Analysis of the impact resolution has on load matching in the Norwegian context

Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Hauptverfasser: Sørnes, Kari, Fredriksen, Eyvind, Tunheim, Ketil, Sartori, Igor
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext bestellen
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title
container_volume
creator Sørnes, Kari
Fredriksen, Eyvind
Tunheim, Ketil
Sartori, Igor
description Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it is of interest to study the choice of resolution and what impact this has on load match indicators. This study analyses the importance of choosing the right resolution, starting with hourly measurements, and going down towards one-minute resolution. Monitoring resolution has a significant impact on both the type of monitoring equipment and the data storage capacity needed. If the impact of lower resolution is small, less complex monitoring systems can be installed in projects that are not sensible to the uncertainty caused by the lack of minute-based data. Norwegian case studies with solar power production gives data to the analysis, studying a nursing home in Oslo called Økern Sykehjem. The nursing home has been a pilot building in the European Fp7 research project ZenN, Nearly Zero Energy Neighbourhood (2012-2017), which led to the installation of 130 kW solar power panels while going through a large renovation process. Generation and load have been monitored with high-resolution since 2015 and this gives useful insight into the effect of high-resolution data monitoring compared to hourly-resolution monitoring. Resulting graphs shows that by collecting data on a daily basis will give a wrong impression on self-consumption and self-generation by about 20% compared to hourly based data. The difference between minute based and hourly based resolution is relatively small (6%)
format Article
fullrecord <record><control><sourceid>cristin_3HK</sourceid><recordid>TN_cdi_cristin_nora_11250_2468187</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>11250_2468187</sourcerecordid><originalsourceid>FETCH-cristin_nora_11250_24681873</originalsourceid><addsrcrecordid>eNqNyj0KAjEQQOE0FrJ6h_EAC2b921ZEsdLGPgwxuxnIzkgyot5eEQ9g9Yr3jc15y5hehQpIBxoD0HBDr5BDkXRXEoaIn8mQBK8woPpI3APxV58kP0JPyOCFNTx1YkYdphKmv1ZmdthfdsfaZypK7FgyOmub1dw1y3Vr283iH_MGKuE2YQ</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Analysis of the impact resolution has on load matching in the Norwegian context</title><source>NORA - Norwegian Open Research Archives</source><creator>Sørnes, Kari ; Fredriksen, Eyvind ; Tunheim, Ketil ; Sartori, Igor</creator><creatorcontrib>Sørnes, Kari ; Fredriksen, Eyvind ; Tunheim, Ketil ; Sartori, Igor</creatorcontrib><description>Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it is of interest to study the choice of resolution and what impact this has on load match indicators. This study analyses the importance of choosing the right resolution, starting with hourly measurements, and going down towards one-minute resolution. Monitoring resolution has a significant impact on both the type of monitoring equipment and the data storage capacity needed. If the impact of lower resolution is small, less complex monitoring systems can be installed in projects that are not sensible to the uncertainty caused by the lack of minute-based data. Norwegian case studies with solar power production gives data to the analysis, studying a nursing home in Oslo called Økern Sykehjem. The nursing home has been a pilot building in the European Fp7 research project ZenN, Nearly Zero Energy Neighbourhood (2012-2017), which led to the installation of 130 kW solar power panels while going through a large renovation process. Generation and load have been monitored with high-resolution since 2015 and this gives useful insight into the effect of high-resolution data monitoring compared to hourly-resolution monitoring. Resulting graphs shows that by collecting data on a daily basis will give a wrong impression on self-consumption and self-generation by about 20% compared to hourly based data. The difference between minute based and hourly based resolution is relatively small (6%)</description><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Buildings ; Complex monitoring system ; Data storage capacity ; Digital storage ; High resolution data ; Impact resolution ; Load matching ; Monitoring equipment ; nZEB ; Photovoltaic ; Solar energy</subject><creationdate>2017</creationdate><rights>info:eu-repo/semantics/openAccess</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,776,881,26544</link.rule.ids><linktorsrc>$$Uhttp://hdl.handle.net/11250/2468187$$EView_record_in_NORA$$FView_record_in_$$GNORA$$Hfree_for_read</linktorsrc></links><search><creatorcontrib>Sørnes, Kari</creatorcontrib><creatorcontrib>Fredriksen, Eyvind</creatorcontrib><creatorcontrib>Tunheim, Ketil</creatorcontrib><creatorcontrib>Sartori, Igor</creatorcontrib><title>Analysis of the impact resolution has on load matching in the Norwegian context</title><description>Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it is of interest to study the choice of resolution and what impact this has on load match indicators. This study analyses the importance of choosing the right resolution, starting with hourly measurements, and going down towards one-minute resolution. Monitoring resolution has a significant impact on both the type of monitoring equipment and the data storage capacity needed. If the impact of lower resolution is small, less complex monitoring systems can be installed in projects that are not sensible to the uncertainty caused by the lack of minute-based data. Norwegian case studies with solar power production gives data to the analysis, studying a nursing home in Oslo called Økern Sykehjem. The nursing home has been a pilot building in the European Fp7 research project ZenN, Nearly Zero Energy Neighbourhood (2012-2017), which led to the installation of 130 kW solar power panels while going through a large renovation process. Generation and load have been monitored with high-resolution since 2015 and this gives useful insight into the effect of high-resolution data monitoring compared to hourly-resolution monitoring. Resulting graphs shows that by collecting data on a daily basis will give a wrong impression on self-consumption and self-generation by about 20% compared to hourly based data. The difference between minute based and hourly based resolution is relatively small (6%)</description><subject>Buildings</subject><subject>Complex monitoring system</subject><subject>Data storage capacity</subject><subject>Digital storage</subject><subject>High resolution data</subject><subject>Impact resolution</subject><subject>Load matching</subject><subject>Monitoring equipment</subject><subject>nZEB</subject><subject>Photovoltaic</subject><subject>Solar energy</subject><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2017</creationdate><recordtype>article</recordtype><sourceid>3HK</sourceid><recordid>eNqNyj0KAjEQQOE0FrJ6h_EAC2b921ZEsdLGPgwxuxnIzkgyot5eEQ9g9Yr3jc15y5hehQpIBxoD0HBDr5BDkXRXEoaIn8mQBK8woPpI3APxV58kP0JPyOCFNTx1YkYdphKmv1ZmdthfdsfaZypK7FgyOmub1dw1y3Vr283iH_MGKuE2YQ</recordid><startdate>2017</startdate><enddate>2017</enddate><creator>Sørnes, Kari</creator><creator>Fredriksen, Eyvind</creator><creator>Tunheim, Ketil</creator><creator>Sartori, Igor</creator><general>Elsevier Ltd</general><scope>3HK</scope></search><sort><creationdate>2017</creationdate><title>Analysis of the impact resolution has on load matching in the Norwegian context</title><author>Sørnes, Kari ; Fredriksen, Eyvind ; Tunheim, Ketil ; Sartori, Igor</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-cristin_nora_11250_24681873</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2017</creationdate><topic>Buildings</topic><topic>Complex monitoring system</topic><topic>Data storage capacity</topic><topic>Digital storage</topic><topic>High resolution data</topic><topic>Impact resolution</topic><topic>Load matching</topic><topic>Monitoring equipment</topic><topic>nZEB</topic><topic>Photovoltaic</topic><topic>Solar energy</topic><toplevel>online_resources</toplevel><creatorcontrib>Sørnes, Kari</creatorcontrib><creatorcontrib>Fredriksen, Eyvind</creatorcontrib><creatorcontrib>Tunheim, Ketil</creatorcontrib><creatorcontrib>Sartori, Igor</creatorcontrib><collection>NORA - Norwegian Open Research Archives</collection></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext_linktorsrc</fulltext></delivery><addata><au>Sørnes, Kari</au><au>Fredriksen, Eyvind</au><au>Tunheim, Ketil</au><au>Sartori, Igor</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Analysis of the impact resolution has on load matching in the Norwegian context</atitle><date>2017</date><risdate>2017</risdate><abstract>Generation of energy at building level has an increasing interest in Norway, as in rest of Europe. Load matching is the correlation between the buildings generation and load, which in most cases aims at optimization of the amount of self-consumption. When analysing generation in relation to load, it is of interest to study the choice of resolution and what impact this has on load match indicators. This study analyses the importance of choosing the right resolution, starting with hourly measurements, and going down towards one-minute resolution. Monitoring resolution has a significant impact on both the type of monitoring equipment and the data storage capacity needed. If the impact of lower resolution is small, less complex monitoring systems can be installed in projects that are not sensible to the uncertainty caused by the lack of minute-based data. Norwegian case studies with solar power production gives data to the analysis, studying a nursing home in Oslo called Økern Sykehjem. The nursing home has been a pilot building in the European Fp7 research project ZenN, Nearly Zero Energy Neighbourhood (2012-2017), which led to the installation of 130 kW solar power panels while going through a large renovation process. Generation and load have been monitored with high-resolution since 2015 and this gives useful insight into the effect of high-resolution data monitoring compared to hourly-resolution monitoring. Resulting graphs shows that by collecting data on a daily basis will give a wrong impression on self-consumption and self-generation by about 20% compared to hourly based data. The difference between minute based and hourly based resolution is relatively small (6%)</abstract><pub>Elsevier Ltd</pub><oa>free_for_read</oa></addata></record>
fulltext fulltext_linktorsrc
identifier
ispartof
issn
language eng
recordid cdi_cristin_nora_11250_2468187
source NORA - Norwegian Open Research Archives
subjects Buildings
Complex monitoring system
Data storage capacity
Digital storage
High resolution data
Impact resolution
Load matching
Monitoring equipment
nZEB
Photovoltaic
Solar energy
title Analysis of the impact resolution has on load matching in the Norwegian context
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-13T15%3A13%3A04IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-cristin_3HK&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Analysis%20of%20the%20impact%20resolution%20has%20on%20load%20matching%20in%20the%20Norwegian%20context&rft.au=S%C3%B8rnes,%20Kari&rft.date=2017&rft_id=info:doi/&rft_dat=%3Ccristin_3HK%3E11250_2468187%3C/cristin_3HK%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true