High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate

A thermocouple is the most widely used electrical component for cost‐effective measurement of temperature in both academia and industry. However, its low sensitivity with typically tens of microvolts per Kelvin needs to be improved to obtain precise measurements. Introduced here is an ionic thermoco...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advanced electronic materials 2022-05, Vol.8 (5), p.n/a
Hauptverfasser: Jeon, Jei Gyeong, Kim, Hyeong Jun, Shin, Gilyong, Han, Yusu, Kim, Ju Hyeon, Lee, Ju Hwan, Lee, Junho, Lim, Hyeoncheol, Ha, Seulki, Bae, Minwoo, Yoon, Sang‐Hee, Kang, Tae June
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 5
container_start_page
container_title Advanced electronic materials
container_volume 8
creator Jeon, Jei Gyeong
Kim, Hyeong Jun
Shin, Gilyong
Han, Yusu
Kim, Ju Hyeon
Lee, Ju Hwan
Lee, Junho
Lim, Hyeoncheol
Ha, Seulki
Bae, Minwoo
Yoon, Sang‐Hee
Kang, Tae June
description A thermocouple is the most widely used electrical component for cost‐effective measurement of temperature in both academia and industry. However, its low sensitivity with typically tens of microvolts per Kelvin needs to be improved to obtain precise measurements. Introduced here is an ionic thermocouple to provide the level of accuracy required of temperature measurements in medicine, precision agriculture, smart buildings, and industrial processes. Ionic conductors are utilized in place of the electrical conductors typically used in the conventional thermocouples (TCs). The ionic thermocouples (i‐TCs) are demonstrated with redox reactions of 10 × 10−3 m potassium ferri/ferrocyanide and 0.7 m iron(II/III) perchlorate, which are electrolytes used as p‐type and an n‐type elements, respectively. The voltage output of the i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature. The i‐TC can easily be miniaturized as demonstrated for the in situ temperature measurement of the fluid flowing in the channel of a microfluidic device. A flexible and stretchable i‐TC device is also demonstrated to stably operate up to a tensile strain of 23% with no noticeable degradation in performance. Ionic thermocouples (i‐TCs) are fabricated using potassium ferri/ferrocyanide and iron perchlorate. The voltage output of this i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature.
doi_str_mv 10.1002/aelm.202100693
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_aelm_202100693</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>AELM202100693</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2893-2fa7a23dad932ccf69f3fe7f628440cf64eec7d84984bcd324c6651bd81e966a3</originalsourceid><addsrcrecordid>eNqFkM1qAjEURkNpoWLddp0XGM2fmclSRKtgqQuF7oaY3GjKzEQSpbjrI_QZ-ySOWNruurn3fnDPtzgIPVLSp4SwgYaq7jPC2iAVv0EdRpXKqCSvt3_ue9RL6Y0QQnPJxZB30Hbmt7uvj89lBOOTDw2eh8YbvNpBrIMJx30FCU_1JnqjD2DxOvlmi5fhoFPyxxpPIUY_uMxgTrrxFrBuLJ7HtmoJ0eyqEFvwAd05XSXofe8uWk8nq_EsW7w8zcejRWZYoXjGnM4141ZbxZkxTirHHeROskII0mYBYHJbCFWIjbGcCSPlkG5sQUFJqXkX9a-9JoaUIrhyH32t46mkpLyYKi-myh9TLaCuwLuv4PTPdzmaLJ5_2TOWZ3Bg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate</title><source>Wiley Online Library All Journals</source><creator>Jeon, Jei Gyeong ; Kim, Hyeong Jun ; Shin, Gilyong ; Han, Yusu ; Kim, Ju Hyeon ; Lee, Ju Hwan ; Lee, Junho ; Lim, Hyeoncheol ; Ha, Seulki ; Bae, Minwoo ; Yoon, Sang‐Hee ; Kang, Tae June</creator><creatorcontrib>Jeon, Jei Gyeong ; Kim, Hyeong Jun ; Shin, Gilyong ; Han, Yusu ; Kim, Ju Hyeon ; Lee, Ju Hwan ; Lee, Junho ; Lim, Hyeoncheol ; Ha, Seulki ; Bae, Minwoo ; Yoon, Sang‐Hee ; Kang, Tae June</creatorcontrib><description>A thermocouple is the most widely used electrical component for cost‐effective measurement of temperature in both academia and industry. However, its low sensitivity with typically tens of microvolts per Kelvin needs to be improved to obtain precise measurements. Introduced here is an ionic thermocouple to provide the level of accuracy required of temperature measurements in medicine, precision agriculture, smart buildings, and industrial processes. Ionic conductors are utilized in place of the electrical conductors typically used in the conventional thermocouples (TCs). The ionic thermocouples (i‐TCs) are demonstrated with redox reactions of 10 × 10−3 m potassium ferri/ferrocyanide and 0.7 m iron(II/III) perchlorate, which are electrolytes used as p‐type and an n‐type elements, respectively. The voltage output of the i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature. The i‐TC can easily be miniaturized as demonstrated for the in situ temperature measurement of the fluid flowing in the channel of a microfluidic device. A flexible and stretchable i‐TC device is also demonstrated to stably operate up to a tensile strain of 23% with no noticeable degradation in performance. Ionic thermocouples (i‐TCs) are fabricated using potassium ferri/ferrocyanide and iron perchlorate. The voltage output of this i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature.</description><identifier>ISSN: 2199-160X</identifier><identifier>EISSN: 2199-160X</identifier><identifier>DOI: 10.1002/aelm.202100693</identifier><language>eng</language><subject>ferri/ferrocyanide ; ionic Seebeck ; iron(II/III) perchlorate ; thermal electrochemical ; thermocouple</subject><ispartof>Advanced electronic materials, 2022-05, Vol.8 (5), p.n/a</ispartof><rights>2022 Wiley‐VCH GmbH</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c2893-2fa7a23dad932ccf69f3fe7f628440cf64eec7d84984bcd324c6651bd81e966a3</citedby><cites>FETCH-LOGICAL-c2893-2fa7a23dad932ccf69f3fe7f628440cf64eec7d84984bcd324c6651bd81e966a3</cites><orcidid>0000-0002-2787-482X</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Faelm.202100693$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Faelm.202100693$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>315,781,785,1418,27929,27930,45579,45580</link.rule.ids></links><search><creatorcontrib>Jeon, Jei Gyeong</creatorcontrib><creatorcontrib>Kim, Hyeong Jun</creatorcontrib><creatorcontrib>Shin, Gilyong</creatorcontrib><creatorcontrib>Han, Yusu</creatorcontrib><creatorcontrib>Kim, Ju Hyeon</creatorcontrib><creatorcontrib>Lee, Ju Hwan</creatorcontrib><creatorcontrib>Lee, Junho</creatorcontrib><creatorcontrib>Lim, Hyeoncheol</creatorcontrib><creatorcontrib>Ha, Seulki</creatorcontrib><creatorcontrib>Bae, Minwoo</creatorcontrib><creatorcontrib>Yoon, Sang‐Hee</creatorcontrib><creatorcontrib>Kang, Tae June</creatorcontrib><title>High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate</title><title>Advanced electronic materials</title><description>A thermocouple is the most widely used electrical component for cost‐effective measurement of temperature in both academia and industry. However, its low sensitivity with typically tens of microvolts per Kelvin needs to be improved to obtain precise measurements. Introduced here is an ionic thermocouple to provide the level of accuracy required of temperature measurements in medicine, precision agriculture, smart buildings, and industrial processes. Ionic conductors are utilized in place of the electrical conductors typically used in the conventional thermocouples (TCs). The ionic thermocouples (i‐TCs) are demonstrated with redox reactions of 10 × 10−3 m potassium ferri/ferrocyanide and 0.7 m iron(II/III) perchlorate, which are electrolytes used as p‐type and an n‐type elements, respectively. The voltage output of the i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature. The i‐TC can easily be miniaturized as demonstrated for the in situ temperature measurement of the fluid flowing in the channel of a microfluidic device. A flexible and stretchable i‐TC device is also demonstrated to stably operate up to a tensile strain of 23% with no noticeable degradation in performance. Ionic thermocouples (i‐TCs) are fabricated using potassium ferri/ferrocyanide and iron perchlorate. The voltage output of this i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature.</description><subject>ferri/ferrocyanide</subject><subject>ionic Seebeck</subject><subject>iron(II/III) perchlorate</subject><subject>thermal electrochemical</subject><subject>thermocouple</subject><issn>2199-160X</issn><issn>2199-160X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2022</creationdate><recordtype>article</recordtype><recordid>eNqFkM1qAjEURkNpoWLddp0XGM2fmclSRKtgqQuF7oaY3GjKzEQSpbjrI_QZ-ySOWNruurn3fnDPtzgIPVLSp4SwgYaq7jPC2iAVv0EdRpXKqCSvt3_ue9RL6Y0QQnPJxZB30Hbmt7uvj89lBOOTDw2eh8YbvNpBrIMJx30FCU_1JnqjD2DxOvlmi5fhoFPyxxpPIUY_uMxgTrrxFrBuLJ7HtmoJ0eyqEFvwAd05XSXofe8uWk8nq_EsW7w8zcejRWZYoXjGnM4141ZbxZkxTirHHeROskII0mYBYHJbCFWIjbGcCSPlkG5sQUFJqXkX9a-9JoaUIrhyH32t46mkpLyYKi-myh9TLaCuwLuv4PTPdzmaLJ5_2TOWZ3Bg</recordid><startdate>202205</startdate><enddate>202205</enddate><creator>Jeon, Jei Gyeong</creator><creator>Kim, Hyeong Jun</creator><creator>Shin, Gilyong</creator><creator>Han, Yusu</creator><creator>Kim, Ju Hyeon</creator><creator>Lee, Ju Hwan</creator><creator>Lee, Junho</creator><creator>Lim, Hyeoncheol</creator><creator>Ha, Seulki</creator><creator>Bae, Minwoo</creator><creator>Yoon, Sang‐Hee</creator><creator>Kang, Tae June</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-2787-482X</orcidid></search><sort><creationdate>202205</creationdate><title>High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate</title><author>Jeon, Jei Gyeong ; Kim, Hyeong Jun ; Shin, Gilyong ; Han, Yusu ; Kim, Ju Hyeon ; Lee, Ju Hwan ; Lee, Junho ; Lim, Hyeoncheol ; Ha, Seulki ; Bae, Minwoo ; Yoon, Sang‐Hee ; Kang, Tae June</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2893-2fa7a23dad932ccf69f3fe7f628440cf64eec7d84984bcd324c6651bd81e966a3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2022</creationdate><topic>ferri/ferrocyanide</topic><topic>ionic Seebeck</topic><topic>iron(II/III) perchlorate</topic><topic>thermal electrochemical</topic><topic>thermocouple</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Jeon, Jei Gyeong</creatorcontrib><creatorcontrib>Kim, Hyeong Jun</creatorcontrib><creatorcontrib>Shin, Gilyong</creatorcontrib><creatorcontrib>Han, Yusu</creatorcontrib><creatorcontrib>Kim, Ju Hyeon</creatorcontrib><creatorcontrib>Lee, Ju Hwan</creatorcontrib><creatorcontrib>Lee, Junho</creatorcontrib><creatorcontrib>Lim, Hyeoncheol</creatorcontrib><creatorcontrib>Ha, Seulki</creatorcontrib><creatorcontrib>Bae, Minwoo</creatorcontrib><creatorcontrib>Yoon, Sang‐Hee</creatorcontrib><creatorcontrib>Kang, Tae June</creatorcontrib><collection>CrossRef</collection><jtitle>Advanced electronic materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Jeon, Jei Gyeong</au><au>Kim, Hyeong Jun</au><au>Shin, Gilyong</au><au>Han, Yusu</au><au>Kim, Ju Hyeon</au><au>Lee, Ju Hwan</au><au>Lee, Junho</au><au>Lim, Hyeoncheol</au><au>Ha, Seulki</au><au>Bae, Minwoo</au><au>Yoon, Sang‐Hee</au><au>Kang, Tae June</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate</atitle><jtitle>Advanced electronic materials</jtitle><date>2022-05</date><risdate>2022</risdate><volume>8</volume><issue>5</issue><epage>n/a</epage><issn>2199-160X</issn><eissn>2199-160X</eissn><abstract>A thermocouple is the most widely used electrical component for cost‐effective measurement of temperature in both academia and industry. However, its low sensitivity with typically tens of microvolts per Kelvin needs to be improved to obtain precise measurements. Introduced here is an ionic thermocouple to provide the level of accuracy required of temperature measurements in medicine, precision agriculture, smart buildings, and industrial processes. Ionic conductors are utilized in place of the electrical conductors typically used in the conventional thermocouples (TCs). The ionic thermocouples (i‐TCs) are demonstrated with redox reactions of 10 × 10−3 m potassium ferri/ferrocyanide and 0.7 m iron(II/III) perchlorate, which are electrolytes used as p‐type and an n‐type elements, respectively. The voltage output of the i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature. The i‐TC can easily be miniaturized as demonstrated for the in situ temperature measurement of the fluid flowing in the channel of a microfluidic device. A flexible and stretchable i‐TC device is also demonstrated to stably operate up to a tensile strain of 23% with no noticeable degradation in performance. Ionic thermocouples (i‐TCs) are fabricated using potassium ferri/ferrocyanide and iron perchlorate. The voltage output of this i‐TC that is generated by a change in temperature is approximately two orders of magnitude larger than that of the conventional TC, providing almost two more significant figures in measured temperature.</abstract><doi>10.1002/aelm.202100693</doi><tpages>8</tpages><orcidid>https://orcid.org/0000-0002-2787-482X</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2199-160X
ispartof Advanced electronic materials, 2022-05, Vol.8 (5), p.n/a
issn 2199-160X
2199-160X
language eng
recordid cdi_crossref_primary_10_1002_aelm_202100693
source Wiley Online Library All Journals
subjects ferri/ferrocyanide
ionic Seebeck
iron(II/III) perchlorate
thermal electrochemical
thermocouple
title High‐Precision Ionic Thermocouples Fabricated Using Potassium Ferri/Ferrocyanide and Iron Perchlorate
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-15T06%3A40%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=High%E2%80%90Precision%20Ionic%20Thermocouples%20Fabricated%20Using%20Potassium%20Ferri/Ferrocyanide%20and%20Iron%20Perchlorate&rft.jtitle=Advanced%20electronic%20materials&rft.au=Jeon,%20Jei%20Gyeong&rft.date=2022-05&rft.volume=8&rft.issue=5&rft.epage=n/a&rft.issn=2199-160X&rft.eissn=2199-160X&rft_id=info:doi/10.1002/aelm.202100693&rft_dat=%3Cwiley_cross%3EAELM202100693%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true