Response mechanism of platinum electrode to uncoupled ions(Ⅰ)——Response of platinum electrode to Pb2+,Cd2+,Ca2+ and Mg2
The transient response mechanism of the platinum electrode to the uncoupled ions may be interpreted with the mixed phase formation (MPF) model of the transient response of precipitate-based ion-selective electrodes to interfering tons for Kxy<<1 It is discovered that the peak height of...
Gespeichert in:
Veröffentlicht in: | 中国科学:化学英文版 1997 (1), p.37-44 |
---|---|
1. Verfasser: | |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
Zusammenfassung: | The transient response mechanism of the platinum electrode to the uncoupled ions may be interpreted with the mixed phase formation (MPF) model of the transient response of precipitate-based ion-selective electrodes to interfering tons for Kxy<<1 It is discovered that the peak height of the transient signal is related to the solubility of M(OH)2 and hydration heat of M2+ The relation between the positive peak height of transient signal of Pb2+ or Cd2+ and lgaM obey tne Nernst equation,while that of Ca2+ or Mg2+ does not.The equilibrium potential is not of Nernst response for all ions. |
---|---|
ISSN: | 1674-7291 1869-1870 |