Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen

The minimum reinforcement of reinforced masonry under bending should according to DIN EN 1996‐1‐1:2013‐02 [N 1], Section 8.2.3(1), be not less than ρ min = 0.05 % of the effective masonry cross‐section for building elements, in which the reinforcement makes a contribution to the loadbearing capacity...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Mauerwerk 2019-08, Vol.23 (4), p.209-226
1. Verfasser: Gunkler, Erhard
Format: Artikel
Sprache:ger
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 226
container_issue 4
container_start_page 209
container_title Mauerwerk
container_volume 23
creator Gunkler, Erhard
description The minimum reinforcement of reinforced masonry under bending should according to DIN EN 1996‐1‐1:2013‐02 [N 1], Section 8.2.3(1), be not less than ρ min = 0.05 % of the effective masonry cross‐section for building elements, in which the reinforcement makes a contribution to the loadbearing capacity of the section, with the effective masonry cross‐section being the product of the effective width (b ef ) and the usable height d of the building element. In order to limit cracking and increase the ductility of the element, the reinforcement area should according to [N 1], Section 8.2.3(3), be not less than 0.03 % of the gross cross‐sectional area (of a wall). Other regulations ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) also prescribe minimum reinforcements in order to avoid brittle behaviour of the building element when the first crack forms or to limit cracking. In this specialist article, the figures given in [N 1] for the minimum reinforcement of reinforced masonry beams, like flat lintels or prefabricated lintels, are checked. The work concentrates on avoiding brittle failure when the first crack forms. In addition to geometrical requirements, the amount of minimum reinforcement depends on the tensile strength of the masonry f t,m . Values of ρ min vary considerably depending on the magnitude of the tensile strength of the masonry that can be assumed. For lintels over openings in facing brickwork facades, the height of any capping or soldier courses under the reinforcement layer also has an enlarging influence on the value of ρ min . With regard to future regulations in standards or Allgemeine bauaufsichtliche Zulassungen (national technical approvals), it is recommended not to give lump sum values for ρ min but to undertake a calculation like for reinforced concrete, using the algorithms given in this article. Die Mindestbewehrung biegebeanspruchten bewehrten Mauerwerks sollte nach DIN EN 1996‐1‐1:2013‐02 [N 1], Abschnitt 8.2.3(1), bei Bauteilen, bei denen die Bewehrung einen Beitrag zur Querschnittstragfähigkeit leistet, nicht weniger als ρ min = 0,05 % des wirksamen Mauerwerksquerschnitts betragen. Dabei ist der wirksame Mauerwerksquerschnitt das Produkt aus der effektiven Breite (b ef ) und der Nutzhöhe d des Bauteils. Zur Rissebeschränkung und Erhöhung der Bauteilduktilität sollte der Bewehrungsquerschnitt nach [N 1], Abschnitt 8.2.3(3), nicht weniger als 0,03 % der Bruttoquerschnittsfläche (einer Wand) betragen. Auch andere Regelwerke ([1], [N
doi_str_mv 10.1002/dama.201900009
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1002_dama_201900009</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1002_dama_201900009</sourcerecordid><originalsourceid>FETCH-crossref_primary_10_1002_dama_2019000093</originalsourceid><addsrcrecordid>eNqVjzFuwkAURFcokSAJLfVewM7ftQWijkBpaKIo7WqBb2PWXkf_r4Wgyh1yhRyDzjfJSWIniD7TzGikGekJMVEQKwD9uLWVjTWoOXSaD8RIpcksUqD1zW_WUZLq2VDcMe8BEqXT6UhUq8JvkcMaD7ijxudybUuH3lIociT514curWyDdEBy7GrPgRoXitqjl98fn_KtJt7syvYrR5m1Z5KnxrVnn_Un8gVzLLtr9A_iNrMl4_ji9yJeLl6fnqMN1cyEmXmnorJ0NApMD2V6KHOFSv49-AF0t1tt</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Gunkler, Erhard</creator><creatorcontrib>Gunkler, Erhard</creatorcontrib><description>The minimum reinforcement of reinforced masonry under bending should according to DIN EN 1996‐1‐1:2013‐02 [N 1], Section 8.2.3(1), be not less than ρ min = 0.05 % of the effective masonry cross‐section for building elements, in which the reinforcement makes a contribution to the loadbearing capacity of the section, with the effective masonry cross‐section being the product of the effective width (b ef ) and the usable height d of the building element. In order to limit cracking and increase the ductility of the element, the reinforcement area should according to [N 1], Section 8.2.3(3), be not less than 0.03 % of the gross cross‐sectional area (of a wall). Other regulations ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) also prescribe minimum reinforcements in order to avoid brittle behaviour of the building element when the first crack forms or to limit cracking. In this specialist article, the figures given in [N 1] for the minimum reinforcement of reinforced masonry beams, like flat lintels or prefabricated lintels, are checked. The work concentrates on avoiding brittle failure when the first crack forms. In addition to geometrical requirements, the amount of minimum reinforcement depends on the tensile strength of the masonry f t,m . Values of ρ min vary considerably depending on the magnitude of the tensile strength of the masonry that can be assumed. For lintels over openings in facing brickwork facades, the height of any capping or soldier courses under the reinforcement layer also has an enlarging influence on the value of ρ min . With regard to future regulations in standards or Allgemeine bauaufsichtliche Zulassungen (national technical approvals), it is recommended not to give lump sum values for ρ min but to undertake a calculation like for reinforced concrete, using the algorithms given in this article. Die Mindestbewehrung biegebeanspruchten bewehrten Mauerwerks sollte nach DIN EN 1996‐1‐1:2013‐02 [N 1], Abschnitt 8.2.3(1), bei Bauteilen, bei denen die Bewehrung einen Beitrag zur Querschnittstragfähigkeit leistet, nicht weniger als ρ min = 0,05 % des wirksamen Mauerwerksquerschnitts betragen. Dabei ist der wirksame Mauerwerksquerschnitt das Produkt aus der effektiven Breite (b ef ) und der Nutzhöhe d des Bauteils. Zur Rissebeschränkung und Erhöhung der Bauteilduktilität sollte der Bewehrungsquerschnitt nach [N 1], Abschnitt 8.2.3(3), nicht weniger als 0,03 % der Bruttoquerschnittsfläche (einer Wand) betragen. Auch andere Regelwerke ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) schreiben Mindestbewehrungen vor, um ein sprödes Versagen des Bauteils bei der Bildung des ersten Risses zu vermeiden oder eine Rissbeschränkung zu gewährleisten. In diesem Fachaufsatz werden in [N 1] angegebene Zahlenwerte für die Mindestbewehrung von bewehrten Mauerwerksbalken, wie Flachstürzen oder Fertigteilstürzen, überprüft. Hierbei steht das Kriterium der Vermeidung spröden Versagens bei Erstrissbildung im Fokus der Betrachtungen. Neben Geometrievorgaben hängt die Höhe der Mindestbewehrung von der Zugfestigkeit des Mauerwerks f t,m ab. Je nach der Höhe der anrechenbaren Zugfestigkeit des Mauerwerks variieren die ρ min ‐Werte erheblich. Bei Stürzen über Öffnungen in gemauerten Verblendschalen von Fassaden geht von der Höhe unterhalb der Bewehrungslage sich befindender Roll‐ oder Grenadierschichten ebenfalls ein den ρ min ‐Wert deutlich vergrößernder Einfluss aus. Im Hinblick auf zukünftige Regelungen in Normen oder allgemeinen bauaufsichtlichen Zulassungen (abZ) wird empfohlen, keinen pauschalen Wert für ρ min anzugeben, sondern eine Berechnung wie im Stahlbetonbau mit Hilfe der in diesem Aufsatz angegebenen Algorithmen vorzunehmen.</description><identifier>ISSN: 1432-3427</identifier><identifier>EISSN: 1437-1022</identifier><identifier>DOI: 10.1002/dama.201900009</identifier><language>ger</language><ispartof>Mauerwerk, 2019-08, Vol.23 (4), p.209-226</ispartof><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-crossref_primary_10_1002_dama_2019000093</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Gunkler, Erhard</creatorcontrib><title>Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen</title><title>Mauerwerk</title><description>The minimum reinforcement of reinforced masonry under bending should according to DIN EN 1996‐1‐1:2013‐02 [N 1], Section 8.2.3(1), be not less than ρ min = 0.05 % of the effective masonry cross‐section for building elements, in which the reinforcement makes a contribution to the loadbearing capacity of the section, with the effective masonry cross‐section being the product of the effective width (b ef ) and the usable height d of the building element. In order to limit cracking and increase the ductility of the element, the reinforcement area should according to [N 1], Section 8.2.3(3), be not less than 0.03 % of the gross cross‐sectional area (of a wall). Other regulations ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) also prescribe minimum reinforcements in order to avoid brittle behaviour of the building element when the first crack forms or to limit cracking. In this specialist article, the figures given in [N 1] for the minimum reinforcement of reinforced masonry beams, like flat lintels or prefabricated lintels, are checked. The work concentrates on avoiding brittle failure when the first crack forms. In addition to geometrical requirements, the amount of minimum reinforcement depends on the tensile strength of the masonry f t,m . Values of ρ min vary considerably depending on the magnitude of the tensile strength of the masonry that can be assumed. For lintels over openings in facing brickwork facades, the height of any capping or soldier courses under the reinforcement layer also has an enlarging influence on the value of ρ min . With regard to future regulations in standards or Allgemeine bauaufsichtliche Zulassungen (national technical approvals), it is recommended not to give lump sum values for ρ min but to undertake a calculation like for reinforced concrete, using the algorithms given in this article. Die Mindestbewehrung biegebeanspruchten bewehrten Mauerwerks sollte nach DIN EN 1996‐1‐1:2013‐02 [N 1], Abschnitt 8.2.3(1), bei Bauteilen, bei denen die Bewehrung einen Beitrag zur Querschnittstragfähigkeit leistet, nicht weniger als ρ min = 0,05 % des wirksamen Mauerwerksquerschnitts betragen. Dabei ist der wirksame Mauerwerksquerschnitt das Produkt aus der effektiven Breite (b ef ) und der Nutzhöhe d des Bauteils. Zur Rissebeschränkung und Erhöhung der Bauteilduktilität sollte der Bewehrungsquerschnitt nach [N 1], Abschnitt 8.2.3(3), nicht weniger als 0,03 % der Bruttoquerschnittsfläche (einer Wand) betragen. Auch andere Regelwerke ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) schreiben Mindestbewehrungen vor, um ein sprödes Versagen des Bauteils bei der Bildung des ersten Risses zu vermeiden oder eine Rissbeschränkung zu gewährleisten. In diesem Fachaufsatz werden in [N 1] angegebene Zahlenwerte für die Mindestbewehrung von bewehrten Mauerwerksbalken, wie Flachstürzen oder Fertigteilstürzen, überprüft. Hierbei steht das Kriterium der Vermeidung spröden Versagens bei Erstrissbildung im Fokus der Betrachtungen. Neben Geometrievorgaben hängt die Höhe der Mindestbewehrung von der Zugfestigkeit des Mauerwerks f t,m ab. Je nach der Höhe der anrechenbaren Zugfestigkeit des Mauerwerks variieren die ρ min ‐Werte erheblich. Bei Stürzen über Öffnungen in gemauerten Verblendschalen von Fassaden geht von der Höhe unterhalb der Bewehrungslage sich befindender Roll‐ oder Grenadierschichten ebenfalls ein den ρ min ‐Wert deutlich vergrößernder Einfluss aus. Im Hinblick auf zukünftige Regelungen in Normen oder allgemeinen bauaufsichtlichen Zulassungen (abZ) wird empfohlen, keinen pauschalen Wert für ρ min anzugeben, sondern eine Berechnung wie im Stahlbetonbau mit Hilfe der in diesem Aufsatz angegebenen Algorithmen vorzunehmen.</description><issn>1432-3427</issn><issn>1437-1022</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNqVjzFuwkAURFcokSAJLfVewM7ftQWijkBpaKIo7WqBb2PWXkf_r4Wgyh1yhRyDzjfJSWIniD7TzGikGekJMVEQKwD9uLWVjTWoOXSaD8RIpcksUqD1zW_WUZLq2VDcMe8BEqXT6UhUq8JvkcMaD7ijxudybUuH3lIociT514curWyDdEBy7GrPgRoXitqjl98fn_KtJt7syvYrR5m1Z5KnxrVnn_Un8gVzLLtr9A_iNrMl4_ji9yJeLl6fnqMN1cyEmXmnorJ0NApMD2V6KHOFSv49-AF0t1tt</recordid><startdate>201908</startdate><enddate>201908</enddate><creator>Gunkler, Erhard</creator><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201908</creationdate><title>Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen</title><author>Gunkler, Erhard</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-crossref_primary_10_1002_dama_2019000093</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>ger</language><creationdate>2019</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Gunkler, Erhard</creatorcontrib><collection>CrossRef</collection><jtitle>Mauerwerk</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gunkler, Erhard</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen</atitle><jtitle>Mauerwerk</jtitle><date>2019-08</date><risdate>2019</risdate><volume>23</volume><issue>4</issue><spage>209</spage><epage>226</epage><pages>209-226</pages><issn>1432-3427</issn><eissn>1437-1022</eissn><abstract>The minimum reinforcement of reinforced masonry under bending should according to DIN EN 1996‐1‐1:2013‐02 [N 1], Section 8.2.3(1), be not less than ρ min = 0.05 % of the effective masonry cross‐section for building elements, in which the reinforcement makes a contribution to the loadbearing capacity of the section, with the effective masonry cross‐section being the product of the effective width (b ef ) and the usable height d of the building element. In order to limit cracking and increase the ductility of the element, the reinforcement area should according to [N 1], Section 8.2.3(3), be not less than 0.03 % of the gross cross‐sectional area (of a wall). Other regulations ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) also prescribe minimum reinforcements in order to avoid brittle behaviour of the building element when the first crack forms or to limit cracking. In this specialist article, the figures given in [N 1] for the minimum reinforcement of reinforced masonry beams, like flat lintels or prefabricated lintels, are checked. The work concentrates on avoiding brittle failure when the first crack forms. In addition to geometrical requirements, the amount of minimum reinforcement depends on the tensile strength of the masonry f t,m . Values of ρ min vary considerably depending on the magnitude of the tensile strength of the masonry that can be assumed. For lintels over openings in facing brickwork facades, the height of any capping or soldier courses under the reinforcement layer also has an enlarging influence on the value of ρ min . With regard to future regulations in standards or Allgemeine bauaufsichtliche Zulassungen (national technical approvals), it is recommended not to give lump sum values for ρ min but to undertake a calculation like for reinforced concrete, using the algorithms given in this article. Die Mindestbewehrung biegebeanspruchten bewehrten Mauerwerks sollte nach DIN EN 1996‐1‐1:2013‐02 [N 1], Abschnitt 8.2.3(1), bei Bauteilen, bei denen die Bewehrung einen Beitrag zur Querschnittstragfähigkeit leistet, nicht weniger als ρ min = 0,05 % des wirksamen Mauerwerksquerschnitts betragen. Dabei ist der wirksame Mauerwerksquerschnitt das Produkt aus der effektiven Breite (b ef ) und der Nutzhöhe d des Bauteils. Zur Rissebeschränkung und Erhöhung der Bauteilduktilität sollte der Bewehrungsquerschnitt nach [N 1], Abschnitt 8.2.3(3), nicht weniger als 0,03 % der Bruttoquerschnittsfläche (einer Wand) betragen. Auch andere Regelwerke ([1], [N 2], [N 3], [N 4], [N 5], [N 6], [N 7]) schreiben Mindestbewehrungen vor, um ein sprödes Versagen des Bauteils bei der Bildung des ersten Risses zu vermeiden oder eine Rissbeschränkung zu gewährleisten. In diesem Fachaufsatz werden in [N 1] angegebene Zahlenwerte für die Mindestbewehrung von bewehrten Mauerwerksbalken, wie Flachstürzen oder Fertigteilstürzen, überprüft. Hierbei steht das Kriterium der Vermeidung spröden Versagens bei Erstrissbildung im Fokus der Betrachtungen. Neben Geometrievorgaben hängt die Höhe der Mindestbewehrung von der Zugfestigkeit des Mauerwerks f t,m ab. Je nach der Höhe der anrechenbaren Zugfestigkeit des Mauerwerks variieren die ρ min ‐Werte erheblich. Bei Stürzen über Öffnungen in gemauerten Verblendschalen von Fassaden geht von der Höhe unterhalb der Bewehrungslage sich befindender Roll‐ oder Grenadierschichten ebenfalls ein den ρ min ‐Wert deutlich vergrößernder Einfluss aus. Im Hinblick auf zukünftige Regelungen in Normen oder allgemeinen bauaufsichtlichen Zulassungen (abZ) wird empfohlen, keinen pauschalen Wert für ρ min anzugeben, sondern eine Berechnung wie im Stahlbetonbau mit Hilfe der in diesem Aufsatz angegebenen Algorithmen vorzunehmen.</abstract><doi>10.1002/dama.201900009</doi></addata></record>
fulltext fulltext
identifier ISSN: 1432-3427
ispartof Mauerwerk, 2019-08, Vol.23 (4), p.209-226
issn 1432-3427
1437-1022
language ger
recordid cdi_crossref_primary_10_1002_dama_201900009
source Wiley Online Library Journals Frontfile Complete
title Mindestbewehrung balkenartiger bewehrter Mauerwerkskonstruktionen – Vorschläge für zukünftige Regelungen
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T20%3A02%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Mindestbewehrung%20balkenartiger%20bewehrter%20Mauerwerkskonstruktionen%20%E2%80%93%20Vorschl%C3%A4ge%20f%C3%BCr%20zuk%C3%BCnftige%20Regelungen&rft.jtitle=Mauerwerk&rft.au=Gunkler,%20Erhard&rft.date=2019-08&rft.volume=23&rft.issue=4&rft.spage=209&rft.epage=226&rft.pages=209-226&rft.issn=1432-3427&rft.eissn=1437-1022&rft_id=info:doi/10.1002/dama.201900009&rft_dat=%3Ccrossref%3E10_1002_dama_201900009%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true