Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets

The ability to obtain accurate analytical results without sample pre‐treatment or derivatization is a key element for an eco‐friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti‐cholinergic drug Procyclidin...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electroanalysis (New York, N.Y.) N.Y.), 2024-08, Vol.36 (8), p.n/a
Hauptverfasser: Gaber, Radwa Ahmed, Hassan, Nagiba Y., Ramadan, Nesrin K., Ragab, Mona T.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 8
container_start_page
container_title Electroanalysis (New York, N.Y.)
container_volume 36
creator Gaber, Radwa Ahmed
Hassan, Nagiba Y.
Ramadan, Nesrin K.
Ragab, Mona T.
description The ability to obtain accurate analytical results without sample pre‐treatment or derivatization is a key element for an eco‐friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti‐cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre‐treatment. Firstly, screening of four ionophore‐doped polyvinyl chloride‐based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene‐doped membrane exhibited the optimum results. Then optimization was carried out by designing screen‐printed and glassy carbon solid‐contact ion‐selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen‐printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10−5–1×10−2 M and the theoretical limit of detection was 6.3×10−6 M. Finally, it was used in applications such as in‐line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre‐treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).
doi_str_mv 10.1002/elan.202300363
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_202300363</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ELAN202300363</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1743-a6210a281ab27ef9ba31ced67a0f47ce348ff29484831a31fa1732f6b2f3329c3</originalsourceid><addsrcrecordid>eNqFkL1OwzAUhS0EEqWwMvsFUq5_SOKxqgpFqmAA5shxbDBy48o2oG48Aiuvx5PgtKiMDFe-1-c7ZzgInROYEAB6oZ3sJxQoA2AlO0AjcklJwQmIw7wDhwKYqI7RSYwvACBKLkbo6947231_fCrfJ6kStr7PV9ROq2TfNI66jz5gkyc9a9zZkAXc6aTDyvYyZR57g9fBq43KUbbXeDFzWPYdluu1s2rP2CHZDUBnY_TudStkp7H592mLpIiTbJ1O8RQdGemiPvt9x-jxav4wWxTLu-ub2XRZKFJxVsiSEpC0JrKllTailYwo3ZWVBMMrpRmvjaGC17xmJGtGkopRU7bUMEaFYmM02eWq4GMM2jTrYFcybBoCzVBsMxTb7IvNBrEzvFunN__QzXw5vf3z_gBcEYPn</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Gaber, Radwa Ahmed ; Hassan, Nagiba Y. ; Ramadan, Nesrin K. ; Ragab, Mona T.</creator><creatorcontrib>Gaber, Radwa Ahmed ; Hassan, Nagiba Y. ; Ramadan, Nesrin K. ; Ragab, Mona T.</creatorcontrib><description>The ability to obtain accurate analytical results without sample pre‐treatment or derivatization is a key element for an eco‐friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti‐cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre‐treatment. Firstly, screening of four ionophore‐doped polyvinyl chloride‐based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene‐doped membrane exhibited the optimum results. Then optimization was carried out by designing screen‐printed and glassy carbon solid‐contact ion‐selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen‐printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10−5–1×10−2 M and the theoretical limit of detection was 6.3×10−6 M. Finally, it was used in applications such as in‐line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre‐treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.202300363</identifier><language>eng</language><subject>graphene ; green analytical chemistry ; procyclidine hydrochloride ; screen-printed electrode ; solid-contact ion selective electrodes</subject><ispartof>Electroanalysis (New York, N.Y.), 2024-08, Vol.36 (8), p.n/a</ispartof><rights>2024 Wiley-VCH GmbH</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c1743-a6210a281ab27ef9ba31ced67a0f47ce348ff29484831a31fa1732f6b2f3329c3</cites><orcidid>0009-0001-9028-5833 ; 0000-0002-9004-8037</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Felan.202300363$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.202300363$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27903,27904,45553,45554</link.rule.ids></links><search><creatorcontrib>Gaber, Radwa Ahmed</creatorcontrib><creatorcontrib>Hassan, Nagiba Y.</creatorcontrib><creatorcontrib>Ramadan, Nesrin K.</creatorcontrib><creatorcontrib>Ragab, Mona T.</creatorcontrib><title>Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets</title><title>Electroanalysis (New York, N.Y.)</title><description>The ability to obtain accurate analytical results without sample pre‐treatment or derivatization is a key element for an eco‐friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti‐cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre‐treatment. Firstly, screening of four ionophore‐doped polyvinyl chloride‐based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene‐doped membrane exhibited the optimum results. Then optimization was carried out by designing screen‐printed and glassy carbon solid‐contact ion‐selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen‐printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10−5–1×10−2 M and the theoretical limit of detection was 6.3×10−6 M. Finally, it was used in applications such as in‐line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre‐treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).</description><subject>graphene</subject><subject>green analytical chemistry</subject><subject>procyclidine hydrochloride</subject><subject>screen-printed electrode</subject><subject>solid-contact ion selective electrodes</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNqFkL1OwzAUhS0EEqWwMvsFUq5_SOKxqgpFqmAA5shxbDBy48o2oG48Aiuvx5PgtKiMDFe-1-c7ZzgInROYEAB6oZ3sJxQoA2AlO0AjcklJwQmIw7wDhwKYqI7RSYwvACBKLkbo6947231_fCrfJ6kStr7PV9ROq2TfNI66jz5gkyc9a9zZkAXc6aTDyvYyZR57g9fBq43KUbbXeDFzWPYdluu1s2rP2CHZDUBnY_TudStkp7H592mLpIiTbJ1O8RQdGemiPvt9x-jxav4wWxTLu-ub2XRZKFJxVsiSEpC0JrKllTailYwo3ZWVBMMrpRmvjaGC17xmJGtGkopRU7bUMEaFYmM02eWq4GMM2jTrYFcybBoCzVBsMxTb7IvNBrEzvFunN__QzXw5vf3z_gBcEYPn</recordid><startdate>202408</startdate><enddate>202408</enddate><creator>Gaber, Radwa Ahmed</creator><creator>Hassan, Nagiba Y.</creator><creator>Ramadan, Nesrin K.</creator><creator>Ragab, Mona T.</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0009-0001-9028-5833</orcidid><orcidid>https://orcid.org/0000-0002-9004-8037</orcidid></search><sort><creationdate>202408</creationdate><title>Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets</title><author>Gaber, Radwa Ahmed ; Hassan, Nagiba Y. ; Ramadan, Nesrin K. ; Ragab, Mona T.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1743-a6210a281ab27ef9ba31ced67a0f47ce348ff29484831a31fa1732f6b2f3329c3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>graphene</topic><topic>green analytical chemistry</topic><topic>procyclidine hydrochloride</topic><topic>screen-printed electrode</topic><topic>solid-contact ion selective electrodes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gaber, Radwa Ahmed</creatorcontrib><creatorcontrib>Hassan, Nagiba Y.</creatorcontrib><creatorcontrib>Ramadan, Nesrin K.</creatorcontrib><creatorcontrib>Ragab, Mona T.</creatorcontrib><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gaber, Radwa Ahmed</au><au>Hassan, Nagiba Y.</au><au>Ramadan, Nesrin K.</au><au>Ragab, Mona T.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><date>2024-08</date><risdate>2024</risdate><volume>36</volume><issue>8</issue><epage>n/a</epage><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The ability to obtain accurate analytical results without sample pre‐treatment or derivatization is a key element for an eco‐friendly method of analysis. In this work, green electro analytical method was developed and evaluated for the selective determination of the anti‐cholinergic drug Procyclidine Hydrochloride in both pure and dosage forms as well as in dissolution medium without sample pre‐treatment. Firstly, screening of four ionophore‐doped polyvinyl chloride‐based membranes were conducted to detect the one with highest affinity towards the studied drug. Accordingly, calix[4]arene‐doped membrane exhibited the optimum results. Then optimization was carried out by designing screen‐printed and glassy carbon solid‐contact ion‐selective electrodes with multiwall carbon nanotube and graphene nanocomposite as ion to electron transducers. The fabricated screen‐printed sensor with graphene nanocomposite was characterized according to IUPAC recommendations. It acquired the fastest and most stable response, along with thermal stability up to 30 °C. It also displayed a slope of 43.9±0.2 mV/decade in a pH range of 2–5. The proposed sensor successfully obtained a linear range of 1×10−5–1×10−2 M and the theoretical limit of detection was 6.3×10−6 M. Finally, it was used in applications such as in‐line dissolution monitoring and quantification of procyclidine in its dosage form without prior sample pre‐treatment or derivatization steps. Furthermore, the graphene nanocomposite transducer has been imaged by Scanning Electron Microscope (SEM).</abstract><doi>10.1002/elan.202300363</doi><tpages>12</tpages><orcidid>https://orcid.org/0009-0001-9028-5833</orcidid><orcidid>https://orcid.org/0000-0002-9004-8037</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 1040-0397
ispartof Electroanalysis (New York, N.Y.), 2024-08, Vol.36 (8), p.n/a
issn 1040-0397
1521-4109
language eng
recordid cdi_crossref_primary_10_1002_elan_202300363
source Wiley Online Library Journals Frontfile Complete
subjects graphene
green analytical chemistry
procyclidine hydrochloride
screen-printed electrode
solid-contact ion selective electrodes
title Solid‐contact ion‐selective sensor for the direct determination of procyclidine HCl and application of in‐line dissolution profiling of its tablets
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T23%3A49%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Solid%E2%80%90contact%20ion%E2%80%90selective%20sensor%20for%20the%20direct%20determination%20of%20procyclidine%20HCl%20and%20application%20of%20in%E2%80%90line%20dissolution%20profiling%20of%20its%20tablets&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Gaber,%20Radwa%20Ahmed&rft.date=2024-08&rft.volume=36&rft.issue=8&rft.epage=n/a&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.202300363&rft_dat=%3Cwiley_cross%3EELAN202300363%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true