Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude

For the insulation diagnosis of stator windings of generators, sampling surveys are conducted on the coils to estimate the dielectric strength of the stator winding. Previous research has relied on inferring the breakdown voltage of the stator winding from the value 3σ away from the mean value of th...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Electrical engineering in Japan 2025-01
Hauptverfasser: Nakamura, Shin, Kanegami, Masaki, Kuraishi, Takashi, Miyazaki, Satoru
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title Electrical engineering in Japan
container_volume
creator Nakamura, Shin
Kanegami, Masaki
Kuraishi, Takashi
Miyazaki, Satoru
description For the insulation diagnosis of stator windings of generators, sampling surveys are conducted on the coils to estimate the dielectric strength of the stator winding. Previous research has relied on inferring the breakdown voltage of the stator winding from the value 3σ away from the mean value of the breakdown voltage of the coil. However, this conventional method exhibits a significant estimation error when the sample size is small. Therefore, we propose a method for estimating the breakdown voltage of the stator winding based on the maximum value of the partial discharge magnitude and the minimum value of the breakdown voltage of the sample coil. We verify this method by Monte Carlo simulation assuming a sampling survey of coils.
doi_str_mv 10.1002/eej.23489
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1002_eej_23489</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1002_eej_23489</sourcerecordid><originalsourceid>FETCH-LOGICAL-c119t-e337b26e6e80fb5337a405637b66dc8cf70323f5807716011d0f73c4305085793</originalsourceid><addsrcrecordid>eNo9kE1LAzEURYMoWKsL_0G2Lqa-TGaS6VL7pVBRUOtySCcvNXWalCQqbvztTqu4utwD78E9hJwzGDCA_BJxPch5UQ0PSI-VOWSiYOKQ9KDIi0xKAcfkJMY1AEgmqx75HuMHtn67QZeocpouVGu1StY76g2dxGQ3_-06oHrT_tPRhW-TWuEOPiaVfKAv1mnrVnGHZugw7Ok0-A19UCFZ1dKxjc2rCt3ZnVo5m941npIjo9qIZ3_ZJ8_TydPoJpvfz25HV_OsYWyYMuRcLnOBAiswy7JrqoBSdFAI3VSNkcBzbsoKpGQCGNNgJG8KDiVUpRzyPrn4_dsEH2NAU29DNyx81Qzqnbi6E1fvxfEfqEBhYA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Nakamura, Shin ; Kanegami, Masaki ; Kuraishi, Takashi ; Miyazaki, Satoru</creator><creatorcontrib>Nakamura, Shin ; Kanegami, Masaki ; Kuraishi, Takashi ; Miyazaki, Satoru</creatorcontrib><description>For the insulation diagnosis of stator windings of generators, sampling surveys are conducted on the coils to estimate the dielectric strength of the stator winding. Previous research has relied on inferring the breakdown voltage of the stator winding from the value 3σ away from the mean value of the breakdown voltage of the coil. However, this conventional method exhibits a significant estimation error when the sample size is small. Therefore, we propose a method for estimating the breakdown voltage of the stator winding based on the maximum value of the partial discharge magnitude and the minimum value of the breakdown voltage of the sample coil. We verify this method by Monte Carlo simulation assuming a sampling survey of coils.</description><identifier>ISSN: 0424-7760</identifier><identifier>EISSN: 1520-6416</identifier><identifier>DOI: 10.1002/eej.23489</identifier><language>eng</language><ispartof>Electrical engineering in Japan, 2025-01</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c119t-e337b26e6e80fb5337a405637b66dc8cf70323f5807716011d0f73c4305085793</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids></links><search><creatorcontrib>Nakamura, Shin</creatorcontrib><creatorcontrib>Kanegami, Masaki</creatorcontrib><creatorcontrib>Kuraishi, Takashi</creatorcontrib><creatorcontrib>Miyazaki, Satoru</creatorcontrib><title>Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude</title><title>Electrical engineering in Japan</title><description>For the insulation diagnosis of stator windings of generators, sampling surveys are conducted on the coils to estimate the dielectric strength of the stator winding. Previous research has relied on inferring the breakdown voltage of the stator winding from the value 3σ away from the mean value of the breakdown voltage of the coil. However, this conventional method exhibits a significant estimation error when the sample size is small. Therefore, we propose a method for estimating the breakdown voltage of the stator winding based on the maximum value of the partial discharge magnitude and the minimum value of the breakdown voltage of the sample coil. We verify this method by Monte Carlo simulation assuming a sampling survey of coils.</description><issn>0424-7760</issn><issn>1520-6416</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><recordid>eNo9kE1LAzEURYMoWKsL_0G2Lqa-TGaS6VL7pVBRUOtySCcvNXWalCQqbvztTqu4utwD78E9hJwzGDCA_BJxPch5UQ0PSI-VOWSiYOKQ9KDIi0xKAcfkJMY1AEgmqx75HuMHtn67QZeocpouVGu1StY76g2dxGQ3_-06oHrT_tPRhW-TWuEOPiaVfKAv1mnrVnGHZugw7Ok0-A19UCFZ1dKxjc2rCt3ZnVo5m941npIjo9qIZ3_ZJ8_TydPoJpvfz25HV_OsYWyYMuRcLnOBAiswy7JrqoBSdFAI3VSNkcBzbsoKpGQCGNNgJG8KDiVUpRzyPrn4_dsEH2NAU29DNyx81Qzqnbi6E1fvxfEfqEBhYA</recordid><startdate>20250106</startdate><enddate>20250106</enddate><creator>Nakamura, Shin</creator><creator>Kanegami, Masaki</creator><creator>Kuraishi, Takashi</creator><creator>Miyazaki, Satoru</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>20250106</creationdate><title>Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude</title><author>Nakamura, Shin ; Kanegami, Masaki ; Kuraishi, Takashi ; Miyazaki, Satoru</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c119t-e337b26e6e80fb5337a405637b66dc8cf70323f5807716011d0f73c4305085793</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Nakamura, Shin</creatorcontrib><creatorcontrib>Kanegami, Masaki</creatorcontrib><creatorcontrib>Kuraishi, Takashi</creatorcontrib><creatorcontrib>Miyazaki, Satoru</creatorcontrib><collection>CrossRef</collection><jtitle>Electrical engineering in Japan</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Nakamura, Shin</au><au>Kanegami, Masaki</au><au>Kuraishi, Takashi</au><au>Miyazaki, Satoru</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude</atitle><jtitle>Electrical engineering in Japan</jtitle><date>2025-01-06</date><risdate>2025</risdate><issn>0424-7760</issn><eissn>1520-6416</eissn><abstract>For the insulation diagnosis of stator windings of generators, sampling surveys are conducted on the coils to estimate the dielectric strength of the stator winding. Previous research has relied on inferring the breakdown voltage of the stator winding from the value 3σ away from the mean value of the breakdown voltage of the coil. However, this conventional method exhibits a significant estimation error when the sample size is small. Therefore, we propose a method for estimating the breakdown voltage of the stator winding based on the maximum value of the partial discharge magnitude and the minimum value of the breakdown voltage of the sample coil. We verify this method by Monte Carlo simulation assuming a sampling survey of coils.</abstract><doi>10.1002/eej.23489</doi></addata></record>
fulltext fulltext
identifier ISSN: 0424-7760
ispartof Electrical engineering in Japan, 2025-01
issn 0424-7760
1520-6416
language eng
recordid cdi_crossref_primary_10_1002_eej_23489
source Wiley Online Library Journals Frontfile Complete
title Development and Validation of Estimation of Breakdown Voltage of Stator Windings of Generator From Partial Discharge Magnitude
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T17%3A57%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20and%20Validation%20of%20Estimation%20of%20Breakdown%20Voltage%20of%20Stator%20Windings%20of%20Generator%20From%20Partial%20Discharge%20Magnitude&rft.jtitle=Electrical%20engineering%20in%20Japan&rft.au=Nakamura,%20Shin&rft.date=2025-01-06&rft.issn=0424-7760&rft.eissn=1520-6416&rft_id=info:doi/10.1002/eej.23489&rft_dat=%3Ccrossref%3E10_1002_eej_23489%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true