Influence of water saturation on the compressive strength of concrete under high strain rates

In this study, the influence of different water saturation achieved by different storage conditions on the static and dynamic compressive strength of three different concretes were investigated. The specimens were first dried then water‐saturated and tested both under static and impact loading. The...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Civil engineering design 2023-09, Vol.5 (3-4), p.39-45
Hauptverfasser: Mosig, Oliver, Beckmann, Birgit, Curbach, Manfred
Format: Artikel
Sprache:eng
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 45
container_issue 3-4
container_start_page 39
container_title Civil engineering design
container_volume 5
creator Mosig, Oliver
Beckmann, Birgit
Curbach, Manfred
description In this study, the influence of different water saturation achieved by different storage conditions on the static and dynamic compressive strength of three different concretes were investigated. The specimens were first dried then water‐saturated and tested both under static and impact loading. The impact tests were carried out in a split Hopkinson bar. Depending on the concrete strength class, increases in the compressive strength of 200%–300% at strain rates in the range of 90–160 1/s were observed. Compared to storage under ambient conditions, the compressive strength decreases as a result of drying due to microcrack formation. Furthermore, the concretes compressive strengths of water‐saturated specimens decrease compared to dry specimens. This decrease was observed under both static and impact loading and is independent of the strain rate. The failure of the dry specimens was more explosive with an increased number of cracks compared to water‐saturated specimens.
doi_str_mv 10.1002/cend.202200015
format Article
fullrecord <record><control><sourceid>crossref</sourceid><recordid>TN_cdi_crossref_primary_10_1002_cend_202200015</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1002_cend_202200015</sourcerecordid><originalsourceid>FETCH-LOGICAL-c795-40dc2e5873258ca38ddb89d398b67afd1ac072b491f1079dee00f2d7017fcd213</originalsourceid><addsrcrecordid>eNpNkE9LxDAUxIMouKx79Zwv0PqSNJv2KIt_Fha87MGLhDR52VZ20yVJFb-9LYoIA29g5s3hR8gtg5IB8DuLwZUcOAcAJi_Igq-5LECJ18t__pqsUnqfKkKwSgi5IG_b4I8jBot08PTTZIw0mTxGk_sh0Em5Q2qH0zliSv0H0pQjhkPu5r4dgo2YkY7BTY9df-jm3PSBTgOYbsiVN8eEq9-7JPvHh_3mudi9PG0397vCqkYWFTjLUdZKcFlbI2rn2rpxoqnbtTLeMWNB8bZqmGegGocI4LlTwJS3jjOxJOXPrI1DShG9Psf-ZOKXZqBnPHrGo__wiG-b1FpT</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Influence of water saturation on the compressive strength of concrete under high strain rates</title><source>Access via Wiley Online Library</source><creator>Mosig, Oliver ; Beckmann, Birgit ; Curbach, Manfred</creator><creatorcontrib>Mosig, Oliver ; Beckmann, Birgit ; Curbach, Manfred</creatorcontrib><description>In this study, the influence of different water saturation achieved by different storage conditions on the static and dynamic compressive strength of three different concretes were investigated. The specimens were first dried then water‐saturated and tested both under static and impact loading. The impact tests were carried out in a split Hopkinson bar. Depending on the concrete strength class, increases in the compressive strength of 200%–300% at strain rates in the range of 90–160 1/s were observed. Compared to storage under ambient conditions, the compressive strength decreases as a result of drying due to microcrack formation. Furthermore, the concretes compressive strengths of water‐saturated specimens decrease compared to dry specimens. This decrease was observed under both static and impact loading and is independent of the strain rate. The failure of the dry specimens was more explosive with an increased number of cracks compared to water‐saturated specimens.</description><identifier>ISSN: 2625-073X</identifier><identifier>EISSN: 2625-073X</identifier><identifier>DOI: 10.1002/cend.202200015</identifier><language>eng</language><ispartof>Civil engineering design, 2023-09, Vol.5 (3-4), p.39-45</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c795-40dc2e5873258ca38ddb89d398b67afd1ac072b491f1079dee00f2d7017fcd213</cites><orcidid>0000-0001-6666-5388</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Mosig, Oliver</creatorcontrib><creatorcontrib>Beckmann, Birgit</creatorcontrib><creatorcontrib>Curbach, Manfred</creatorcontrib><title>Influence of water saturation on the compressive strength of concrete under high strain rates</title><title>Civil engineering design</title><description>In this study, the influence of different water saturation achieved by different storage conditions on the static and dynamic compressive strength of three different concretes were investigated. The specimens were first dried then water‐saturated and tested both under static and impact loading. The impact tests were carried out in a split Hopkinson bar. Depending on the concrete strength class, increases in the compressive strength of 200%–300% at strain rates in the range of 90–160 1/s were observed. Compared to storage under ambient conditions, the compressive strength decreases as a result of drying due to microcrack formation. Furthermore, the concretes compressive strengths of water‐saturated specimens decrease compared to dry specimens. This decrease was observed under both static and impact loading and is independent of the strain rate. The failure of the dry specimens was more explosive with an increased number of cracks compared to water‐saturated specimens.</description><issn>2625-073X</issn><issn>2625-073X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNpNkE9LxDAUxIMouKx79Zwv0PqSNJv2KIt_Fha87MGLhDR52VZ20yVJFb-9LYoIA29g5s3hR8gtg5IB8DuLwZUcOAcAJi_Igq-5LECJ18t__pqsUnqfKkKwSgi5IG_b4I8jBot08PTTZIw0mTxGk_sh0Em5Q2qH0zliSv0H0pQjhkPu5r4dgo2YkY7BTY9df-jm3PSBTgOYbsiVN8eEq9-7JPvHh_3mudi9PG0397vCqkYWFTjLUdZKcFlbI2rn2rpxoqnbtTLeMWNB8bZqmGegGocI4LlTwJS3jjOxJOXPrI1DShG9Psf-ZOKXZqBnPHrGo__wiG-b1FpT</recordid><startdate>202309</startdate><enddate>202309</enddate><creator>Mosig, Oliver</creator><creator>Beckmann, Birgit</creator><creator>Curbach, Manfred</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-6666-5388</orcidid></search><sort><creationdate>202309</creationdate><title>Influence of water saturation on the compressive strength of concrete under high strain rates</title><author>Mosig, Oliver ; Beckmann, Birgit ; Curbach, Manfred</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c795-40dc2e5873258ca38ddb89d398b67afd1ac072b491f1079dee00f2d7017fcd213</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Mosig, Oliver</creatorcontrib><creatorcontrib>Beckmann, Birgit</creatorcontrib><creatorcontrib>Curbach, Manfred</creatorcontrib><collection>CrossRef</collection><jtitle>Civil engineering design</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Mosig, Oliver</au><au>Beckmann, Birgit</au><au>Curbach, Manfred</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of water saturation on the compressive strength of concrete under high strain rates</atitle><jtitle>Civil engineering design</jtitle><date>2023-09</date><risdate>2023</risdate><volume>5</volume><issue>3-4</issue><spage>39</spage><epage>45</epage><pages>39-45</pages><issn>2625-073X</issn><eissn>2625-073X</eissn><abstract>In this study, the influence of different water saturation achieved by different storage conditions on the static and dynamic compressive strength of three different concretes were investigated. The specimens were first dried then water‐saturated and tested both under static and impact loading. The impact tests were carried out in a split Hopkinson bar. Depending on the concrete strength class, increases in the compressive strength of 200%–300% at strain rates in the range of 90–160 1/s were observed. Compared to storage under ambient conditions, the compressive strength decreases as a result of drying due to microcrack formation. Furthermore, the concretes compressive strengths of water‐saturated specimens decrease compared to dry specimens. This decrease was observed under both static and impact loading and is independent of the strain rate. The failure of the dry specimens was more explosive with an increased number of cracks compared to water‐saturated specimens.</abstract><doi>10.1002/cend.202200015</doi><tpages>7</tpages><orcidid>https://orcid.org/0000-0001-6666-5388</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2625-073X
ispartof Civil engineering design, 2023-09, Vol.5 (3-4), p.39-45
issn 2625-073X
2625-073X
language eng
recordid cdi_crossref_primary_10_1002_cend_202200015
source Access via Wiley Online Library
title Influence of water saturation on the compressive strength of concrete under high strain rates
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-22T13%3A20%3A47IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20water%20saturation%20on%20the%20compressive%20strength%20of%20concrete%20under%20high%20strain%20rates&rft.jtitle=Civil%20engineering%20design&rft.au=Mosig,%20Oliver&rft.date=2023-09&rft.volume=5&rft.issue=3-4&rft.spage=39&rft.epage=45&rft.pages=39-45&rft.issn=2625-073X&rft.eissn=2625-073X&rft_id=info:doi/10.1002/cend.202200015&rft_dat=%3Ccrossref%3E10_1002_cend_202200015%3C/crossref%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true