Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays
The use of platinum‐and gold‐ultramicroelectrode arrays for heavy metal analysis is described. The noble metal microelectrodes are structured with standard silicon technologies. The geometry of the electrode array is varied and optimized in regard to the microelectrode characteristic. Mercury film f...
Gespeichert in:
Veröffentlicht in: | Electroanalysis (New York, N.Y.) N.Y.), 1997-02, Vol.9 (2), p.125-129 |
---|---|
Hauptverfasser: | , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 129 |
---|---|
container_issue | 2 |
container_start_page | 125 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 9 |
creator | Uhlig, Albrecht Schnakemberg, Uwe Hintsche, Rainer |
description | The use of platinum‐and gold‐ultramicroelectrode arrays for heavy metal analysis is described. The noble metal microelectrodes are structured with standard silicon technologies. The geometry of the electrode array is varied and optimized in regard to the microelectrode characteristic. Mercury film formation and–dissolution on platinum microelectrode arrays is characterized and compared with iridium electrodes of the same geometry. Gold microelectrode arrays are shown to be useful for mercury detection. The repeated use of the sensors has been studied. Optimizing the electrode gemoetry and the stripping procedure results in detection limits down to the ng/L range. |
doi_str_mv | 10.1002/elan.1140090207 |
format | Article |
fullrecord | <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_1140090207</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_NH4RWWHS_S</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3297-9346d2f9e607f79c5362e109a37e795b0feb6027137168087fa15fe31ffd7e953</originalsourceid><addsrcrecordid>eNqFkMFOwkAQhhujiYieve4LFGa7bZeNJ0KQmhBMROW4WdpZWN22ZLegfXtLMBpPnmYy-b_Jny8IbikMKEA0RKuqAaUxgIAI-FnQo0lEw5iCOO92iCEEJvhlcOX9G3SpNBa94DUzm61ticfKm8YckGxRHVpSYqMsUZWyrTee1BXZWdWYal-G3bUgm9oW4d42TpUmdzVazBtXF0iUc6r118GFVtbjzffsBy_30-dJFs4fZw-T8TzMWSR4KFicFpEWmALXXOQJSyPsCivGkYtkDRrXKUScMk7TEYy4VjTRyKjWBUeRsH4wPP3tOnjvUMudM6VyraQgj1rkUYv81dIRdyfiw1hs_4vL6Xy8-EOHJ9r4Bj9_aOXeZcoZT-RqMZOLLH5arbKlXLIv8_p3qQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays</title><source>Wiley Online Library All Journals</source><creator>Uhlig, Albrecht ; Schnakemberg, Uwe ; Hintsche, Rainer</creator><creatorcontrib>Uhlig, Albrecht ; Schnakemberg, Uwe ; Hintsche, Rainer</creatorcontrib><description>The use of platinum‐and gold‐ultramicroelectrode arrays for heavy metal analysis is described. The noble metal microelectrodes are structured with standard silicon technologies. The geometry of the electrode array is varied and optimized in regard to the microelectrode characteristic. Mercury film formation and–dissolution on platinum microelectrode arrays is characterized and compared with iridium electrodes of the same geometry. Gold microelectrode arrays are shown to be useful for mercury detection. The repeated use of the sensors has been studied. Optimizing the electrode gemoetry and the stripping procedure results in detection limits down to the ng/L range.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.1140090207</identifier><language>eng</language><publisher>Weinheim: VCH Verlagsgesellschaft mbH</publisher><subject>Microelectrode ; Silicon technology ; Stripping analysis</subject><ispartof>Electroanalysis (New York, N.Y.), 1997-02, Vol.9 (2), p.125-129</ispartof><rights>Copyright © 1997 VCH Verlagsgesellschaft mbH</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3297-9346d2f9e607f79c5362e109a37e795b0feb6027137168087fa15fe31ffd7e953</citedby><cites>FETCH-LOGICAL-c3297-9346d2f9e607f79c5362e109a37e795b0feb6027137168087fa15fe31ffd7e953</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Felan.1140090207$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Felan.1140090207$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,776,780,1411,27901,27902,45550,45551</link.rule.ids></links><search><creatorcontrib>Uhlig, Albrecht</creatorcontrib><creatorcontrib>Schnakemberg, Uwe</creatorcontrib><creatorcontrib>Hintsche, Rainer</creatorcontrib><title>Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>The use of platinum‐and gold‐ultramicroelectrode arrays for heavy metal analysis is described. The noble metal microelectrodes are structured with standard silicon technologies. The geometry of the electrode array is varied and optimized in regard to the microelectrode characteristic. Mercury film formation and–dissolution on platinum microelectrode arrays is characterized and compared with iridium electrodes of the same geometry. Gold microelectrode arrays are shown to be useful for mercury detection. The repeated use of the sensors has been studied. Optimizing the electrode gemoetry and the stripping procedure results in detection limits down to the ng/L range.</description><subject>Microelectrode</subject><subject>Silicon technology</subject><subject>Stripping analysis</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1997</creationdate><recordtype>article</recordtype><recordid>eNqFkMFOwkAQhhujiYieve4LFGa7bZeNJ0KQmhBMROW4WdpZWN22ZLegfXtLMBpPnmYy-b_Jny8IbikMKEA0RKuqAaUxgIAI-FnQo0lEw5iCOO92iCEEJvhlcOX9G3SpNBa94DUzm61ticfKm8YckGxRHVpSYqMsUZWyrTee1BXZWdWYal-G3bUgm9oW4d42TpUmdzVazBtXF0iUc6r118GFVtbjzffsBy_30-dJFs4fZw-T8TzMWSR4KFicFpEWmALXXOQJSyPsCivGkYtkDRrXKUScMk7TEYy4VjTRyKjWBUeRsH4wPP3tOnjvUMudM6VyraQgj1rkUYv81dIRdyfiw1hs_4vL6Xy8-EOHJ9r4Bj9_aOXeZcoZT-RqMZOLLH5arbKlXLIv8_p3qQ</recordid><startdate>199702</startdate><enddate>199702</enddate><creator>Uhlig, Albrecht</creator><creator>Schnakemberg, Uwe</creator><creator>Hintsche, Rainer</creator><general>VCH Verlagsgesellschaft mbH</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199702</creationdate><title>Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays</title><author>Uhlig, Albrecht ; Schnakemberg, Uwe ; Hintsche, Rainer</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3297-9346d2f9e607f79c5362e109a37e795b0feb6027137168087fa15fe31ffd7e953</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1997</creationdate><topic>Microelectrode</topic><topic>Silicon technology</topic><topic>Stripping analysis</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Uhlig, Albrecht</creatorcontrib><creatorcontrib>Schnakemberg, Uwe</creatorcontrib><creatorcontrib>Hintsche, Rainer</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Uhlig, Albrecht</au><au>Schnakemberg, Uwe</au><au>Hintsche, Rainer</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>1997-02</date><risdate>1997</risdate><volume>9</volume><issue>2</issue><spage>125</spage><epage>129</epage><pages>125-129</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>The use of platinum‐and gold‐ultramicroelectrode arrays for heavy metal analysis is described. The noble metal microelectrodes are structured with standard silicon technologies. The geometry of the electrode array is varied and optimized in regard to the microelectrode characteristic. Mercury film formation and–dissolution on platinum microelectrode arrays is characterized and compared with iridium electrodes of the same geometry. Gold microelectrode arrays are shown to be useful for mercury detection. The repeated use of the sensors has been studied. Optimizing the electrode gemoetry and the stripping procedure results in detection limits down to the ng/L range.</abstract><cop>Weinheim</cop><pub>VCH Verlagsgesellschaft mbH</pub><doi>10.1002/elan.1140090207</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 1997-02, Vol.9 (2), p.125-129 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_crossref_primary_10_1002_elan_1140090207 |
source | Wiley Online Library All Journals |
subjects | Microelectrode Silicon technology Stripping analysis |
title | Highly sensitive heavy metal analysis on platinum- and gold-ultramicroelectrode arrays |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-11T17%3A12%3A13IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Highly%20sensitive%20heavy%20metal%20analysis%20on%20platinum-%20and%20gold-ultramicroelectrode%20arrays&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Uhlig,%20Albrecht&rft.date=1997-02&rft.volume=9&rft.issue=2&rft.spage=125&rft.epage=129&rft.pages=125-129&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.1140090207&rft_dat=%3Cistex_cross%3Eark_67375_WNG_NH4RWWHS_S%3C/istex_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |