Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications
A portable, battery‐powered, multi‐purpose readout system for combined optical and thermal measurements is presented. The system is modular with four independent input channels for different measurement schemes, allowing simultaneous multi‐parameter measurements to detect analytes of interest. Combi...
Gespeichert in:
Veröffentlicht in: | Advanced Sensor Research 2025-01, Vol.4 (1), p.n/a |
---|---|
Hauptverfasser: | , , , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | n/a |
---|---|
container_issue | 1 |
container_start_page | |
container_title | Advanced Sensor Research |
container_volume | 4 |
creator | Khan, Dibyendu Wijakmatee, Thossaporn Sriram, Aniruddha Nikookhesal, Aidin Weinhold, Elmar Shimoyama, Yusuke Pachauri, Vivek Ingebrandt, Sven |
description | A portable, battery‐powered, multi‐purpose readout system for combined optical and thermal measurements is presented. The system is modular with four independent input channels for different measurement schemes, allowing simultaneous multi‐parameter measurements to detect analytes of interest. Combined optical and thermal readout for spectroscopy is implemented by installing two different analog front‐end modules in the four input channels equipped with a micro spectrometer and a high‐resolution temperature sensor, respectively. The readout system is utilized to measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. Gold nanoparticles are modified with Guanine‐rich DNA sequences to perform Förster Resonance Energy Transfer (FRET) measurements. Elongation of DNA sequences at higher temperatures resulted in stronger fluorescence signals, accurately recorded by the portable system. The precision electronic components are chosen for a precise, battery‐powered operation. The size of this versatile, compact, and portable instrument is only 15.6 × 10.6 cm2. An interactive graphical‐user‐interface developed for this system supports point‐of‐care usage. The measurements carried out with the portable system showed a very close match with a commercial set‐up, with deviations less than 1 nm in the optical spectra and less than 0.5 °C in temperature.
A portable, battery‐powered, multi‐purpose readout system is developed and used for combined optical and thermal measurements. The system can measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. The measurements with the portable readout system demonstrate a very close match with an industrial measurement set‐up. |
doi_str_mv | 10.1002/adsr.202400105 |
format | Article |
fullrecord | <record><control><sourceid>wiley_doaj_</sourceid><recordid>TN_cdi_crossref_primary_10_1002_adsr_202400105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><doaj_id>oai_doaj_org_article_cc073a61f92c4b09ba306e7e0f2abb17</doaj_id><sourcerecordid>ADSR12333</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2763-d2afb659ba2908535cc0980eb6621e44f471c077d9c04dfc340a6763e5910f5e3</originalsourceid><addsrcrecordid>eNqFkM1OAjEQxxujiQS5et4XAKcfu6VHgl8kEAnowVMz221NyUJJd4nh5iP4jD6JRQzxZg_tZDq_3yR_Qq4pDCgAu8GqiQMGTABQyM9Ih8mc9imj6vxPfUl6TbOCBAwV5YJ1yOssVLsaYzbb1a3_-vicY8S1baM3GW6qbB5ii2Vts4XFKuzabLlvWrvOXIjpz2_ahASXrjFGm42229obbH3YNFfkwmHd2N7v2yUv93fP48f-9OlhMh5N-4bJgvcrhq4sclUiUzDMeW4MqCHYsigYtUI4IakBKStlQFTOcAFYJNDmioLLLe-SydFbBVzpbfRrjHsd0OufRohvGmPrTW11UkuOBXWKGVFC2smhsNKCY1iWVCbX4OgyMTRNtO7ko6APOetDzvqUcwLyI_Dua7v_Z1qPbpcLyng63-3og7w</addsrcrecordid><sourcetype>Open Website</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications</title><source>DOAJ Directory of Open Access Journals</source><source>Wiley-Blackwell Open Access Titles</source><source>Alma/SFX Local Collection</source><creator>Khan, Dibyendu ; Wijakmatee, Thossaporn ; Sriram, Aniruddha ; Nikookhesal, Aidin ; Weinhold, Elmar ; Shimoyama, Yusuke ; Pachauri, Vivek ; Ingebrandt, Sven</creator><creatorcontrib>Khan, Dibyendu ; Wijakmatee, Thossaporn ; Sriram, Aniruddha ; Nikookhesal, Aidin ; Weinhold, Elmar ; Shimoyama, Yusuke ; Pachauri, Vivek ; Ingebrandt, Sven</creatorcontrib><description>A portable, battery‐powered, multi‐purpose readout system for combined optical and thermal measurements is presented. The system is modular with four independent input channels for different measurement schemes, allowing simultaneous multi‐parameter measurements to detect analytes of interest. Combined optical and thermal readout for spectroscopy is implemented by installing two different analog front‐end modules in the four input channels equipped with a micro spectrometer and a high‐resolution temperature sensor, respectively. The readout system is utilized to measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. Gold nanoparticles are modified with Guanine‐rich DNA sequences to perform Förster Resonance Energy Transfer (FRET) measurements. Elongation of DNA sequences at higher temperatures resulted in stronger fluorescence signals, accurately recorded by the portable system. The precision electronic components are chosen for a precise, battery‐powered operation. The size of this versatile, compact, and portable instrument is only 15.6 × 10.6 cm2. An interactive graphical‐user‐interface developed for this system supports point‐of‐care usage. The measurements carried out with the portable system showed a very close match with a commercial set‐up, with deviations less than 1 nm in the optical spectra and less than 0.5 °C in temperature.
A portable, battery‐powered, multi‐purpose readout system is developed and used for combined optical and thermal measurements. The system can measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. The measurements with the portable readout system demonstrate a very close match with an industrial measurement set‐up.</description><identifier>ISSN: 2751-1219</identifier><identifier>EISSN: 2751-1219</identifier><identifier>DOI: 10.1002/adsr.202400105</identifier><language>eng</language><publisher>Wiley-VCH</publisher><subject>DNA ; fluorescence spectroscopy ; FRET ; gold nanoparticles ; optical spectroscopy ; point‐of‐care ; portable readout system</subject><ispartof>Advanced Sensor Research, 2025-01, Vol.4 (1), p.n/a</ispartof><rights>2024 The Author(s). Advanced Sensor Research published by Wiley‐VCH GmbH</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2763-d2afb659ba2908535cc0980eb6621e44f471c077d9c04dfc340a6763e5910f5e3</cites><orcidid>0000-0002-6481-2257 ; 0000-0002-0405-2727 ; 0000-0002-9094-849X ; 0000-0003-3275-2429 ; 0000-0001-6979-3510</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fadsr.202400105$$EPDF$$P50$$Gwiley$$Hfree_for_read</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fadsr.202400105$$EHTML$$P50$$Gwiley$$Hfree_for_read</linktohtml><link.rule.ids>314,776,780,860,2095,11542,27903,27904,46031,46455</link.rule.ids></links><search><creatorcontrib>Khan, Dibyendu</creatorcontrib><creatorcontrib>Wijakmatee, Thossaporn</creatorcontrib><creatorcontrib>Sriram, Aniruddha</creatorcontrib><creatorcontrib>Nikookhesal, Aidin</creatorcontrib><creatorcontrib>Weinhold, Elmar</creatorcontrib><creatorcontrib>Shimoyama, Yusuke</creatorcontrib><creatorcontrib>Pachauri, Vivek</creatorcontrib><creatorcontrib>Ingebrandt, Sven</creatorcontrib><title>Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications</title><title>Advanced Sensor Research</title><description>A portable, battery‐powered, multi‐purpose readout system for combined optical and thermal measurements is presented. The system is modular with four independent input channels for different measurement schemes, allowing simultaneous multi‐parameter measurements to detect analytes of interest. Combined optical and thermal readout for spectroscopy is implemented by installing two different analog front‐end modules in the four input channels equipped with a micro spectrometer and a high‐resolution temperature sensor, respectively. The readout system is utilized to measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. Gold nanoparticles are modified with Guanine‐rich DNA sequences to perform Förster Resonance Energy Transfer (FRET) measurements. Elongation of DNA sequences at higher temperatures resulted in stronger fluorescence signals, accurately recorded by the portable system. The precision electronic components are chosen for a precise, battery‐powered operation. The size of this versatile, compact, and portable instrument is only 15.6 × 10.6 cm2. An interactive graphical‐user‐interface developed for this system supports point‐of‐care usage. The measurements carried out with the portable system showed a very close match with a commercial set‐up, with deviations less than 1 nm in the optical spectra and less than 0.5 °C in temperature.
A portable, battery‐powered, multi‐purpose readout system is developed and used for combined optical and thermal measurements. The system can measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. The measurements with the portable readout system demonstrate a very close match with an industrial measurement set‐up.</description><subject>DNA</subject><subject>fluorescence spectroscopy</subject><subject>FRET</subject><subject>gold nanoparticles</subject><subject>optical spectroscopy</subject><subject>point‐of‐care</subject><subject>portable readout system</subject><issn>2751-1219</issn><issn>2751-1219</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><sourceid>24P</sourceid><sourceid>WIN</sourceid><sourceid>DOA</sourceid><recordid>eNqFkM1OAjEQxxujiQS5et4XAKcfu6VHgl8kEAnowVMz221NyUJJd4nh5iP4jD6JRQzxZg_tZDq_3yR_Qq4pDCgAu8GqiQMGTABQyM9Ih8mc9imj6vxPfUl6TbOCBAwV5YJ1yOssVLsaYzbb1a3_-vicY8S1baM3GW6qbB5ii2Vts4XFKuzabLlvWrvOXIjpz2_ahASXrjFGm42229obbH3YNFfkwmHd2N7v2yUv93fP48f-9OlhMh5N-4bJgvcrhq4sclUiUzDMeW4MqCHYsigYtUI4IakBKStlQFTOcAFYJNDmioLLLe-SydFbBVzpbfRrjHsd0OufRohvGmPrTW11UkuOBXWKGVFC2smhsNKCY1iWVCbX4OgyMTRNtO7ko6APOetDzvqUcwLyI_Dua7v_Z1qPbpcLyng63-3og7w</recordid><startdate>202501</startdate><enddate>202501</enddate><creator>Khan, Dibyendu</creator><creator>Wijakmatee, Thossaporn</creator><creator>Sriram, Aniruddha</creator><creator>Nikookhesal, Aidin</creator><creator>Weinhold, Elmar</creator><creator>Shimoyama, Yusuke</creator><creator>Pachauri, Vivek</creator><creator>Ingebrandt, Sven</creator><general>Wiley-VCH</general><scope>24P</scope><scope>WIN</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>DOA</scope><orcidid>https://orcid.org/0000-0002-6481-2257</orcidid><orcidid>https://orcid.org/0000-0002-0405-2727</orcidid><orcidid>https://orcid.org/0000-0002-9094-849X</orcidid><orcidid>https://orcid.org/0000-0003-3275-2429</orcidid><orcidid>https://orcid.org/0000-0001-6979-3510</orcidid></search><sort><creationdate>202501</creationdate><title>Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications</title><author>Khan, Dibyendu ; Wijakmatee, Thossaporn ; Sriram, Aniruddha ; Nikookhesal, Aidin ; Weinhold, Elmar ; Shimoyama, Yusuke ; Pachauri, Vivek ; Ingebrandt, Sven</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2763-d2afb659ba2908535cc0980eb6621e44f471c077d9c04dfc340a6763e5910f5e3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>DNA</topic><topic>fluorescence spectroscopy</topic><topic>FRET</topic><topic>gold nanoparticles</topic><topic>optical spectroscopy</topic><topic>point‐of‐care</topic><topic>portable readout system</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Khan, Dibyendu</creatorcontrib><creatorcontrib>Wijakmatee, Thossaporn</creatorcontrib><creatorcontrib>Sriram, Aniruddha</creatorcontrib><creatorcontrib>Nikookhesal, Aidin</creatorcontrib><creatorcontrib>Weinhold, Elmar</creatorcontrib><creatorcontrib>Shimoyama, Yusuke</creatorcontrib><creatorcontrib>Pachauri, Vivek</creatorcontrib><creatorcontrib>Ingebrandt, Sven</creatorcontrib><collection>Wiley-Blackwell Open Access Titles</collection><collection>Wiley Free Content</collection><collection>CrossRef</collection><collection>DOAJ Directory of Open Access Journals</collection><jtitle>Advanced Sensor Research</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Khan, Dibyendu</au><au>Wijakmatee, Thossaporn</au><au>Sriram, Aniruddha</au><au>Nikookhesal, Aidin</au><au>Weinhold, Elmar</au><au>Shimoyama, Yusuke</au><au>Pachauri, Vivek</au><au>Ingebrandt, Sven</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications</atitle><jtitle>Advanced Sensor Research</jtitle><date>2025-01</date><risdate>2025</risdate><volume>4</volume><issue>1</issue><epage>n/a</epage><issn>2751-1219</issn><eissn>2751-1219</eissn><abstract>A portable, battery‐powered, multi‐purpose readout system for combined optical and thermal measurements is presented. The system is modular with four independent input channels for different measurement schemes, allowing simultaneous multi‐parameter measurements to detect analytes of interest. Combined optical and thermal readout for spectroscopy is implemented by installing two different analog front‐end modules in the four input channels equipped with a micro spectrometer and a high‐resolution temperature sensor, respectively. The readout system is utilized to measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. Gold nanoparticles are modified with Guanine‐rich DNA sequences to perform Förster Resonance Energy Transfer (FRET) measurements. Elongation of DNA sequences at higher temperatures resulted in stronger fluorescence signals, accurately recorded by the portable system. The precision electronic components are chosen for a precise, battery‐powered operation. The size of this versatile, compact, and portable instrument is only 15.6 × 10.6 cm2. An interactive graphical‐user‐interface developed for this system supports point‐of‐care usage. The measurements carried out with the portable system showed a very close match with a commercial set‐up, with deviations less than 1 nm in the optical spectra and less than 0.5 °C in temperature.
A portable, battery‐powered, multi‐purpose readout system is developed and used for combined optical and thermal measurements. The system can measure fluorescence signals of a common dye functionalized on gold nanoparticle‐DNA conjugates as a function of the temperature. The measurements with the portable readout system demonstrate a very close match with an industrial measurement set‐up.</abstract><pub>Wiley-VCH</pub><doi>10.1002/adsr.202400105</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0002-6481-2257</orcidid><orcidid>https://orcid.org/0000-0002-0405-2727</orcidid><orcidid>https://orcid.org/0000-0002-9094-849X</orcidid><orcidid>https://orcid.org/0000-0003-3275-2429</orcidid><orcidid>https://orcid.org/0000-0001-6979-3510</orcidid><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2751-1219 |
ispartof | Advanced Sensor Research, 2025-01, Vol.4 (1), p.n/a |
issn | 2751-1219 2751-1219 |
language | eng |
recordid | cdi_crossref_primary_10_1002_adsr_202400105 |
source | DOAJ Directory of Open Access Journals; Wiley-Blackwell Open Access Titles; Alma/SFX Local Collection |
subjects | DNA fluorescence spectroscopy FRET gold nanoparticles optical spectroscopy point‐of‐care portable readout system |
title | Modular Multi‐Parametric and Portable Readout System for Point‐of‐Care Applications |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-21T18%3A39%3A22IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_doaj_&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Modular%20Multi%E2%80%90Parametric%20and%20Portable%20Readout%20System%20for%20Point%E2%80%90of%E2%80%90Care%20Applications&rft.jtitle=Advanced%20Sensor%20Research&rft.au=Khan,%20Dibyendu&rft.date=2025-01&rft.volume=4&rft.issue=1&rft.epage=n/a&rft.issn=2751-1219&rft.eissn=2751-1219&rft_id=info:doi/10.1002/adsr.202400105&rft_dat=%3Cwiley_doaj_%3EADSR12333%3C/wiley_doaj_%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_doaj_id=oai_doaj_org_article_cc073a61f92c4b09ba306e7e0f2abb17&rfr_iscdi=true |