Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection
The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopam...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 2005-07, Vol.17 (13), p.1153-1159 |
---|---|
Hauptverfasser: | , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 1159 |
---|---|
container_issue | 13 |
container_start_page | 1153 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 17 |
creator | Fischer, David J. Vandaveer IV, Walter R. Grigsby, Ryan J. Lunte, Susan M. |
description | The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopamine (DA), 5‐hydroxyindole‐3‐acetic acid (5‐HIAA), ascorbic acid (AA), and catechol. Initial studies with DA show the response of the PPF electrodes to be linear between 25 and 500 μM (r2=0.999) with a limit of detection (LOD) of 5 μM (S/N=3) and sensitivity of 5.8 pA/μM. Selectivity was further enhanced by employing dual‐electrode detection in the series configuration for detection of species exhibiting chemically reversible redox reactions. |
doi_str_mv | 10.1002/elan.200503239 |
format | Article |
fullrecord | <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_200503239</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_LG644Q4W_S</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3279-6a4e65eb56668db27ebd7007d2c4ee1aa054e6c77e066d85c627b175b2ee05d23</originalsourceid><addsrcrecordid>eNqFkE1PwkAQhjdGExG9et4_UJxu94MeCSCaVMSo4bjZtkO6WthmW4P111tSJd48zWTmfSaTh5DrEEYhALvB0uxGDEBAxKL4hAxCwcKAhxCfdj1wCCCK1Tm5qOs3AIgljwekWrXele0X5nRVuMZ5rG3d0KnxqdvReYlZ412ONd04Tx9s5l1W2Op3URU9QPe2Kejsw5TBEaGTbYXebbHxNqMzbLq5dbtLcrYxZY1XP3VIXm_nL9O7IHlc3E8nSZBFTMWBNBylwFRIKcd5yhSmuQJQOcs4YmgMiC6QKYUgZT4WmWQqDZVIGSKInEVDMurvdi_XtceNrrzdGt_qEPTBlz740kdfHRD3wN6W2P6T1vNksvzLBj3bucPPI2v8u5YqUkKvlwudLCTnT3ytn6NvPhuBPg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Fischer, David J. ; Vandaveer IV, Walter R. ; Grigsby, Ryan J. ; Lunte, Susan M.</creator><creatorcontrib>Fischer, David J. ; Vandaveer IV, Walter R. ; Grigsby, Ryan J. ; Lunte, Susan M.</creatorcontrib><description>The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopamine (DA), 5‐hydroxyindole‐3‐acetic acid (5‐HIAA), ascorbic acid (AA), and catechol. Initial studies with DA show the response of the PPF electrodes to be linear between 25 and 500 μM (r2=0.999) with a limit of detection (LOD) of 5 μM (S/N=3) and sensitivity of 5.8 pA/μM. Selectivity was further enhanced by employing dual‐electrode detection in the series configuration for detection of species exhibiting chemically reversible redox reactions.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.200503239</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Amperometric detection ; Dual-electrode ; Microchip capillary electrophoresis ; Miniaturization ; Pyrolyzed photoresist films</subject><ispartof>Electroanalysis (New York, N.Y.), 2005-07, Vol.17 (13), p.1153-1159</ispartof><rights>Copyright © 2005 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3279-6a4e65eb56668db27ebd7007d2c4ee1aa054e6c77e066d85c627b175b2ee05d23</citedby><cites>FETCH-LOGICAL-c3279-6a4e65eb56668db27ebd7007d2c4ee1aa054e6c77e066d85c627b175b2ee05d23</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.200503239$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45575</link.rule.ids></links><search><creatorcontrib>Fischer, David J.</creatorcontrib><creatorcontrib>Vandaveer IV, Walter R.</creatorcontrib><creatorcontrib>Grigsby, Ryan J.</creatorcontrib><creatorcontrib>Lunte, Susan M.</creatorcontrib><title>Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopamine (DA), 5‐hydroxyindole‐3‐acetic acid (5‐HIAA), ascorbic acid (AA), and catechol. Initial studies with DA show the response of the PPF electrodes to be linear between 25 and 500 μM (r2=0.999) with a limit of detection (LOD) of 5 μM (S/N=3) and sensitivity of 5.8 pA/μM. Selectivity was further enhanced by employing dual‐electrode detection in the series configuration for detection of species exhibiting chemically reversible redox reactions.</description><subject>Amperometric detection</subject><subject>Dual-electrode</subject><subject>Microchip capillary electrophoresis</subject><subject>Miniaturization</subject><subject>Pyrolyzed photoresist films</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkE1PwkAQhjdGExG9et4_UJxu94MeCSCaVMSo4bjZtkO6WthmW4P111tSJd48zWTmfSaTh5DrEEYhALvB0uxGDEBAxKL4hAxCwcKAhxCfdj1wCCCK1Tm5qOs3AIgljwekWrXele0X5nRVuMZ5rG3d0KnxqdvReYlZ412ONd04Tx9s5l1W2Op3URU9QPe2Kejsw5TBEaGTbYXebbHxNqMzbLq5dbtLcrYxZY1XP3VIXm_nL9O7IHlc3E8nSZBFTMWBNBylwFRIKcd5yhSmuQJQOcs4YmgMiC6QKYUgZT4WmWQqDZVIGSKInEVDMurvdi_XtceNrrzdGt_qEPTBlz740kdfHRD3wN6W2P6T1vNksvzLBj3bucPPI2v8u5YqUkKvlwudLCTnT3ytn6NvPhuBPg</recordid><startdate>200507</startdate><enddate>200507</enddate><creator>Fischer, David J.</creator><creator>Vandaveer IV, Walter R.</creator><creator>Grigsby, Ryan J.</creator><creator>Lunte, Susan M.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200507</creationdate><title>Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection</title><author>Fischer, David J. ; Vandaveer IV, Walter R. ; Grigsby, Ryan J. ; Lunte, Susan M.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3279-6a4e65eb56668db27ebd7007d2c4ee1aa054e6c77e066d85c627b175b2ee05d23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Amperometric detection</topic><topic>Dual-electrode</topic><topic>Microchip capillary electrophoresis</topic><topic>Miniaturization</topic><topic>Pyrolyzed photoresist films</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Fischer, David J.</creatorcontrib><creatorcontrib>Vandaveer IV, Walter R.</creatorcontrib><creatorcontrib>Grigsby, Ryan J.</creatorcontrib><creatorcontrib>Lunte, Susan M.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Fischer, David J.</au><au>Vandaveer IV, Walter R.</au><au>Grigsby, Ryan J.</au><au>Lunte, Susan M.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2005-07</date><risdate>2005</risdate><volume>17</volume><issue>13</issue><spage>1153</spage><epage>1159</epage><pages>1153-1159</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The fabrication and evaluation of pyrolyzed photoresist films (PPF) for microchip capillary electrophoresis (CE) with dual‐electrode electrochemical (EC) detection is described. The sensitivity, linearity, and reproducibility were evaluated using catecholamines and related compounds, including dopamine (DA), 5‐hydroxyindole‐3‐acetic acid (5‐HIAA), ascorbic acid (AA), and catechol. Initial studies with DA show the response of the PPF electrodes to be linear between 25 and 500 μM (r2=0.999) with a limit of detection (LOD) of 5 μM (S/N=3) and sensitivity of 5.8 pA/μM. Selectivity was further enhanced by employing dual‐electrode detection in the series configuration for detection of species exhibiting chemically reversible redox reactions.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.200503239</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2005-07, Vol.17 (13), p.1153-1159 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_crossref_primary_10_1002_elan_200503239 |
source | Wiley Online Library Journals Frontfile Complete |
subjects | Amperometric detection Dual-electrode Microchip capillary electrophoresis Miniaturization Pyrolyzed photoresist films |
title | Pyrolyzed Photoresist Carbon Electrodes for Microchip Electrophoresis with Dual-Electrode Amperometric Detection |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-06T19%3A40%3A32IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Pyrolyzed%20Photoresist%20Carbon%20Electrodes%20for%20Microchip%20Electrophoresis%20with%20Dual-Electrode%20Amperometric%20Detection&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Fischer,%20David%E2%80%85J.&rft.date=2005-07&rft.volume=17&rft.issue=13&rft.spage=1153&rft.epage=1159&rft.pages=1153-1159&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.200503239&rft_dat=%3Cistex_cross%3Eark_67375_WNG_LG644Q4W_S%3C/istex_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |