Gold Layers on Elastomers near the Critical Stress Regime

Soft electrodes are essential components of soft robotics, tunable optics, microfluidics, flexible electronics, neuroprosthetics, and dielectric elastomeric transducers (DET). The two main paths employed to increase an electrode's compliance involve the manipulation of either its intrinsic mate...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Advanced materials technologies 2017-10, Vol.2 (10), p.n/a
Hauptverfasser: Osmani, Bekim, Deyhle, Hans, Töpper, Tino, Pfohl, Thomas, Müller, Bert
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page n/a
container_issue 10
container_start_page
container_title Advanced materials technologies
container_volume 2
creator Osmani, Bekim
Deyhle, Hans
Töpper, Tino
Pfohl, Thomas
Müller, Bert
description Soft electrodes are essential components of soft robotics, tunable optics, microfluidics, flexible electronics, neuroprosthetics, and dielectric elastomeric transducers (DET). The two main paths employed to increase an electrode's compliance involve the manipulation of either its intrinsic material properties or its structural features, such as the introduction of wrinkles, which arise above the critical stress of metal films on elastomeric substrates. Herein, this study demonstrates that the interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited metal electrodes allows for conserving compressive stress within the electrode. Insulator–metal transition already occurs for 10 nm thin Au electrodes, and below this electrode thickness, atomic force microscopy nanoindentations with sub‐micrometer resolutions reveal no stiffening of the Au/PDMS heterostructure. These DETs exhibit reduced electrocreasing, which is a significant contributor to structural failure, while their enhanced dielectric breakdown field of up to 120 V µm–1 enables calculated strains above 10% — a crucial requirement for thin‐film DETs such as those used for artificial muscles. The interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited Au electrodes enables the conservation of compressive stress on the top layer. Its mechanical compliance is increased through structural features, such as the introduction of wrinkles by oxygen‐plasma treatment. Atomic force microscopy nanoindentations with sub‐micrometer mapping reveal anisotropies in the elastic modulus for the plasma‐treated PDMS films.
doi_str_mv 10.1002/admt.201700105
format Article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_admt_201700105</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ADMT201700105</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3265-1b9b9cd296264d87b015c962024c10b01bf3bf1a47286119a62da576cdcaccb3</originalsourceid><addsrcrecordid>eNqFj01LxDAQhoMouKx79Zw_0DqTtmlzXOq6LlQE7cFbyFe10m4lKUj_vS0r6s3TzAPvM8NLyDVCjADsRtl-jBlgDoCQnZEVS3gW5SBezv_sl2QTwjvMGYE8KdiKiP3QWVqpyflAhyPddSqMQ7_Q0SlPxzdHS9-OrVEdfR69C4E-ude2d1fkolFdcJvvuSb13a4u76PqcX8ot1VkEja_RS20MJYJznhqi1wDZmYGYKlBmEk3iW5QpTkrOKJQnFmV5dxYo4zRyZrEp7PGDyF418gP3_bKTxJBLtXlUl3-VJ8FcRI-285N_6Tl9vah_nW_ANFnXIw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Gold Layers on Elastomers near the Critical Stress Regime</title><source>Wiley Journals</source><creator>Osmani, Bekim ; Deyhle, Hans ; Töpper, Tino ; Pfohl, Thomas ; Müller, Bert</creator><creatorcontrib>Osmani, Bekim ; Deyhle, Hans ; Töpper, Tino ; Pfohl, Thomas ; Müller, Bert</creatorcontrib><description>Soft electrodes are essential components of soft robotics, tunable optics, microfluidics, flexible electronics, neuroprosthetics, and dielectric elastomeric transducers (DET). The two main paths employed to increase an electrode's compliance involve the manipulation of either its intrinsic material properties or its structural features, such as the introduction of wrinkles, which arise above the critical stress of metal films on elastomeric substrates. Herein, this study demonstrates that the interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited metal electrodes allows for conserving compressive stress within the electrode. Insulator–metal transition already occurs for 10 nm thin Au electrodes, and below this electrode thickness, atomic force microscopy nanoindentations with sub‐micrometer resolutions reveal no stiffening of the Au/PDMS heterostructure. These DETs exhibit reduced electrocreasing, which is a significant contributor to structural failure, while their enhanced dielectric breakdown field of up to 120 V µm–1 enables calculated strains above 10% — a crucial requirement for thin‐film DETs such as those used for artificial muscles. The interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited Au electrodes enables the conservation of compressive stress on the top layer. Its mechanical compliance is increased through structural features, such as the introduction of wrinkles by oxygen‐plasma treatment. Atomic force microscopy nanoindentations with sub‐micrometer mapping reveal anisotropies in the elastic modulus for the plasma‐treated PDMS films.</description><identifier>ISSN: 2365-709X</identifier><identifier>EISSN: 2365-709X</identifier><identifier>DOI: 10.1002/admt.201700105</identifier><language>eng</language><subject>AFM nanoindentations ; dielectric elastomer transducers ; metal‐on‐elastomer films ; oxygen‐plasma treatment of PDMS ; soft electrodes</subject><ispartof>Advanced materials technologies, 2017-10, Vol.2 (10), p.n/a</ispartof><rights>2017 WILEY‐VCH Verlag GmbH &amp; Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3265-1b9b9cd296264d87b015c962024c10b01bf3bf1a47286119a62da576cdcaccb3</citedby><cites>FETCH-LOGICAL-c3265-1b9b9cd296264d87b015c962024c10b01bf3bf1a47286119a62da576cdcaccb3</cites><orcidid>0000-0003-4078-9109</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><linktopdf>$$Uhttps://onlinelibrary.wiley.com/doi/pdf/10.1002%2Fadmt.201700105$$EPDF$$P50$$Gwiley$$H</linktopdf><linktohtml>$$Uhttps://onlinelibrary.wiley.com/doi/full/10.1002%2Fadmt.201700105$$EHTML$$P50$$Gwiley$$H</linktohtml><link.rule.ids>314,780,784,1417,27924,27925,45574,45575</link.rule.ids></links><search><creatorcontrib>Osmani, Bekim</creatorcontrib><creatorcontrib>Deyhle, Hans</creatorcontrib><creatorcontrib>Töpper, Tino</creatorcontrib><creatorcontrib>Pfohl, Thomas</creatorcontrib><creatorcontrib>Müller, Bert</creatorcontrib><title>Gold Layers on Elastomers near the Critical Stress Regime</title><title>Advanced materials technologies</title><description>Soft electrodes are essential components of soft robotics, tunable optics, microfluidics, flexible electronics, neuroprosthetics, and dielectric elastomeric transducers (DET). The two main paths employed to increase an electrode's compliance involve the manipulation of either its intrinsic material properties or its structural features, such as the introduction of wrinkles, which arise above the critical stress of metal films on elastomeric substrates. Herein, this study demonstrates that the interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited metal electrodes allows for conserving compressive stress within the electrode. Insulator–metal transition already occurs for 10 nm thin Au electrodes, and below this electrode thickness, atomic force microscopy nanoindentations with sub‐micrometer resolutions reveal no stiffening of the Au/PDMS heterostructure. These DETs exhibit reduced electrocreasing, which is a significant contributor to structural failure, while their enhanced dielectric breakdown field of up to 120 V µm–1 enables calculated strains above 10% — a crucial requirement for thin‐film DETs such as those used for artificial muscles. The interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited Au electrodes enables the conservation of compressive stress on the top layer. Its mechanical compliance is increased through structural features, such as the introduction of wrinkles by oxygen‐plasma treatment. Atomic force microscopy nanoindentations with sub‐micrometer mapping reveal anisotropies in the elastic modulus for the plasma‐treated PDMS films.</description><subject>AFM nanoindentations</subject><subject>dielectric elastomer transducers</subject><subject>metal‐on‐elastomer films</subject><subject>oxygen‐plasma treatment of PDMS</subject><subject>soft electrodes</subject><issn>2365-709X</issn><issn>2365-709X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><recordid>eNqFj01LxDAQhoMouKx79Zw_0DqTtmlzXOq6LlQE7cFbyFe10m4lKUj_vS0r6s3TzAPvM8NLyDVCjADsRtl-jBlgDoCQnZEVS3gW5SBezv_sl2QTwjvMGYE8KdiKiP3QWVqpyflAhyPddSqMQ7_Q0SlPxzdHS9-OrVEdfR69C4E-ude2d1fkolFdcJvvuSb13a4u76PqcX8ot1VkEja_RS20MJYJznhqi1wDZmYGYKlBmEk3iW5QpTkrOKJQnFmV5dxYo4zRyZrEp7PGDyF418gP3_bKTxJBLtXlUl3-VJ8FcRI-285N_6Tl9vah_nW_ANFnXIw</recordid><startdate>201710</startdate><enddate>201710</enddate><creator>Osmani, Bekim</creator><creator>Deyhle, Hans</creator><creator>Töpper, Tino</creator><creator>Pfohl, Thomas</creator><creator>Müller, Bert</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0003-4078-9109</orcidid></search><sort><creationdate>201710</creationdate><title>Gold Layers on Elastomers near the Critical Stress Regime</title><author>Osmani, Bekim ; Deyhle, Hans ; Töpper, Tino ; Pfohl, Thomas ; Müller, Bert</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3265-1b9b9cd296264d87b015c962024c10b01bf3bf1a47286119a62da576cdcaccb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>AFM nanoindentations</topic><topic>dielectric elastomer transducers</topic><topic>metal‐on‐elastomer films</topic><topic>oxygen‐plasma treatment of PDMS</topic><topic>soft electrodes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Osmani, Bekim</creatorcontrib><creatorcontrib>Deyhle, Hans</creatorcontrib><creatorcontrib>Töpper, Tino</creatorcontrib><creatorcontrib>Pfohl, Thomas</creatorcontrib><creatorcontrib>Müller, Bert</creatorcontrib><collection>CrossRef</collection><jtitle>Advanced materials technologies</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Osmani, Bekim</au><au>Deyhle, Hans</au><au>Töpper, Tino</au><au>Pfohl, Thomas</au><au>Müller, Bert</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Gold Layers on Elastomers near the Critical Stress Regime</atitle><jtitle>Advanced materials technologies</jtitle><date>2017-10</date><risdate>2017</risdate><volume>2</volume><issue>10</issue><epage>n/a</epage><issn>2365-709X</issn><eissn>2365-709X</eissn><abstract>Soft electrodes are essential components of soft robotics, tunable optics, microfluidics, flexible electronics, neuroprosthetics, and dielectric elastomeric transducers (DET). The two main paths employed to increase an electrode's compliance involve the manipulation of either its intrinsic material properties or its structural features, such as the introduction of wrinkles, which arise above the critical stress of metal films on elastomeric substrates. Herein, this study demonstrates that the interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited metal electrodes allows for conserving compressive stress within the electrode. Insulator–metal transition already occurs for 10 nm thin Au electrodes, and below this electrode thickness, atomic force microscopy nanoindentations with sub‐micrometer resolutions reveal no stiffening of the Au/PDMS heterostructure. These DETs exhibit reduced electrocreasing, which is a significant contributor to structural failure, while their enhanced dielectric breakdown field of up to 120 V µm–1 enables calculated strains above 10% — a crucial requirement for thin‐film DETs such as those used for artificial muscles. The interplay between functionalized oxygen‐plasma‐treated polydimethylsiloxane (PDMS) films and sputter‐deposited Au electrodes enables the conservation of compressive stress on the top layer. Its mechanical compliance is increased through structural features, such as the introduction of wrinkles by oxygen‐plasma treatment. Atomic force microscopy nanoindentations with sub‐micrometer mapping reveal anisotropies in the elastic modulus for the plasma‐treated PDMS films.</abstract><doi>10.1002/admt.201700105</doi><tpages>9</tpages><orcidid>https://orcid.org/0000-0003-4078-9109</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2365-709X
ispartof Advanced materials technologies, 2017-10, Vol.2 (10), p.n/a
issn 2365-709X
2365-709X
language eng
recordid cdi_crossref_primary_10_1002_admt_201700105
source Wiley Journals
subjects AFM nanoindentations
dielectric elastomer transducers
metal‐on‐elastomer films
oxygen‐plasma treatment of PDMS
soft electrodes
title Gold Layers on Elastomers near the Critical Stress Regime
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-05T08%3A53%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Gold%20Layers%20on%20Elastomers%20near%20the%20Critical%20Stress%20Regime&rft.jtitle=Advanced%20materials%20technologies&rft.au=Osmani,%20Bekim&rft.date=2017-10&rft.volume=2&rft.issue=10&rft.epage=n/a&rft.issn=2365-709X&rft.eissn=2365-709X&rft_id=info:doi/10.1002/admt.201700105&rft_dat=%3Cwiley_cross%3EADMT201700105%3C/wiley_cross%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true