Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography

The ability to create uniform liquor flow in the counter‐current zones of a continuous digester was studied in the laboratory using a 40L model digester equipped with an eight‐plane electrical resistance tomography (ERT) sensor array. Conductively tagged fluid flows were visualized moving through a...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Canadian journal of chemical engineering 2005-02, Vol.83 (1), p.42-47
Hauptverfasser: Vlaev, Dimiter S., Bennington, Chad P. J.
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 47
container_issue 1
container_start_page 42
container_title Canadian journal of chemical engineering
container_volume 83
creator Vlaev, Dimiter S.
Bennington, Chad P. J.
description The ability to create uniform liquor flow in the counter‐current zones of a continuous digester was studied in the laboratory using a 40L model digester equipped with an eight‐plane electrical resistance tomography (ERT) sensor array. Conductively tagged fluid flows were visualized moving through a stationary bed of uncooked wood chips for a range of process flow conditions. Simulations using scaled axial (upflow) and downcomer‐screen (radial) flows were used to model the counter‐current zones in two industrial digesters. These were compared with flow patterns obtained by varying the ratio of upflow to downcomer‐screen flow over a wider range. The optimal flow ratios and fluxes are discussed with regard to radial and vertical zone uniformity. La capacité à créer un écoulement de liqueur uniforme dans les zones à contre‐courant d'un digesteur continu a été étudiée en laboratoire à l'aide d'un digesteur modèle de 40 L muni d'une grille de capteurs de tomographie à résistance électrique (ERT) sur huit plans. Des écoulements de fluides marqués de façon conductrice ont été visualisés lors de leur déplacement dans un lit stationnaire de copeaux de bois non cuits pour une gamme de conditions d'écoulement de procédé. On a utilisé des simulations utilisant des écoulements axiaux (ascendants) et des écoulements déversoir‐tamis (radiaux) mis à l'échelle afin de modéliser les zones à contre‐courant dans deux digesteurs industriels. Ces données ont été comparées à des profils d'écoulement obtenus en variant le rapport entre l'écoulement ascendant et l'écoulement déversoir‐tamis sur une large gamme. Les débits et flux optimums sont examinés pour ce qui est de l'uniformité des zones radiale et verticale.
doi_str_mv 10.1002/cjce.5450830108
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_cjce_5450830108</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>CJCE5450830108</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3988-5da162b9b359fe8c97c90e215b9717dbf896e3391978ff35881c1697ad8e95353</originalsourceid><addsrcrecordid>eNqFkM9LwzAUx4MoOKdnr7l47JY0S5vgSbof_tgUxobiJaTp65bZrSOpzP33dlQcnjw9Hnw_3_f4IHRNSYcSEnbNykCH9zgRjFAiTlCLSiYDQuXbKWoRQkTQI6x3ji68X9VrSHq0habDotzh-cbmpVvbao_tBms8KTMocN8uwFfg8AS0_3SQ4Z2tlnhQgKmcNbrAU_DWV3pjAM_KdblwervcX6KzXBcern5mG82Hg1lyH4xfRg_J3TgwTAoR8EzTKExlyrjMQRgZG0kgpDyVMY2zNBcyAsYklbHIc8aFoIZGMtaZAMkZZ23UbXqNK713kKuts2vt9ooSdVCiDkrUUUlN3DTEVvv6_dzVn1t_xCJBIkLjOnfb5Ha2gP1_tSp5TAZ_rgQNXauBr19auw8VxSzm6vV5pJ5Ef_g-jRIVsm-dvoHT</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography</title><source>Wiley Online Library Journals Frontfile Complete</source><creator>Vlaev, Dimiter S. ; Bennington, Chad P. J.</creator><creatorcontrib>Vlaev, Dimiter S. ; Bennington, Chad P. J.</creatorcontrib><description>The ability to create uniform liquor flow in the counter‐current zones of a continuous digester was studied in the laboratory using a 40L model digester equipped with an eight‐plane electrical resistance tomography (ERT) sensor array. Conductively tagged fluid flows were visualized moving through a stationary bed of uncooked wood chips for a range of process flow conditions. Simulations using scaled axial (upflow) and downcomer‐screen (radial) flows were used to model the counter‐current zones in two industrial digesters. These were compared with flow patterns obtained by varying the ratio of upflow to downcomer‐screen flow over a wider range. The optimal flow ratios and fluxes are discussed with regard to radial and vertical zone uniformity. La capacité à créer un écoulement de liqueur uniforme dans les zones à contre‐courant d'un digesteur continu a été étudiée en laboratoire à l'aide d'un digesteur modèle de 40 L muni d'une grille de capteurs de tomographie à résistance électrique (ERT) sur huit plans. Des écoulements de fluides marqués de façon conductrice ont été visualisés lors de leur déplacement dans un lit stationnaire de copeaux de bois non cuits pour une gamme de conditions d'écoulement de procédé. On a utilisé des simulations utilisant des écoulements axiaux (ascendants) et des écoulements déversoir‐tamis (radiaux) mis à l'échelle afin de modéliser les zones à contre‐courant dans deux digesteurs industriels. Ces données ont été comparées à des profils d'écoulement obtenus en variant le rapport entre l'écoulement ascendant et l'écoulement déversoir‐tamis sur une large gamme. Les débits et flux optimums sont examinés pour ce qui est de l'uniformité des zones radiale et verticale.</description><identifier>ISSN: 0008-4034</identifier><identifier>EISSN: 1939-019X</identifier><identifier>DOI: 10.1002/cjce.5450830108</identifier><identifier>CODEN: CJCEA7</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Applied sciences ; Chemical engineering ; chip digester ; electrical resistance tomography ; Exact sciences and technology ; Hydrodynamics of contact apparatus ; kraft pulping ; liquor flows</subject><ispartof>Canadian journal of chemical engineering, 2005-02, Vol.83 (1), p.42-47</ispartof><rights>Copyright © 2005 Canadian Society for Chemical Engineering</rights><rights>2005 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3988-5da162b9b359fe8c97c90e215b9717dbf896e3391978ff35881c1697ad8e95353</citedby><cites>FETCH-LOGICAL-c3988-5da162b9b359fe8c97c90e215b9717dbf896e3391978ff35881c1697ad8e95353</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fcjce.5450830108$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fcjce.5450830108$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>309,310,314,777,781,786,787,1412,23911,23912,25121,27905,27906,45555,45556</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=16806017$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Vlaev, Dimiter S.</creatorcontrib><creatorcontrib>Bennington, Chad P. J.</creatorcontrib><title>Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography</title><title>Canadian journal of chemical engineering</title><addtitle>Can. J. Chem. Eng</addtitle><description>The ability to create uniform liquor flow in the counter‐current zones of a continuous digester was studied in the laboratory using a 40L model digester equipped with an eight‐plane electrical resistance tomography (ERT) sensor array. Conductively tagged fluid flows were visualized moving through a stationary bed of uncooked wood chips for a range of process flow conditions. Simulations using scaled axial (upflow) and downcomer‐screen (radial) flows were used to model the counter‐current zones in two industrial digesters. These were compared with flow patterns obtained by varying the ratio of upflow to downcomer‐screen flow over a wider range. The optimal flow ratios and fluxes are discussed with regard to radial and vertical zone uniformity. La capacité à créer un écoulement de liqueur uniforme dans les zones à contre‐courant d'un digesteur continu a été étudiée en laboratoire à l'aide d'un digesteur modèle de 40 L muni d'une grille de capteurs de tomographie à résistance électrique (ERT) sur huit plans. Des écoulements de fluides marqués de façon conductrice ont été visualisés lors de leur déplacement dans un lit stationnaire de copeaux de bois non cuits pour une gamme de conditions d'écoulement de procédé. On a utilisé des simulations utilisant des écoulements axiaux (ascendants) et des écoulements déversoir‐tamis (radiaux) mis à l'échelle afin de modéliser les zones à contre‐courant dans deux digesteurs industriels. Ces données ont été comparées à des profils d'écoulement obtenus en variant le rapport entre l'écoulement ascendant et l'écoulement déversoir‐tamis sur une large gamme. Les débits et flux optimums sont examinés pour ce qui est de l'uniformité des zones radiale et verticale.</description><subject>Applied sciences</subject><subject>Chemical engineering</subject><subject>chip digester</subject><subject>electrical resistance tomography</subject><subject>Exact sciences and technology</subject><subject>Hydrodynamics of contact apparatus</subject><subject>kraft pulping</subject><subject>liquor flows</subject><issn>0008-4034</issn><issn>1939-019X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkM9LwzAUx4MoOKdnr7l47JY0S5vgSbof_tgUxobiJaTp65bZrSOpzP33dlQcnjw9Hnw_3_f4IHRNSYcSEnbNykCH9zgRjFAiTlCLSiYDQuXbKWoRQkTQI6x3ji68X9VrSHq0habDotzh-cbmpVvbao_tBms8KTMocN8uwFfg8AS0_3SQ4Z2tlnhQgKmcNbrAU_DWV3pjAM_KdblwervcX6KzXBcern5mG82Hg1lyH4xfRg_J3TgwTAoR8EzTKExlyrjMQRgZG0kgpDyVMY2zNBcyAsYklbHIc8aFoIZGMtaZAMkZZ23UbXqNK713kKuts2vt9ooSdVCiDkrUUUlN3DTEVvv6_dzVn1t_xCJBIkLjOnfb5Ha2gP1_tSp5TAZ_rgQNXauBr19auw8VxSzm6vV5pJ5Ef_g-jRIVsm-dvoHT</recordid><startdate>200502</startdate><enddate>200502</enddate><creator>Vlaev, Dimiter S.</creator><creator>Bennington, Chad P. J.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200502</creationdate><title>Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography</title><author>Vlaev, Dimiter S. ; Bennington, Chad P. J.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3988-5da162b9b359fe8c97c90e215b9717dbf896e3391978ff35881c1697ad8e95353</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Applied sciences</topic><topic>Chemical engineering</topic><topic>chip digester</topic><topic>electrical resistance tomography</topic><topic>Exact sciences and technology</topic><topic>Hydrodynamics of contact apparatus</topic><topic>kraft pulping</topic><topic>liquor flows</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Vlaev, Dimiter S.</creatorcontrib><creatorcontrib>Bennington, Chad P. J.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>Canadian journal of chemical engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Vlaev, Dimiter S.</au><au>Bennington, Chad P. J.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography</atitle><jtitle>Canadian journal of chemical engineering</jtitle><addtitle>Can. J. Chem. Eng</addtitle><date>2005-02</date><risdate>2005</risdate><volume>83</volume><issue>1</issue><spage>42</spage><epage>47</epage><pages>42-47</pages><issn>0008-4034</issn><eissn>1939-019X</eissn><coden>CJCEA7</coden><abstract>The ability to create uniform liquor flow in the counter‐current zones of a continuous digester was studied in the laboratory using a 40L model digester equipped with an eight‐plane electrical resistance tomography (ERT) sensor array. Conductively tagged fluid flows were visualized moving through a stationary bed of uncooked wood chips for a range of process flow conditions. Simulations using scaled axial (upflow) and downcomer‐screen (radial) flows were used to model the counter‐current zones in two industrial digesters. These were compared with flow patterns obtained by varying the ratio of upflow to downcomer‐screen flow over a wider range. The optimal flow ratios and fluxes are discussed with regard to radial and vertical zone uniformity. La capacité à créer un écoulement de liqueur uniforme dans les zones à contre‐courant d'un digesteur continu a été étudiée en laboratoire à l'aide d'un digesteur modèle de 40 L muni d'une grille de capteurs de tomographie à résistance électrique (ERT) sur huit plans. Des écoulements de fluides marqués de façon conductrice ont été visualisés lors de leur déplacement dans un lit stationnaire de copeaux de bois non cuits pour une gamme de conditions d'écoulement de procédé. On a utilisé des simulations utilisant des écoulements axiaux (ascendants) et des écoulements déversoir‐tamis (radiaux) mis à l'échelle afin de modéliser les zones à contre‐courant dans deux digesteurs industriels. Ces données ont été comparées à des profils d'écoulement obtenus en variant le rapport entre l'écoulement ascendant et l'écoulement déversoir‐tamis sur une large gamme. Les débits et flux optimums sont examinés pour ce qui est de l'uniformité des zones radiale et verticale.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/cjce.5450830108</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0008-4034
ispartof Canadian journal of chemical engineering, 2005-02, Vol.83 (1), p.42-47
issn 0008-4034
1939-019X
language eng
recordid cdi_crossref_primary_10_1002_cjce_5450830108
source Wiley Online Library Journals Frontfile Complete
subjects Applied sciences
Chemical engineering
chip digester
electrical resistance tomography
Exact sciences and technology
Hydrodynamics of contact apparatus
kraft pulping
liquor flows
title Flow Uniformity in a Model Digester Measured with Electrical Resistance Tomography
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T17%3A50%3A11IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Flow%20Uniformity%20in%20a%20Model%20Digester%20Measured%20with%20Electrical%20Resistance%20Tomography&rft.jtitle=Canadian%20journal%20of%20chemical%20engineering&rft.au=Vlaev,%20Dimiter%20S.&rft.date=2005-02&rft.volume=83&rft.issue=1&rft.spage=42&rft.epage=47&rft.pages=42-47&rft.issn=0008-4034&rft.eissn=1939-019X&rft.coden=CJCEA7&rft_id=info:doi/10.1002/cjce.5450830108&rft_dat=%3Cwiley_cross%3ECJCE5450830108%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true