Cardiac power integral: a new method for monitoring cardiovascular performance

Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjec...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Rimehaug, Audun Eskeland, Lyng, Oddveig, Nordhaug, Dag Ole, Løvstakken, Lasse, Aadahl, Petter, Kirkeby-Garstad, Idar
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Rimehaug, Audun Eskeland
Lyng, Oddveig
Nordhaug, Dag Ole
Løvstakken, Lasse
Aadahl, Petter
Kirkeby-Garstad, Idar
description Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesthesia equipped with transit time flow probes on their proximal aortas and Millar micromanometer catheters in their descending aortas to measure PWR, and Leycom conductance catheters in their left ventricles to measure SW. The PWR integral was calculated as the time integral of PWR per cardiac cycle. SW was calculated as the area encompassed by the pressure– volume loop (PV loop). The relationship between the PWR integral and SW was tested during extensive mechanical and pharmacological interventions that affected the loading conditions and myocardial contractility. The PWR integral displayed a strong correlation with SW in all pigs (R2 > 0.95, P < 0.05) under all conditions, using a linear model. Regression analysis and Bland Altman plots also demonstrated a stable relationship. A mixed linear analysis indicated that the slope of the SW-to-PWR-integral relationship was similar among all six animals, whereas loading and contractility conditions tended to affect the slope. The PWR integral followed SW and appeared to be a promising parameter for monitoring the energy transferred from the left ventricle to the aorta. This conclusion motivates further studies to determine whether the PWR integral can be evaluated using less invasive methods, such as echocardiography combined with a radial artery catheter.
format Article
fullrecord <record><control><sourceid>cristin_3HK</sourceid><recordid>TN_cdi_cristin_nora_11250_299777</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>11250_299777</sourcerecordid><originalsourceid>FETCH-cristin_nora_11250_2997773</originalsourceid><addsrcrecordid>eNqNyzEKwkAQQNE0FqLeYS4gmIgsSRsUKyv7ZdhM4sDuTJhdzfVV8ABWv3l_Xd16tIExwKwLGbAUmgxjBwhCCyQqDx1gVIOkwkWNZYLwffSFOTwjGsxkH5BQAm2r1Ygx0-7XTQWX872_7oNxLixe1NDXdXM6-KZtnXPHP8gbs9s2Mw</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Cardiac power integral: a new method for monitoring cardiovascular performance</title><source>NORA - Norwegian Open Research Archives</source><creator>Rimehaug, Audun Eskeland ; Lyng, Oddveig ; Nordhaug, Dag Ole ; Løvstakken, Lasse ; Aadahl, Petter ; Kirkeby-Garstad, Idar</creator><creatorcontrib>Rimehaug, Audun Eskeland ; Lyng, Oddveig ; Nordhaug, Dag Ole ; Løvstakken, Lasse ; Aadahl, Petter ; Kirkeby-Garstad, Idar</creatorcontrib><description>Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesthesia equipped with transit time flow probes on their proximal aortas and Millar micromanometer catheters in their descending aortas to measure PWR, and Leycom conductance catheters in their left ventricles to measure SW. The PWR integral was calculated as the time integral of PWR per cardiac cycle. SW was calculated as the area encompassed by the pressure– volume loop (PV loop). The relationship between the PWR integral and SW was tested during extensive mechanical and pharmacological interventions that affected the loading conditions and myocardial contractility. The PWR integral displayed a strong correlation with SW in all pigs (R2 &gt; 0.95, P &lt; 0.05) under all conditions, using a linear model. Regression analysis and Bland Altman plots also demonstrated a stable relationship. A mixed linear analysis indicated that the slope of the SW-to-PWR-integral relationship was similar among all six animals, whereas loading and contractility conditions tended to affect the slope. The PWR integral followed SW and appeared to be a promising parameter for monitoring the energy transferred from the left ventricle to the aorta. This conclusion motivates further studies to determine whether the PWR integral can be evaluated using less invasive methods, such as echocardiography combined with a radial artery catheter.</description><language>eng</language><publisher>Wiley Open Access</publisher><creationdate>2013</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,26567</link.rule.ids><linktorsrc>$$Uhttp://hdl.handle.net/11250/299777$$EView_record_in_NORA$$FView_record_in_$$GNORA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Rimehaug, Audun Eskeland</creatorcontrib><creatorcontrib>Lyng, Oddveig</creatorcontrib><creatorcontrib>Nordhaug, Dag Ole</creatorcontrib><creatorcontrib>Løvstakken, Lasse</creatorcontrib><creatorcontrib>Aadahl, Petter</creatorcontrib><creatorcontrib>Kirkeby-Garstad, Idar</creatorcontrib><title>Cardiac power integral: a new method for monitoring cardiovascular performance</title><description>Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesthesia equipped with transit time flow probes on their proximal aortas and Millar micromanometer catheters in their descending aortas to measure PWR, and Leycom conductance catheters in their left ventricles to measure SW. The PWR integral was calculated as the time integral of PWR per cardiac cycle. SW was calculated as the area encompassed by the pressure– volume loop (PV loop). The relationship between the PWR integral and SW was tested during extensive mechanical and pharmacological interventions that affected the loading conditions and myocardial contractility. The PWR integral displayed a strong correlation with SW in all pigs (R2 &gt; 0.95, P &lt; 0.05) under all conditions, using a linear model. Regression analysis and Bland Altman plots also demonstrated a stable relationship. A mixed linear analysis indicated that the slope of the SW-to-PWR-integral relationship was similar among all six animals, whereas loading and contractility conditions tended to affect the slope. The PWR integral followed SW and appeared to be a promising parameter for monitoring the energy transferred from the left ventricle to the aorta. This conclusion motivates further studies to determine whether the PWR integral can be evaluated using less invasive methods, such as echocardiography combined with a radial artery catheter.</description><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2013</creationdate><recordtype>article</recordtype><sourceid>3HK</sourceid><recordid>eNqNyzEKwkAQQNE0FqLeYS4gmIgsSRsUKyv7ZdhM4sDuTJhdzfVV8ABWv3l_Xd16tIExwKwLGbAUmgxjBwhCCyQqDx1gVIOkwkWNZYLwffSFOTwjGsxkH5BQAm2r1Ygx0-7XTQWX872_7oNxLixe1NDXdXM6-KZtnXPHP8gbs9s2Mw</recordid><startdate>2013</startdate><enddate>2013</enddate><creator>Rimehaug, Audun Eskeland</creator><creator>Lyng, Oddveig</creator><creator>Nordhaug, Dag Ole</creator><creator>Løvstakken, Lasse</creator><creator>Aadahl, Petter</creator><creator>Kirkeby-Garstad, Idar</creator><general>Wiley Open Access</general><scope>3HK</scope></search><sort><creationdate>2013</creationdate><title>Cardiac power integral: a new method for monitoring cardiovascular performance</title><author>Rimehaug, Audun Eskeland ; Lyng, Oddveig ; Nordhaug, Dag Ole ; Løvstakken, Lasse ; Aadahl, Petter ; Kirkeby-Garstad, Idar</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-cristin_nora_11250_2997773</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2013</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Rimehaug, Audun Eskeland</creatorcontrib><creatorcontrib>Lyng, Oddveig</creatorcontrib><creatorcontrib>Nordhaug, Dag Ole</creatorcontrib><creatorcontrib>Løvstakken, Lasse</creatorcontrib><creatorcontrib>Aadahl, Petter</creatorcontrib><creatorcontrib>Kirkeby-Garstad, Idar</creatorcontrib><collection>NORA - Norwegian Open Research Archives</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Rimehaug, Audun Eskeland</au><au>Lyng, Oddveig</au><au>Nordhaug, Dag Ole</au><au>Løvstakken, Lasse</au><au>Aadahl, Petter</au><au>Kirkeby-Garstad, Idar</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Cardiac power integral: a new method for monitoring cardiovascular performance</atitle><date>2013</date><risdate>2013</risdate><abstract>Cardiac power (PWR) is the continuous product of flow and pressure in the proximal aorta. Our aim was to validate the PWR integral as a marker of left ventricular energy transfer to the aorta, by comparing it to stroke work (SW) under multiple different loading and contractility conditions in subjects without obstructions in the left ventricular outflow tract. Six pigs were under general anesthesia equipped with transit time flow probes on their proximal aortas and Millar micromanometer catheters in their descending aortas to measure PWR, and Leycom conductance catheters in their left ventricles to measure SW. The PWR integral was calculated as the time integral of PWR per cardiac cycle. SW was calculated as the area encompassed by the pressure– volume loop (PV loop). The relationship between the PWR integral and SW was tested during extensive mechanical and pharmacological interventions that affected the loading conditions and myocardial contractility. The PWR integral displayed a strong correlation with SW in all pigs (R2 &gt; 0.95, P &lt; 0.05) under all conditions, using a linear model. Regression analysis and Bland Altman plots also demonstrated a stable relationship. A mixed linear analysis indicated that the slope of the SW-to-PWR-integral relationship was similar among all six animals, whereas loading and contractility conditions tended to affect the slope. The PWR integral followed SW and appeared to be a promising parameter for monitoring the energy transferred from the left ventricle to the aorta. This conclusion motivates further studies to determine whether the PWR integral can be evaluated using less invasive methods, such as echocardiography combined with a radial artery catheter.</abstract><pub>Wiley Open Access</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_cristin_nora_11250_299777
source NORA - Norwegian Open Research Archives
title Cardiac power integral: a new method for monitoring cardiovascular performance
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-03T05%3A11%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cristin_3HK&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Cardiac%20power%20integral:%20a%20new%20method%20for%20monitoring%20cardiovascular%20performance&rft.au=Rimehaug,%20Audun%20Eskeland&rft.date=2013&rft_id=info:doi/&rft_dat=%3Ccristin_3HK%3E11250_299777%3C/cristin_3HK%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true