New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis
The development of analytical methods for the rapid detection of noxious species in forensic, environmental and biological samples is a global trend. This work reports a new, portable and low‐cost electroanalytical method for the ultrasensitive detection of bromadiolone using pencil graphite electro...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 2024-08 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | |
creator | Conrado, Thaylor Teixeira Pedão, Evandro Rodrigo Ferreira, Valdir Souza da Silva, Rodrigo Amorim Bezerra Petroni, Jacqueline Marques Lucca, Bruno Gabriel |
description | The development of analytical methods for the rapid detection of noxious species in forensic, environmental and biological samples is a global trend. This work reports a new, portable and low‐cost electroanalytical method for the ultrasensitive detection of bromadiolone using pencil graphite electrode (PGE) and square‐wave adsorptive stripping voltammetry (SWAdSV). Bromadiolone exhibited an irreversible cathodic peak at around −0.8 V in acid medium (2.5 to 5.5), which was unreported in literature until now. Considering this novel electrochemical behavior, a redox reaction mechanism for bromadiolone reduction on PGE is proposed. The limit of detection (LOD) obtained was 0.50 nmol L −1 , which is close or lower than those obtained in some chromatographic methods utilized for analyzing biological samples. This LOD is also below the value recommended by the World Health Organization (WHO) regarding analytical methods employed to detect bromadiolone in environmental/biological samples. A linear response was observed in the concentration range from 2.0 to 100.0 nmol L −1 . Quantitative assays performed in spiked samples of surface water and synthetic urine suggested good accuracy (recoveries between 93 and 107 %) and great precision (relative standard deviations were ≤3.9 %). Furthermore, the method was successfully applied for the screening of bromadiolone in real forensic samples, which is an approach unexplored in previous works. In this sense, the proposed PGE‐SWAdSV method described here shows great potential for the rapid and sensitive detection of bromadiolone in forensic, biological and environmental fields. |
doi_str_mv | 10.1002/elan.202400146 |
format | Article |
fullrecord | <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_202400146</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1002_elan_202400146</sourcerecordid><originalsourceid>FETCH-LOGICAL-c124t-2e3e41bed9b76c6937332d8bd57e58e8caedfdd335625cb159ba8266844fc44f3</originalsourceid><addsrcrecordid>eNo9UElOAzEQtBBIhMCVsz8wwdts3KKITYrgAueRx-5JjDx2ZDsJ3HgCD-I1vIRJAhxK3apuVZUKoUtKJpQQdgVWugkjTBBCRXGERjRnNBOU1MfDTgTJCK_LU3QW4yshpC5EPUJfj7DFAbR_wy0s5cb4gKXTGCyoFLxaQm-UtDiCi8YtsO-GczLKy8V68Es4eA07wmjAbfC91MZb7wCv9__Wb78_PpWPCS-CXC1Ngj9tDdd46vDapiD38slsACfvLe6GFAN2pDrEcRsTvOsHqyGMdNK-RxPP0UknbYSL3zlGL7c3z7P7bP509zCbzjNFmUgZAw6CtqDrtixUUfOSc6arVucl5BVUSoLutOY8L1iuWprXraxYUVRCdGoAH6PJQVcFH2OArlkF08vw3lDS7Lpvdt03_93zH9fxgDA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis</title><source>Wiley Journals</source><creator>Conrado, Thaylor Teixeira ; Pedão, Evandro Rodrigo ; Ferreira, Valdir Souza ; da Silva, Rodrigo Amorim Bezerra ; Petroni, Jacqueline Marques ; Lucca, Bruno Gabriel</creator><creatorcontrib>Conrado, Thaylor Teixeira ; Pedão, Evandro Rodrigo ; Ferreira, Valdir Souza ; da Silva, Rodrigo Amorim Bezerra ; Petroni, Jacqueline Marques ; Lucca, Bruno Gabriel</creatorcontrib><description>The development of analytical methods for the rapid detection of noxious species in forensic, environmental and biological samples is a global trend. This work reports a new, portable and low‐cost electroanalytical method for the ultrasensitive detection of bromadiolone using pencil graphite electrode (PGE) and square‐wave adsorptive stripping voltammetry (SWAdSV). Bromadiolone exhibited an irreversible cathodic peak at around −0.8 V in acid medium (2.5 to 5.5), which was unreported in literature until now. Considering this novel electrochemical behavior, a redox reaction mechanism for bromadiolone reduction on PGE is proposed. The limit of detection (LOD) obtained was 0.50 nmol L −1 , which is close or lower than those obtained in some chromatographic methods utilized for analyzing biological samples. This LOD is also below the value recommended by the World Health Organization (WHO) regarding analytical methods employed to detect bromadiolone in environmental/biological samples. A linear response was observed in the concentration range from 2.0 to 100.0 nmol L −1 . Quantitative assays performed in spiked samples of surface water and synthetic urine suggested good accuracy (recoveries between 93 and 107 %) and great precision (relative standard deviations were ≤3.9 %). Furthermore, the method was successfully applied for the screening of bromadiolone in real forensic samples, which is an approach unexplored in previous works. In this sense, the proposed PGE‐SWAdSV method described here shows great potential for the rapid and sensitive detection of bromadiolone in forensic, biological and environmental fields.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.202400146</identifier><language>eng</language><ispartof>Electroanalysis (New York, N.Y.), 2024-08</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c124t-2e3e41bed9b76c6937332d8bd57e58e8caedfdd335625cb159ba8266844fc44f3</cites><orcidid>0000-0002-5782-6845</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Conrado, Thaylor Teixeira</creatorcontrib><creatorcontrib>Pedão, Evandro Rodrigo</creatorcontrib><creatorcontrib>Ferreira, Valdir Souza</creatorcontrib><creatorcontrib>da Silva, Rodrigo Amorim Bezerra</creatorcontrib><creatorcontrib>Petroni, Jacqueline Marques</creatorcontrib><creatorcontrib>Lucca, Bruno Gabriel</creatorcontrib><title>New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis</title><title>Electroanalysis (New York, N.Y.)</title><description>The development of analytical methods for the rapid detection of noxious species in forensic, environmental and biological samples is a global trend. This work reports a new, portable and low‐cost electroanalytical method for the ultrasensitive detection of bromadiolone using pencil graphite electrode (PGE) and square‐wave adsorptive stripping voltammetry (SWAdSV). Bromadiolone exhibited an irreversible cathodic peak at around −0.8 V in acid medium (2.5 to 5.5), which was unreported in literature until now. Considering this novel electrochemical behavior, a redox reaction mechanism for bromadiolone reduction on PGE is proposed. The limit of detection (LOD) obtained was 0.50 nmol L −1 , which is close or lower than those obtained in some chromatographic methods utilized for analyzing biological samples. This LOD is also below the value recommended by the World Health Organization (WHO) regarding analytical methods employed to detect bromadiolone in environmental/biological samples. A linear response was observed in the concentration range from 2.0 to 100.0 nmol L −1 . Quantitative assays performed in spiked samples of surface water and synthetic urine suggested good accuracy (recoveries between 93 and 107 %) and great precision (relative standard deviations were ≤3.9 %). Furthermore, the method was successfully applied for the screening of bromadiolone in real forensic samples, which is an approach unexplored in previous works. In this sense, the proposed PGE‐SWAdSV method described here shows great potential for the rapid and sensitive detection of bromadiolone in forensic, biological and environmental fields.</description><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNo9UElOAzEQtBBIhMCVsz8wwdts3KKITYrgAueRx-5JjDx2ZDsJ3HgCD-I1vIRJAhxK3apuVZUKoUtKJpQQdgVWugkjTBBCRXGERjRnNBOU1MfDTgTJCK_LU3QW4yshpC5EPUJfj7DFAbR_wy0s5cb4gKXTGCyoFLxaQm-UtDiCi8YtsO-GczLKy8V68Es4eA07wmjAbfC91MZb7wCv9__Wb78_PpWPCS-CXC1Ngj9tDdd46vDapiD38slsACfvLe6GFAN2pDrEcRsTvOsHqyGMdNK-RxPP0UknbYSL3zlGL7c3z7P7bP509zCbzjNFmUgZAw6CtqDrtixUUfOSc6arVucl5BVUSoLutOY8L1iuWprXraxYUVRCdGoAH6PJQVcFH2OArlkF08vw3lDS7Lpvdt03_93zH9fxgDA</recordid><startdate>20240802</startdate><enddate>20240802</enddate><creator>Conrado, Thaylor Teixeira</creator><creator>Pedão, Evandro Rodrigo</creator><creator>Ferreira, Valdir Souza</creator><creator>da Silva, Rodrigo Amorim Bezerra</creator><creator>Petroni, Jacqueline Marques</creator><creator>Lucca, Bruno Gabriel</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-5782-6845</orcidid></search><sort><creationdate>20240802</creationdate><title>New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis</title><author>Conrado, Thaylor Teixeira ; Pedão, Evandro Rodrigo ; Ferreira, Valdir Souza ; da Silva, Rodrigo Amorim Bezerra ; Petroni, Jacqueline Marques ; Lucca, Bruno Gabriel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c124t-2e3e41bed9b76c6937332d8bd57e58e8caedfdd335625cb159ba8266844fc44f3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Conrado, Thaylor Teixeira</creatorcontrib><creatorcontrib>Pedão, Evandro Rodrigo</creatorcontrib><creatorcontrib>Ferreira, Valdir Souza</creatorcontrib><creatorcontrib>da Silva, Rodrigo Amorim Bezerra</creatorcontrib><creatorcontrib>Petroni, Jacqueline Marques</creatorcontrib><creatorcontrib>Lucca, Bruno Gabriel</creatorcontrib><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Conrado, Thaylor Teixeira</au><au>Pedão, Evandro Rodrigo</au><au>Ferreira, Valdir Souza</au><au>da Silva, Rodrigo Amorim Bezerra</au><au>Petroni, Jacqueline Marques</au><au>Lucca, Bruno Gabriel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><date>2024-08-02</date><risdate>2024</risdate><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The development of analytical methods for the rapid detection of noxious species in forensic, environmental and biological samples is a global trend. This work reports a new, portable and low‐cost electroanalytical method for the ultrasensitive detection of bromadiolone using pencil graphite electrode (PGE) and square‐wave adsorptive stripping voltammetry (SWAdSV). Bromadiolone exhibited an irreversible cathodic peak at around −0.8 V in acid medium (2.5 to 5.5), which was unreported in literature until now. Considering this novel electrochemical behavior, a redox reaction mechanism for bromadiolone reduction on PGE is proposed. The limit of detection (LOD) obtained was 0.50 nmol L −1 , which is close or lower than those obtained in some chromatographic methods utilized for analyzing biological samples. This LOD is also below the value recommended by the World Health Organization (WHO) regarding analytical methods employed to detect bromadiolone in environmental/biological samples. A linear response was observed in the concentration range from 2.0 to 100.0 nmol L −1 . Quantitative assays performed in spiked samples of surface water and synthetic urine suggested good accuracy (recoveries between 93 and 107 %) and great precision (relative standard deviations were ≤3.9 %). Furthermore, the method was successfully applied for the screening of bromadiolone in real forensic samples, which is an approach unexplored in previous works. In this sense, the proposed PGE‐SWAdSV method described here shows great potential for the rapid and sensitive detection of bromadiolone in forensic, biological and environmental fields.</abstract><doi>10.1002/elan.202400146</doi><orcidid>https://orcid.org/0000-0002-5782-6845</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2024-08 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_crossref_primary_10_1002_elan_202400146 |
source | Wiley Journals |
title | New redox behavior and electrochemical sensing of anticoagulant rodenticide bromadiolone using low‐cost graphite electrode: An ultrasensitive tool for forensic and environmental analysis |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-26T01%3A10%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=New%20redox%20behavior%20and%20electrochemical%20sensing%20of%20anticoagulant%20rodenticide%20bromadiolone%20using%20low%E2%80%90cost%20graphite%20electrode:%20An%20ultrasensitive%20tool%20for%20forensic%20and%20environmental%20analysis&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Conrado,%20Thaylor%20Teixeira&rft.date=2024-08-02&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.202400146&rft_dat=%3Ccrossref%3E10_1002_elan_202400146%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |