Chemometric methods for process monitoring and high-performance controller design

A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimens...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:AIChE journal 1992-10, Vol.38 (10), p.1593-1608
Hauptverfasser: Kaspar, Michael H., Ray, W. Harmon
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 1608
container_issue 10
container_start_page 1593
container_title AIChE journal
container_volume 38
creator Kaspar, Michael H.
Ray, W. Harmon
description A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimension than the original data set. Because most of what is eliminated is the collinearity of the original variables and the noise, the bulk of the information contained in the original data set is retained. The resulting low dimensional representation of the data set has been shown to be of great utility for process analysis and monitoring, as well as in selecting variables for control. These types of models can also be used directly in control system design. One way of approaching this is to use the loading matrices as compensators on the plant. Some advantages of using this approach as part of the overall control system design include automatic decoupling and efficient loop pairing, as well as natural handling of nonsquare systems and poorly conditioned systems.
doi_str_mv 10.1002/aic.690381010
format Article
fullrecord <record><control><sourceid>istex_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_aic_690381010</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ark_67375_WNG_3TX2LKWT_D</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3860-98ecffbb6f0610a081c7808123be2dd62cd237746351128c464303fbdcd7c5ca3</originalsourceid><addsrcrecordid>eNp9kM9LwzAUx4MoOKdH7zl47cyPNmmPo-ocDkWYzFtI02SNtk1JCrr_3sjG8OTlPd7j8_2-xxeAa4xmGCFyK62asQLRHCOMTsAEZylPsgJlp2CCEMJJXOBzcBHCR5wIz8kEvJaN7lynR28VjK1xdYDGeTh4p3QIsHO9HZ23_RbKvoaN3TbJoH1EOtkrDZXrR-_aVntY62C3_SU4M7IN-urQp-Dt4X5dPiarl8WynK8SRXOGkiLXypiqYgYxjCTKseJ5rIRWmtQ1I6omlPOU0QxjkquUpRRRU9Wq5ipTkk5BsvdV3oXgtRGDt530O4GR-M1DxDzEMY_I3-z5QQYlW-Pj-zYcRSnNeFqQiPE99mVbvfvfU8yX5d8Dh4dsGPX3USn9p2Cc8kxsnheCrt_J6mmzFnf0BwWngHA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Chemometric methods for process monitoring and high-performance controller design</title><source>Access via Wiley Online Library</source><creator>Kaspar, Michael H. ; Ray, W. Harmon</creator><creatorcontrib>Kaspar, Michael H. ; Ray, W. Harmon</creatorcontrib><description>A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimension than the original data set. Because most of what is eliminated is the collinearity of the original variables and the noise, the bulk of the information contained in the original data set is retained. The resulting low dimensional representation of the data set has been shown to be of great utility for process analysis and monitoring, as well as in selecting variables for control. These types of models can also be used directly in control system design. One way of approaching this is to use the loading matrices as compensators on the plant. Some advantages of using this approach as part of the overall control system design include automatic decoupling and efficient loop pairing, as well as natural handling of nonsquare systems and poorly conditioned systems.</description><identifier>ISSN: 0001-1541</identifier><identifier>EISSN: 1547-5905</identifier><identifier>DOI: 10.1002/aic.690381010</identifier><identifier>CODEN: AICEAC</identifier><language>eng</language><publisher>New York: American Institute of Chemical Engineers</publisher><subject>Applications of mathematics to chemical engineering. Modeling. Simulation. Optimization ; Applied sciences ; Chemical engineering ; Exact sciences and technology</subject><ispartof>AIChE journal, 1992-10, Vol.38 (10), p.1593-1608</ispartof><rights>Copyright © 1992 American Institute of Chemical Engineers</rights><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3860-98ecffbb6f0610a081c7808123be2dd62cd237746351128c464303fbdcd7c5ca3</citedby><cites>FETCH-LOGICAL-c3860-98ecffbb6f0610a081c7808123be2dd62cd237746351128c464303fbdcd7c5ca3</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Faic.690381010$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Faic.690381010$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4357492$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Kaspar, Michael H.</creatorcontrib><creatorcontrib>Ray, W. Harmon</creatorcontrib><title>Chemometric methods for process monitoring and high-performance controller design</title><title>AIChE journal</title><addtitle>AIChE J</addtitle><description>A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimension than the original data set. Because most of what is eliminated is the collinearity of the original variables and the noise, the bulk of the information contained in the original data set is retained. The resulting low dimensional representation of the data set has been shown to be of great utility for process analysis and monitoring, as well as in selecting variables for control. These types of models can also be used directly in control system design. One way of approaching this is to use the loading matrices as compensators on the plant. Some advantages of using this approach as part of the overall control system design include automatic decoupling and efficient loop pairing, as well as natural handling of nonsquare systems and poorly conditioned systems.</description><subject>Applications of mathematics to chemical engineering. Modeling. Simulation. Optimization</subject><subject>Applied sciences</subject><subject>Chemical engineering</subject><subject>Exact sciences and technology</subject><issn>0001-1541</issn><issn>1547-5905</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1992</creationdate><recordtype>article</recordtype><recordid>eNp9kM9LwzAUx4MoOKdH7zl47cyPNmmPo-ocDkWYzFtI02SNtk1JCrr_3sjG8OTlPd7j8_2-xxeAa4xmGCFyK62asQLRHCOMTsAEZylPsgJlp2CCEMJJXOBzcBHCR5wIz8kEvJaN7lynR28VjK1xdYDGeTh4p3QIsHO9HZ23_RbKvoaN3TbJoH1EOtkrDZXrR-_aVntY62C3_SU4M7IN-urQp-Dt4X5dPiarl8WynK8SRXOGkiLXypiqYgYxjCTKseJ5rIRWmtQ1I6omlPOU0QxjkquUpRRRU9Wq5ipTkk5BsvdV3oXgtRGDt530O4GR-M1DxDzEMY_I3-z5QQYlW-Pj-zYcRSnNeFqQiPE99mVbvfvfU8yX5d8Dh4dsGPX3USn9p2Cc8kxsnheCrt_J6mmzFnf0BwWngHA</recordid><startdate>199210</startdate><enddate>199210</enddate><creator>Kaspar, Michael H.</creator><creator>Ray, W. Harmon</creator><general>American Institute of Chemical Engineers</general><general>Wiley Subscription Services</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>199210</creationdate><title>Chemometric methods for process monitoring and high-performance controller design</title><author>Kaspar, Michael H. ; Ray, W. Harmon</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3860-98ecffbb6f0610a081c7808123be2dd62cd237746351128c464303fbdcd7c5ca3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1992</creationdate><topic>Applications of mathematics to chemical engineering. Modeling. Simulation. Optimization</topic><topic>Applied sciences</topic><topic>Chemical engineering</topic><topic>Exact sciences and technology</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kaspar, Michael H.</creatorcontrib><creatorcontrib>Ray, W. Harmon</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>AIChE journal</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kaspar, Michael H.</au><au>Ray, W. Harmon</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Chemometric methods for process monitoring and high-performance controller design</atitle><jtitle>AIChE journal</jtitle><addtitle>AIChE J</addtitle><date>1992-10</date><risdate>1992</risdate><volume>38</volume><issue>10</issue><spage>1593</spage><epage>1608</epage><pages>1593-1608</pages><issn>0001-1541</issn><eissn>1547-5905</eissn><coden>AICEAC</coden><abstract>A huge amount of data is collected by computer monitoring systems in the chemical process industry. Such tools as principal component analysis and partial least squares have been shown to be very effective in compressing this large volume of noisy correlated data into a subspace of much lower dimension than the original data set. Because most of what is eliminated is the collinearity of the original variables and the noise, the bulk of the information contained in the original data set is retained. The resulting low dimensional representation of the data set has been shown to be of great utility for process analysis and monitoring, as well as in selecting variables for control. These types of models can also be used directly in control system design. One way of approaching this is to use the loading matrices as compensators on the plant. Some advantages of using this approach as part of the overall control system design include automatic decoupling and efficient loop pairing, as well as natural handling of nonsquare systems and poorly conditioned systems.</abstract><cop>New York</cop><pub>American Institute of Chemical Engineers</pub><doi>10.1002/aic.690381010</doi><tpages>16</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0001-1541
ispartof AIChE journal, 1992-10, Vol.38 (10), p.1593-1608
issn 0001-1541
1547-5905
language eng
recordid cdi_crossref_primary_10_1002_aic_690381010
source Access via Wiley Online Library
subjects Applications of mathematics to chemical engineering. Modeling. Simulation. Optimization
Applied sciences
Chemical engineering
Exact sciences and technology
title Chemometric methods for process monitoring and high-performance controller design
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-19T07%3A31%3A28IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-istex_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Chemometric%20methods%20for%20process%20monitoring%20and%20high-performance%20controller%20design&rft.jtitle=AIChE%20journal&rft.au=Kaspar,%20Michael%20H.&rft.date=1992-10&rft.volume=38&rft.issue=10&rft.spage=1593&rft.epage=1608&rft.pages=1593-1608&rft.issn=0001-1541&rft.eissn=1547-5905&rft.coden=AICEAC&rft_id=info:doi/10.1002/aic.690381010&rft_dat=%3Cistex_cross%3Eark_67375_WNG_3TX2LKWT_D%3C/istex_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true