Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450
Pb-Bi eutectic alloy has been receiving increasing attention as a heavy liquid metal coolant in accelerator driven systems and Generation IV fission reactors. Compatibility of structural materials with liquid PbBi eutectic alloy at high temperature is one of the issues concerned. In the present stud...
Gespeichert in:
Veröffentlicht in: | 中国铸造:英文版 2014 (3), p.197-200 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | 200 |
---|---|
container_issue | 3 |
container_start_page | 197 |
container_title | 中国铸造:英文版 |
container_volume | |
creator | Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei |
description | Pb-Bi eutectic alloy has been receiving increasing attention as a heavy liquid metal coolant in accelerator driven systems and Generation IV fission reactors. Compatibility of structural materials with liquid PbBi eutectic alloy at high temperature is one of the issues concerned. In the present study, corrosion tests of T91 steel in stagnant Pb-Bi eutectic alloy in saturated oxygen condition at 450 oC were carried out. After experiments, the thickness and compositional profile of the oxide layer on the specimen were analyzed using SEM and EDX. Analysis results show that the thickness of the oxide layer increases as the exposure time increases from 500 h to 1,000 h. The thickness of the oxide layer remains almost unchanged at 15 to 16 mm from 1,000 to 1,500 h. Formation of a thick and protective oxide layer at 450 oC prevents the penetration of liquid Pb-Bi eutectic alloy into the matrix of the T91 steel. |
format | Article |
fullrecord | <record><control><sourceid>chongqing</sourceid><recordid>TN_cdi_chongqing_primary_50132133</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>50132133</cqvip_id><sourcerecordid>50132133</sourcerecordid><originalsourceid>FETCH-chongqing_primary_501321333</originalsourceid><addsrcrecordid>eNqNyjEOgjAUgOHGaCJR7vA8AElLaZUVonF0YCcFCzxTKNASw-118AD-y7f8GxLEXIooTUS6JQGT5ziSScz2JHTuRb_Ji6RSBCTLbT8qjxUa9CvYBoqUgfNaG3ij78DgtOATHlWUIejF69pjDcoYu4LykAh6JLtGGafDnwdyul2L_B7VnR3aCYe2HGfs1byWgjIeM875P88Hf4M4sA</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450</title><source>DOAJ Directory of Open Access Journals</source><source>Alma/SFX Local Collection</source><creator>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</creator><creatorcontrib>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</creatorcontrib><description>Pb-Bi eutectic alloy has been receiving increasing attention as a heavy liquid metal coolant in accelerator driven systems and Generation IV fission reactors. Compatibility of structural materials with liquid PbBi eutectic alloy at high temperature is one of the issues concerned. In the present study, corrosion tests of T91 steel in stagnant Pb-Bi eutectic alloy in saturated oxygen condition at 450 oC were carried out. After experiments, the thickness and compositional profile of the oxide layer on the specimen were analyzed using SEM and EDX. Analysis results show that the thickness of the oxide layer increases as the exposure time increases from 500 h to 1,000 h. The thickness of the oxide layer remains almost unchanged at 15 to 16 mm from 1,000 to 1,500 h. Formation of a thick and protective oxide layer at 450 oC prevents the penetration of liquid Pb-Bi eutectic alloy into the matrix of the T91 steel.</description><identifier>ISSN: 1672-6421</identifier><identifier>EISSN: 2365-9459</identifier><language>eng</language><ispartof>中国铸造:英文版, 2014 (3), p.197-200</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/60073X/60073X.jpg</thumbnail><link.rule.ids>314,780,784,4024</link.rule.ids></links><search><creatorcontrib>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</creatorcontrib><title>Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450</title><title>中国铸造:英文版</title><addtitle>China Foundry</addtitle><description>Pb-Bi eutectic alloy has been receiving increasing attention as a heavy liquid metal coolant in accelerator driven systems and Generation IV fission reactors. Compatibility of structural materials with liquid PbBi eutectic alloy at high temperature is one of the issues concerned. In the present study, corrosion tests of T91 steel in stagnant Pb-Bi eutectic alloy in saturated oxygen condition at 450 oC were carried out. After experiments, the thickness and compositional profile of the oxide layer on the specimen were analyzed using SEM and EDX. Analysis results show that the thickness of the oxide layer increases as the exposure time increases from 500 h to 1,000 h. The thickness of the oxide layer remains almost unchanged at 15 to 16 mm from 1,000 to 1,500 h. Formation of a thick and protective oxide layer at 450 oC prevents the penetration of liquid Pb-Bi eutectic alloy into the matrix of the T91 steel.</description><issn>1672-6421</issn><issn>2365-9459</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqNyjEOgjAUgOHGaCJR7vA8AElLaZUVonF0YCcFCzxTKNASw-118AD-y7f8GxLEXIooTUS6JQGT5ziSScz2JHTuRb_Ji6RSBCTLbT8qjxUa9CvYBoqUgfNaG3ij78DgtOATHlWUIejF69pjDcoYu4LykAh6JLtGGafDnwdyul2L_B7VnR3aCYe2HGfs1byWgjIeM875P88Hf4M4sA</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>W92</scope><scope>~WA</scope></search><sort><creationdate>2014</creationdate><title>Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450</title><author>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-chongqing_primary_501321333</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</creatorcontrib><collection>中文科技期刊数据库</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库-工程技术</collection><collection>中文科技期刊数据库- 镜像站点</collection><jtitle>中国铸造:英文版</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Zhang Yutuo Dong Hong Wang Pei Ye Zhongfei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450</atitle><jtitle>中国铸造:英文版</jtitle><addtitle>China Foundry</addtitle><date>2014</date><risdate>2014</risdate><issue>3</issue><spage>197</spage><epage>200</epage><pages>197-200</pages><issn>1672-6421</issn><eissn>2365-9459</eissn><abstract>Pb-Bi eutectic alloy has been receiving increasing attention as a heavy liquid metal coolant in accelerator driven systems and Generation IV fission reactors. Compatibility of structural materials with liquid PbBi eutectic alloy at high temperature is one of the issues concerned. In the present study, corrosion tests of T91 steel in stagnant Pb-Bi eutectic alloy in saturated oxygen condition at 450 oC were carried out. After experiments, the thickness and compositional profile of the oxide layer on the specimen were analyzed using SEM and EDX. Analysis results show that the thickness of the oxide layer increases as the exposure time increases from 500 h to 1,000 h. The thickness of the oxide layer remains almost unchanged at 15 to 16 mm from 1,000 to 1,500 h. Formation of a thick and protective oxide layer at 450 oC prevents the penetration of liquid Pb-Bi eutectic alloy into the matrix of the T91 steel.</abstract></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1672-6421 |
ispartof | 中国铸造:英文版, 2014 (3), p.197-200 |
issn | 1672-6421 2365-9459 |
language | eng |
recordid | cdi_chongqing_primary_50132133 |
source | DOAJ Directory of Open Access Journals; Alma/SFX Local Collection |
title | Compatibility of T91 steel with liquid Pb-Bi eutectic alloy at 450 |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-21T08%3A08%3A23IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-chongqing&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Compatibility%20of%20T91%20steel%20with%20liquid%20Pb-Bi%20eutectic%20alloy%20at%20450&rft.jtitle=%E4%B8%AD%E5%9B%BD%E9%93%B8%E9%80%A0%EF%BC%9A%E8%8B%B1%E6%96%87%E7%89%88&rft.au=Zhang%20Yutuo%20Dong%20Hong%20Wang%20Pei%20Ye%20Zhongfei&rft.date=2014&rft.issue=3&rft.spage=197&rft.epage=200&rft.pages=197-200&rft.issn=1672-6421&rft.eissn=2365-9459&rft_id=info:doi/&rft_dat=%3Cchongqing%3E50132133%3C/chongqing%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_cqvip_id=50132133&rfr_iscdi=true |