A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix
The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 2010-08, Vol.22 (16), p.1894-1900 |
---|---|
Hauptverfasser: | , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1900 |
---|---|
container_issue | 16 |
container_start_page | 1894 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 22 |
creator | Petković, B. B. Sovilj, S. P. Budimir, M. V. Simonović, R. M. Jovanović, V. M. |
description | The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10−1–1.0×10−6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10−7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples. |
doi_str_mv | 10.1002/elan.201000053 |
format | Article |
fullrecord | <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_201000053</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ELAN201000053</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3933-787345596b37f05fdbd9a0c2bc2099a18ae30b464de74267023111452d7e5cc83</originalsourceid><addsrcrecordid>eNqFkMtKA0EQRQdR8Ll13UuFdOzn9PQyhqjBGMXnsun0VLB1nAndgzqu_A4_Q__IL3FiRNwJRdUtuKcKbpJsU9KlhLA9KGzZZaTVhEi-lKxRySgWlOjlVhNBMOFarSbrMd61Fp0KvZa89VC_ms0g7AyHu2hYlfgCCnC1fwR0VtVQ1r56gDp4hy6gjFVA-zZCjqoSjTvjz9f3efv4VovCl63b3vu4w_CsCT5vipa_bYpdTDuik3UoxfXcYl-sa1xRfS85OFsC8iU6u-6jE9s-fN5MVqa2iLD1MzeSq4PBZf8Ij04Ph_3eCDuuOccqU1xIqdMJV1Mip_kk15Y4NnGMaG1pZoGTiUhFDkqwVBHGKaVCslyBdC7jG0l3cdeFKsYAUzML_sGGxlBi5smaebLmN9kW0AvgyRfQ_OM2g1Fv_JfFC9bHGp5_WRvuTaq4kuZmfGiYusnSYyHNOf8COgyQDQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix</title><source>Wiley-Blackwell Journals</source><creator>Petković, B. B. ; Sovilj, S. P. ; Budimir, M. V. ; Simonović, R. M. ; Jovanović, V. M.</creator><creatorcontrib>Petković, B. B. ; Sovilj, S. P. ; Budimir, M. V. ; Simonović, R. M. ; Jovanović, V. M.</creatorcontrib><description>The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10−1–1.0×10−6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10−7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.201000053</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>11-tetraazacyclotetradecane ; Coated glassy carbon rod ; Cu(II) potentiometric sensors ; Ionophore ; N,N′,N″,N′′′‐Tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane ; N′′′-Tetrakis(2-pyridylmethyl)-1 ; Waste waters</subject><ispartof>Electroanalysis (New York, N.Y.), 2010-08, Vol.22 (16), p.1894-1900</ispartof><rights>Copyright © 2010 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3933-787345596b37f05fdbd9a0c2bc2099a18ae30b464de74267023111452d7e5cc83</citedby><cites>FETCH-LOGICAL-c3933-787345596b37f05fdbd9a0c2bc2099a18ae30b464de74267023111452d7e5cc83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Felan.201000053$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.201000053$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids></links><search><creatorcontrib>Petković, B. B.</creatorcontrib><creatorcontrib>Sovilj, S. P.</creatorcontrib><creatorcontrib>Budimir, M. V.</creatorcontrib><creatorcontrib>Simonović, R. M.</creatorcontrib><creatorcontrib>Jovanović, V. M.</creatorcontrib><title>A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10−1–1.0×10−6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10−7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.</description><subject>11-tetraazacyclotetradecane</subject><subject>Coated glassy carbon rod</subject><subject>Cu(II) potentiometric sensors</subject><subject>Ionophore</subject><subject>N,N′,N″,N′′′‐Tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane</subject><subject>N′′′-Tetrakis(2-pyridylmethyl)-1</subject><subject>Waste waters</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNqFkMtKA0EQRQdR8Ll13UuFdOzn9PQyhqjBGMXnsun0VLB1nAndgzqu_A4_Q__IL3FiRNwJRdUtuKcKbpJsU9KlhLA9KGzZZaTVhEi-lKxRySgWlOjlVhNBMOFarSbrMd61Fp0KvZa89VC_ms0g7AyHu2hYlfgCCnC1fwR0VtVQ1r56gDp4hy6gjFVA-zZCjqoSjTvjz9f3efv4VovCl63b3vu4w_CsCT5vipa_bYpdTDuik3UoxfXcYl-sa1xRfS85OFsC8iU6u-6jE9s-fN5MVqa2iLD1MzeSq4PBZf8Ij04Ph_3eCDuuOccqU1xIqdMJV1Mip_kk15Y4NnGMaG1pZoGTiUhFDkqwVBHGKaVCslyBdC7jG0l3cdeFKsYAUzML_sGGxlBi5smaebLmN9kW0AvgyRfQ_OM2g1Fv_JfFC9bHGp5_WRvuTaq4kuZmfGiYusnSYyHNOf8COgyQDQ</recordid><startdate>201008</startdate><enddate>201008</enddate><creator>Petković, B. B.</creator><creator>Sovilj, S. P.</creator><creator>Budimir, M. V.</creator><creator>Simonović, R. M.</creator><creator>Jovanović, V. M.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201008</creationdate><title>A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix</title><author>Petković, B. B. ; Sovilj, S. P. ; Budimir, M. V. ; Simonović, R. M. ; Jovanović, V. M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3933-787345596b37f05fdbd9a0c2bc2099a18ae30b464de74267023111452d7e5cc83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>11-tetraazacyclotetradecane</topic><topic>Coated glassy carbon rod</topic><topic>Cu(II) potentiometric sensors</topic><topic>Ionophore</topic><topic>N,N′,N″,N′′′‐Tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane</topic><topic>N′′′-Tetrakis(2-pyridylmethyl)-1</topic><topic>Waste waters</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Petković, B. B.</creatorcontrib><creatorcontrib>Sovilj, S. P.</creatorcontrib><creatorcontrib>Budimir, M. V.</creatorcontrib><creatorcontrib>Simonović, R. M.</creatorcontrib><creatorcontrib>Jovanović, V. M.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Petković, B. B.</au><au>Sovilj, S. P.</au><au>Budimir, M. V.</au><au>Simonović, R. M.</au><au>Jovanović, V. M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2010-08</date><risdate>2010</risdate><volume>22</volume><issue>16</issue><spage>1894</spage><epage>1900</epage><pages>1894-1900</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The simple PVC‐based membrane containing N,N′,N″,N′′′‐tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane (tpmc) as an ionophore and dibutyl phthalate as a plasticizer, directly coated on a glassy carbon electrode was examined as a new sensor for Cu2+ ions. The potential response was linear within the concentration range of 1.0×10−1–1.0×10−6 M with a Nernstian slope of 28.8 mV/decade and detection limit of 7.0×10−7 M. The electrode was used in aqueous solutions over a wide pH range (1.3–6). The sensor exhibited excellent selectivity for Cu2+ ion over a number of cations and was successfully used in its determination in real samples.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.201000053</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2010-08, Vol.22 (16), p.1894-1900 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_crossref_primary_10_1002_elan_201000053 |
source | Wiley-Blackwell Journals |
subjects | 11-tetraazacyclotetradecane Coated glassy carbon rod Cu(II) potentiometric sensors Ionophore N,N′,N″,N′′′‐Tetrakis(2‐pyridylmethyl)‐1,4,8,11‐tetraazacyclotetradecane N′′′-Tetrakis(2-pyridylmethyl)-1 Waste waters |
title | A Copper(II) Ion-Selective Potentiometric Sensor Based on N,N′,N″,N′′′-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane in PVC Matrix |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-07T16%3A02%3A06IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=A%20Copper(II)%20Ion-Selective%20Potentiometric%20Sensor%20Based%20on%20N,N%E2%80%B2,N%E2%80%B3,N%E2%80%B2%E2%80%B2%E2%80%B2-Tetrakis(2-pyridylmethyl)-1,4,8,11-tetraazacyclotetradecane%20in%20PVC%20Matrix&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Petkovi%C4%87,%20B.%E2%80%85B.&rft.date=2010-08&rft.volume=22&rft.issue=16&rft.spage=1894&rft.epage=1900&rft.pages=1894-1900&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.201000053&rft_dat=%3Cwiley_cross%3EELAN201000053%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |