Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling

While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Snow, Melanie A, Darko, Godfred, Gyamfi, Opoku, Ansah, Eugene, Breivik, Knut, Hoang, Christopher, Lei, Ying Duan, Wania, Frank
Format: Artikel
Sprache:eng
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Snow, Melanie A
Darko, Godfred
Gyamfi, Opoku
Ansah, Eugene
Breivik, Knut
Hoang, Christopher
Lei, Ying Duan
Wania, Frank
description While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products. Recently, stationary and personal passive air samplers based on activated carbon sorbents and radial diffusive barriers have been shown to be suitable for measuring GEM concentrations across the range relevant for chronic health effects. Here, we used a combination of stationary and personal passive samplers to characterize the inhalation exposure to GEM of individuals living and working in two Ghanaian gold mining communities and working at a Norwegian e-waste recycling facility. Exposure concentrations ranging from 500 μg m−3 were observed, with the higher end of the range occurring in one gold mining community. Large differences in the GEM exposure averaged over the length of a workday between individuals can be rationalized by their activity and proximity to mercury sources. In each of the three settings, the measured exposure of the highest exposed individuals exceeded the highest concentration recorded with a stationary sampler, presumably because those individuals were engaged in an activity that generated or involved GEM vapors. High day-to-day variability in exposure for those who participated on more than one day, suggests the need for sampling over multiple days for reliable exposure characterization. Overall, a combination of personal and stationary passive sampling is a cost-effective approach that cannot only provide information on exposure levels relative to regulatory thresholds, but also can identify emission hotspots and therefore guide mitigation measures.
format Article
fullrecord <record><control><sourceid>cristin_3HK</sourceid><recordid>TN_cdi_cristin_nora_11250_2728905</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>11250_2728905</sourcerecordid><originalsourceid>FETCH-cristin_nora_11250_27289053</originalsourceid><addsrcrecordid>eNqNTUtKA0EQnY0LUe9QHiCQjATjUsYxuggEE3A5lD2VTEFPVajqFuOtvKFp9QCuHu9_Xn01AxqGRMafmFgFdAfPMmD8Ze3HQT0bQVJYopNmhzbSSJIwwoosZDvCQzaWPdxbYkc5GUuNPaxYiorSQzt5RU8ELxSOIRZ1O5jm_QCNjm8s1MMm_Tziaa401mSuZWqN7vxOsMHxUJqX1dkOo9PVH15U14_ttnmaBGNPLJ2oYTeb1fNpV9_Wi7vp_OY_mW9mZlrW</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling</title><source>NORA - Norwegian Open Research Archives</source><creator>Snow, Melanie A ; Darko, Godfred ; Gyamfi, Opoku ; Ansah, Eugene ; Breivik, Knut ; Hoang, Christopher ; Lei, Ying Duan ; Wania, Frank</creator><creatorcontrib>Snow, Melanie A ; Darko, Godfred ; Gyamfi, Opoku ; Ansah, Eugene ; Breivik, Knut ; Hoang, Christopher ; Lei, Ying Duan ; Wania, Frank</creatorcontrib><description>While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products. Recently, stationary and personal passive air samplers based on activated carbon sorbents and radial diffusive barriers have been shown to be suitable for measuring GEM concentrations across the range relevant for chronic health effects. Here, we used a combination of stationary and personal passive samplers to characterize the inhalation exposure to GEM of individuals living and working in two Ghanaian gold mining communities and working at a Norwegian e-waste recycling facility. Exposure concentrations ranging from &lt;7 ng m−3 to &gt;500 μg m−3 were observed, with the higher end of the range occurring in one gold mining community. Large differences in the GEM exposure averaged over the length of a workday between individuals can be rationalized by their activity and proximity to mercury sources. In each of the three settings, the measured exposure of the highest exposed individuals exceeded the highest concentration recorded with a stationary sampler, presumably because those individuals were engaged in an activity that generated or involved GEM vapors. High day-to-day variability in exposure for those who participated on more than one day, suggests the need for sampling over multiple days for reliable exposure characterization. Overall, a combination of personal and stationary passive sampling is a cost-effective approach that cannot only provide information on exposure levels relative to regulatory thresholds, but also can identify emission hotspots and therefore guide mitigation measures.</description><language>eng</language><creationdate>2021</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,780,885,26567</link.rule.ids><linktorsrc>$$Uhttp://hdl.handle.net/11250/2728905$$EView_record_in_NORA$$FView_record_in_$$GNORA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Snow, Melanie A</creatorcontrib><creatorcontrib>Darko, Godfred</creatorcontrib><creatorcontrib>Gyamfi, Opoku</creatorcontrib><creatorcontrib>Ansah, Eugene</creatorcontrib><creatorcontrib>Breivik, Knut</creatorcontrib><creatorcontrib>Hoang, Christopher</creatorcontrib><creatorcontrib>Lei, Ying Duan</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><title>Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling</title><description>While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products. Recently, stationary and personal passive air samplers based on activated carbon sorbents and radial diffusive barriers have been shown to be suitable for measuring GEM concentrations across the range relevant for chronic health effects. Here, we used a combination of stationary and personal passive samplers to characterize the inhalation exposure to GEM of individuals living and working in two Ghanaian gold mining communities and working at a Norwegian e-waste recycling facility. Exposure concentrations ranging from &lt;7 ng m−3 to &gt;500 μg m−3 were observed, with the higher end of the range occurring in one gold mining community. Large differences in the GEM exposure averaged over the length of a workday between individuals can be rationalized by their activity and proximity to mercury sources. In each of the three settings, the measured exposure of the highest exposed individuals exceeded the highest concentration recorded with a stationary sampler, presumably because those individuals were engaged in an activity that generated or involved GEM vapors. High day-to-day variability in exposure for those who participated on more than one day, suggests the need for sampling over multiple days for reliable exposure characterization. Overall, a combination of personal and stationary passive sampling is a cost-effective approach that cannot only provide information on exposure levels relative to regulatory thresholds, but also can identify emission hotspots and therefore guide mitigation measures.</description><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><sourceid>3HK</sourceid><recordid>eNqNTUtKA0EQnY0LUe9QHiCQjATjUsYxuggEE3A5lD2VTEFPVajqFuOtvKFp9QCuHu9_Xn01AxqGRMafmFgFdAfPMmD8Ze3HQT0bQVJYopNmhzbSSJIwwoosZDvCQzaWPdxbYkc5GUuNPaxYiorSQzt5RU8ELxSOIRZ1O5jm_QCNjm8s1MMm_Tziaa401mSuZWqN7vxOsMHxUJqX1dkOo9PVH15U14_ttnmaBGNPLJ2oYTeb1fNpV9_Wi7vp_OY_mW9mZlrW</recordid><startdate>2021</startdate><enddate>2021</enddate><creator>Snow, Melanie A</creator><creator>Darko, Godfred</creator><creator>Gyamfi, Opoku</creator><creator>Ansah, Eugene</creator><creator>Breivik, Knut</creator><creator>Hoang, Christopher</creator><creator>Lei, Ying Duan</creator><creator>Wania, Frank</creator><scope>3HK</scope></search><sort><creationdate>2021</creationdate><title>Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling</title><author>Snow, Melanie A ; Darko, Godfred ; Gyamfi, Opoku ; Ansah, Eugene ; Breivik, Knut ; Hoang, Christopher ; Lei, Ying Duan ; Wania, Frank</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-cristin_nora_11250_27289053</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><toplevel>online_resources</toplevel><creatorcontrib>Snow, Melanie A</creatorcontrib><creatorcontrib>Darko, Godfred</creatorcontrib><creatorcontrib>Gyamfi, Opoku</creatorcontrib><creatorcontrib>Ansah, Eugene</creatorcontrib><creatorcontrib>Breivik, Knut</creatorcontrib><creatorcontrib>Hoang, Christopher</creatorcontrib><creatorcontrib>Lei, Ying Duan</creatorcontrib><creatorcontrib>Wania, Frank</creatorcontrib><collection>NORA - Norwegian Open Research Archives</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Snow, Melanie A</au><au>Darko, Godfred</au><au>Gyamfi, Opoku</au><au>Ansah, Eugene</au><au>Breivik, Knut</au><au>Hoang, Christopher</au><au>Lei, Ying Duan</au><au>Wania, Frank</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling</atitle><date>2021</date><risdate>2021</risdate><abstract>While occupational inhalation exposure to gaseous elemental mercury (GEM) has decreased in many workplaces as mercury is being removed from most products and processes, it continues to be a concern for those engaged in artisanal and small-scale gold mining or in recycling mercury-containing products. Recently, stationary and personal passive air samplers based on activated carbon sorbents and radial diffusive barriers have been shown to be suitable for measuring GEM concentrations across the range relevant for chronic health effects. Here, we used a combination of stationary and personal passive samplers to characterize the inhalation exposure to GEM of individuals living and working in two Ghanaian gold mining communities and working at a Norwegian e-waste recycling facility. Exposure concentrations ranging from &lt;7 ng m−3 to &gt;500 μg m−3 were observed, with the higher end of the range occurring in one gold mining community. Large differences in the GEM exposure averaged over the length of a workday between individuals can be rationalized by their activity and proximity to mercury sources. In each of the three settings, the measured exposure of the highest exposed individuals exceeded the highest concentration recorded with a stationary sampler, presumably because those individuals were engaged in an activity that generated or involved GEM vapors. High day-to-day variability in exposure for those who participated on more than one day, suggests the need for sampling over multiple days for reliable exposure characterization. Overall, a combination of personal and stationary passive sampling is a cost-effective approach that cannot only provide information on exposure levels relative to regulatory thresholds, but also can identify emission hotspots and therefore guide mitigation measures.</abstract><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_cristin_nora_11250_2728905
source NORA - Norwegian Open Research Archives
title Characterization of Inhalation Exposure to Gaseous Elemental Mercury During Artisanal Gold Mining and E-Waste Recycling Through Combined Stationary and Personal Passive Sampling
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-20T09%3A15%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cristin_3HK&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Characterization%20of%20Inhalation%20Exposure%20to%20Gaseous%20Elemental%20Mercury%20During%20Artisanal%20Gold%20Mining%20and%20E-Waste%20Recycling%20Through%20Combined%20Stationary%20and%20Personal%20Passive%20Sampling&rft.au=Snow,%20Melanie%20A&rft.date=2021&rft_id=info:doi/&rft_dat=%3Ccristin_3HK%3E11250_2728905%3C/cristin_3HK%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true