Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem

The paper presents the concept of energy-active segments construction of steel halls covered with a structure with a tie which contain solar radiation energy absorbers (SE). The following factors were taken into account: 1) slope exceeding 20%, which enables self-clearance of snow from the cover sur...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Budownictwo i Architektura 2014, Vol.13 (3), p.243-250
Hauptverfasser: Kowal, Zbigniew, Piotrowski, Rafał
Format: Artikel
Sprache:eng ; pol
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 250
container_issue 3
container_start_page 243
container_title Budownictwo i Architektura
container_volume 13
creator Kowal, Zbigniew
Piotrowski, Rafał
description The paper presents the concept of energy-active segments construction of steel halls covered with a structure with a tie which contain solar radiation energy absorbers (SE). The following factors were taken into account: 1) slope exceeding 20%, which enables self-clearance of snow from the cover surface and facilitates obtaining energy in the winter period; 2) reducing the width of energy-active expansion segments to 6x3=18m; 3) reducing thermal impact on internal forces and displacements of the structure elements; 4) parallel coupling of the structure elements to maintain load bearing capacity and reliability [2] above these recommended for RC2 class [3]; 5) dividing the cover structure into geometrically invariable assembly segments of the hall, which ensures safe and efficient assembly.
format Article
fullrecord <record><control><sourceid>ceeol</sourceid><recordid>TN_cdi_ceeol_journals_905473</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ceeol_id>905473</ceeol_id><sourcerecordid>905473</sourcerecordid><originalsourceid>FETCH-ceeol_journals_9054733</originalsourceid><addsrcrecordid>eNqFi0EKgkAYRocoSKobtJgDJIyOOrqOom3QXn7GX1MnlZmRsH2n6Dp1r1y4DFp98N77ZsTxwyBwuS_COXG8OElcFkXhkmyMqRhjviciLmKHnA8N6qKF2g73BqnB4oaNpdmgwIIcqpFdQdFOP7DWgx0Lq_va9hqoxqJXoBugD6Sflyzfz6LE25osclAGN9OuyPZ4uOxPrkRsVVq1_XhRJk1YGAjO_-rdTw3allJhmrVyStMuy_kX0W5PHA</addsrcrecordid><sourcetype>Enrichment Source</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem</title><source>DOAJ Directory of Open Access Journals</source><source>EZB-FREE-00999 freely available EZB journals</source><creator>Kowal, Zbigniew ; Piotrowski, Rafał</creator><creatorcontrib>Kowal, Zbigniew ; Piotrowski, Rafał</creatorcontrib><description>The paper presents the concept of energy-active segments construction of steel halls covered with a structure with a tie which contain solar radiation energy absorbers (SE). The following factors were taken into account: 1) slope exceeding 20%, which enables self-clearance of snow from the cover surface and facilitates obtaining energy in the winter period; 2) reducing the width of energy-active expansion segments to 6x3=18m; 3) reducing thermal impact on internal forces and displacements of the structure elements; 4) parallel coupling of the structure elements to maintain load bearing capacity and reliability [2] above these recommended for RC2 class [3]; 5) dividing the cover structure into geometrically invariable assembly segments of the hall, which ensures safe and efficient assembly.</description><identifier>ISSN: 1899-0665</identifier><identifier>EISSN: 2544-3275</identifier><language>eng ; pol</language><publisher>Lublin University of Technology Library</publisher><subject>Architecture ; Geography, Regional studies</subject><ispartof>Budownictwo i Architektura, 2014, Vol.13 (3), p.243-250</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.ceeol.com//api/image/getissuecoverimage?id=picture_2014_57179.jpg</thumbnail><link.rule.ids>314,776,780,4010</link.rule.ids></links><search><creatorcontrib>Kowal, Zbigniew</creatorcontrib><creatorcontrib>Piotrowski, Rafał</creatorcontrib><title>Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem</title><title>Budownictwo i Architektura</title><addtitle>Civil Engineering and Architecture</addtitle><description>The paper presents the concept of energy-active segments construction of steel halls covered with a structure with a tie which contain solar radiation energy absorbers (SE). The following factors were taken into account: 1) slope exceeding 20%, which enables self-clearance of snow from the cover surface and facilitates obtaining energy in the winter period; 2) reducing the width of energy-active expansion segments to 6x3=18m; 3) reducing thermal impact on internal forces and displacements of the structure elements; 4) parallel coupling of the structure elements to maintain load bearing capacity and reliability [2] above these recommended for RC2 class [3]; 5) dividing the cover structure into geometrically invariable assembly segments of the hall, which ensures safe and efficient assembly.</description><subject>Architecture</subject><subject>Geography, Regional studies</subject><issn>1899-0665</issn><issn>2544-3275</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><sourceid>REL</sourceid><recordid>eNqFi0EKgkAYRocoSKobtJgDJIyOOrqOom3QXn7GX1MnlZmRsH2n6Dp1r1y4DFp98N77ZsTxwyBwuS_COXG8OElcFkXhkmyMqRhjviciLmKHnA8N6qKF2g73BqnB4oaNpdmgwIIcqpFdQdFOP7DWgx0Lq_va9hqoxqJXoBugD6Sflyzfz6LE25osclAGN9OuyPZ4uOxPrkRsVVq1_XhRJk1YGAjO_-rdTw3allJhmrVyStMuy_kX0W5PHA</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Kowal, Zbigniew</creator><creator>Piotrowski, Rafał</creator><general>Lublin University of Technology Library</general><general>Biblioteka Politechniki Lubelskiej</general><scope>AE2</scope><scope>BIXPP</scope><scope>REL</scope></search><sort><creationdate>2014</creationdate><title>Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem</title><author>Kowal, Zbigniew ; Piotrowski, Rafał</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ceeol_journals_9054733</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng ; pol</language><creationdate>2014</creationdate><topic>Architecture</topic><topic>Geography, Regional studies</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kowal, Zbigniew</creatorcontrib><creatorcontrib>Piotrowski, Rafał</creatorcontrib><collection>Central and Eastern European Online Library (C.E.E.O.L.) (DFG Nationallizenzen)</collection><collection>CEEOL: Open Access</collection><collection>Central and Eastern European Online Library</collection><jtitle>Budownictwo i Architektura</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kowal, Zbigniew</au><au>Piotrowski, Rafał</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem</atitle><jtitle>Budownictwo i Architektura</jtitle><addtitle>Civil Engineering and Architecture</addtitle><date>2014</date><risdate>2014</risdate><volume>13</volume><issue>3</issue><spage>243</spage><epage>250</epage><pages>243-250</pages><issn>1899-0665</issn><eissn>2544-3275</eissn><abstract>The paper presents the concept of energy-active segments construction of steel halls covered with a structure with a tie which contain solar radiation energy absorbers (SE). The following factors were taken into account: 1) slope exceeding 20%, which enables self-clearance of snow from the cover surface and facilitates obtaining energy in the winter period; 2) reducing the width of energy-active expansion segments to 6x3=18m; 3) reducing thermal impact on internal forces and displacements of the structure elements; 4) parallel coupling of the structure elements to maintain load bearing capacity and reliability [2] above these recommended for RC2 class [3]; 5) dividing the cover structure into geometrically invariable assembly segments of the hall, which ensures safe and efficient assembly.</abstract><pub>Lublin University of Technology Library</pub><tpages>8</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1899-0665
ispartof Budownictwo i Architektura, 2014, Vol.13 (3), p.243-250
issn 1899-0665
2544-3275
language eng ; pol
recordid cdi_ceeol_journals_905473
source DOAJ Directory of Open Access Journals; EZB-FREE-00999 freely available EZB journals
subjects Architecture
Geography, Regional studies
title Energoaktywne segment dylatacyjne hal przekryte struktura regularna ze ściągiem
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-04T11%3A39%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ceeol&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Energoaktywne%20segment%20dylatacyjne%20hal%20przekryte%20struktura%20regularna%20ze%20%C5%9Bci%C4%85giem&rft.jtitle=Budownictwo%20i%20Architektura&rft.au=Kowal,%20Zbigniew&rft.date=2014&rft.volume=13&rft.issue=3&rft.spage=243&rft.epage=250&rft.pages=243-250&rft.issn=1899-0665&rft.eissn=2544-3275&rft_id=info:doi/&rft_dat=%3Cceeol%3E905473%3C/ceeol%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ceeol_id=905473&rfr_iscdi=true