität der Auskleidung konnte dabei wesentlich reduziert und damit die Qualität der Schale verbessert werden. Mit einer Vorher‐nachher‐messung mit Georadar konnte die Verbesserung der Auskleidung durch die Injektion nachgewiesen werden. Eine bemerkenswerte Erkenntnis ist die Kombination aus verhältnismäßig bescheidener Qualität des Auskleidungsbetons, die dem Bau während des Zweiten Weltkriegs geschuldet ist, mit der praktisch ungerissenen und relativ dichten Auskleidung. Es zeugt von einer hohen Baukunst, dass mit den damals verfügbaren Mitteln so dauerhafte Bauwerke erstellt werden konnten.</description><identifier>ISSN: 1865-7362</identifier><identifier>EISSN: 1865-7389</identifier><identifier>DOI: 10.1002/geot.202200049</identifier><language>ger</language><ispartof>Geomechanik und Tunnelbau, 2022-10, Vol.15 (5), p.502-514</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Schwalt, Markus</creatorcontrib><creatorcontrib>Stolz, Daniel</creatorcontrib><title>Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens</title><title>Geomechanik und Tunnelbau</title><description>In response to spalling of concrete parts, the headrace tunnel was to be strengthened section by section and made fit for the years to come. Since little information was available on the condition of the tunnel and the cause of the spalling, possible damage patterns and causes were analyzed and grouting in combination with concrete rehabilitation were defined as strengthening measures. During a break in operation of approx. 2 months in June 2020, cement injections were tested in grouting trials in different variants to determine their suitability and optimize the parameters and the work to be carried out. The tests and the investigations carried out revealed interesting findings about the condition of the tunnel. The grouting was carried out at low pressure, at different distances and drilling depths, testing important parameters for the subsequent execution and enabling optimization. The porosity of the lining was significantly reduced by grouting, thus improving the quality of the shell. A before‐and‐after measurement with georadar investigation demonstrated the improvement of the lining due to the grouting. A remarkable finding is the combination of the relatively poor quality of the lining concrete, which is due to the construction during World War II, with the practically uncracked and relatively tight lining. It is a testimony to a high level of construction skill that it was possible to create such durable structures with the means available at the time. Nach abgeplatzten Betonteilen im Druckstollen sollte dieser abschnittsweise ertüchtigt und für die weiteren Jahre fit gemacht werden. Da wenig Informationen über den Zustand des Stollens und die Ursache der Abplatzung vorlagen, wurden mögliche Schadensbilder und Ursachen analysiert und Injektionen in Kombination mit einer Betonsanierung als Ertüchtigungsmaßnahme definiert. Innerhalb einer Betriebspause von ca. 2 Monaten wurden im Juni 2020 Zementinjektionen in Verpressversuchen in verschiedenen Varianten getestet, um deren Eignung festzustellen, bzw. die Parameter und auszuführenden Arbeiten zu optimieren. Die Versuche und die dabei gemachten Untersuchungen ergaben interessante Erkenntnisse über den Zustand des Stollens. Die Injektionen erfolgten bei niedrigem Druck, wurden in verschiedenen Abständen und Bohrtiefen ausgeführt und dabei wichtige Parameter für die spätere Ausführung getestet und Optimierungen ermöglicht. Die Porosität der Auskleidung konnte dabei wesentlich reduziert und damit die Qualität der Schale verbessert werden. Mit einer Vorher‐nachher‐messung mit Georadar konnte die Verbesserung der Auskleidung durch die Injektion nachgewiesen werden. Eine bemerkenswerte Erkenntnis ist die Kombination aus verhältnismäßig bescheidener Qualität des Auskleidungsbetons, die dem Bau während des Zweiten Weltkriegs geschuldet ist, mit der praktisch ungerissenen und relativ dichten Auskleidung. Es zeugt von einer hohen Baukunst, dass mit den damals verfügbaren Mitteln so dauerhafte Bauwerke erstellt werden konnten.</description><issn>1865-7362</issn><issn>1865-7389</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNo9kL1OwzAUhS0EElXpyuwHIMV2nMQeUSktohILP2NkO9dpaEiqawdEn42NF6MVqNM5w_nO8BFyydmUMyaua-jjVDAhGGNSn5ARV3mWFKnSp8eei3MyCeFtP2Epl0WRj8jiAY2Pn4Ab-trEXWeGK_oCuEUI4QMwDG4NdDcgnWP8-Xbr2NRDV9MKAr3FwW1C7NsWunBBzrxpA0z-c0ye7-ZPs2Wyelzcz25WieNMxwTAKAsClPXOMyVSK0UuRVYwJ7n1PtOVkyCNUh4yqysoPJdO7xmfKzA2HZPp36_DPgQEX26xeTf4VXJWHkyUBxPl0UT6C5HyVTA</recordid><startdate>202210</startdate><enddate>202210</enddate><creator>Schwalt, Markus</creator><creator>Stolz, Daniel</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202210</creationdate><title>Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens</title><author>Schwalt, Markus ; Stolz, Daniel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c109t-eea8be2e8bfcf0823b42642570c41bff59dc4e4a88fe5b9de7f14c98bef68eab3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>ger</language><creationdate>2022</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Schwalt, Markus</creatorcontrib><creatorcontrib>Stolz, Daniel</creatorcontrib><collection>CrossRef</collection><jtitle>Geomechanik und Tunnelbau</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Schwalt, Markus</au><au>Stolz, Daniel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens</atitle><jtitle>Geomechanik und Tunnelbau</jtitle><date>2022-10</date><risdate>2022</risdate><volume>15</volume><issue>5</issue><spage>502</spage><epage>514</epage><pages>502-514</pages><issn>1865-7362</issn><eissn>1865-7389</eissn><abstract>In response to spalling of concrete parts, the headrace tunnel was to be strengthened section by section and made fit for the years to come. Since little information was available on the condition of the tunnel and the cause of the spalling, possible damage patterns and causes were analyzed and grouting in combination with concrete rehabilitation were defined as strengthening measures. During a break in operation of approx. 2 months in June 2020, cement injections were tested in grouting trials in different variants to determine their suitability and optimize the parameters and the work to be carried out. The tests and the investigations carried out revealed interesting findings about the condition of the tunnel. The grouting was carried out at low pressure, at different distances and drilling depths, testing important parameters for the subsequent execution and enabling optimization. The porosity of the lining was significantly reduced by grouting, thus improving the quality of the shell. A before‐and‐after measurement with georadar investigation demonstrated the improvement of the lining due to the grouting. A remarkable finding is the combination of the relatively poor quality of the lining concrete, which is due to the construction during World War II, with the practically uncracked and relatively tight lining. It is a testimony to a high level of construction skill that it was possible to create such durable structures with the means available at the time. Nach abgeplatzten Betonteilen im Druckstollen sollte dieser abschnittsweise ertüchtigt und für die weiteren Jahre fit gemacht werden. Da wenig Informationen über den Zustand des Stollens und die Ursache der Abplatzung vorlagen, wurden mögliche Schadensbilder und Ursachen analysiert und Injektionen in Kombination mit einer Betonsanierung als Ertüchtigungsmaßnahme definiert. Innerhalb einer Betriebspause von ca. 2 Monaten wurden im Juni 2020 Zementinjektionen in Verpressversuchen in verschiedenen Varianten getestet, um deren Eignung festzustellen, bzw. die Parameter und auszuführenden Arbeiten zu optimieren. Die Versuche und die dabei gemachten Untersuchungen ergaben interessante Erkenntnisse über den Zustand des Stollens. Die Injektionen erfolgten bei niedrigem Druck, wurden in verschiedenen Abständen und Bohrtiefen ausgeführt und dabei wichtige Parameter für die spätere Ausführung getestet und Optimierungen ermöglicht. Die Porosität der Auskleidung konnte dabei wesentlich reduziert und damit die Qualität der Schale verbessert werden. Mit einer Vorher‐nachher‐messung mit Georadar konnte die Verbesserung der Auskleidung durch die Injektion nachgewiesen werden. Eine bemerkenswerte Erkenntnis ist die Kombination aus verhältnismäßig bescheidener Qualität des Auskleidungsbetons, die dem Bau während des Zweiten Weltkriegs geschuldet ist, mit der praktisch ungerissenen und relativ dichten Auskleidung. Es zeugt von einer hohen Baukunst, dass mit den damals verfügbaren Mitteln so dauerhafte Bauwerke erstellt werden konnten.</abstract><doi>10.1002/geot.202200049</doi><tpages>13</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1865-7362
ispartof Geomechanik und Tunnelbau, 2022-10, Vol.15 (5), p.502-514
issn 1865-7362
1865-7389
language ger
recordid cdi_crossref_primary_10_1002_geot_202200049
source Wiley Online Library - AutoHoldings Journals
title Kraftwerk Witznau, Verpressversuche zur Ertüchtigung des Druckstollens
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T14%3A52%3A36IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Kraftwerk%20Witznau,%20Verpressversuche%20zur%20Ert%C3%BCchtigung%20des%20Druckstollens&rft.jtitle=Geomechanik%20und%20Tunnelbau&rft.au=Schwalt,%20Markus&rft.date=2022-10&rft.volume=15&rft.issue=5&rft.spage=502&rft.epage=514&rft.pages=502-514&rft.issn=1865-7362&rft.eissn=1865-7389&rft_id=info:doi/10.1002/geot.202200049&rft_dat=%3Ccrossref%3E10_1002_geot_202200049%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true