Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study

Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study res...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:Medical Science Pulse 2019, Vol.13 (4), p.27-31
Hauptverfasser: Gładysz, Iwona, Wójtowicz-Bobin, Małgorzata, Sikora, Agnieszka, Karczewska, Zofia M, Karczewski, Jan
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page 31
container_issue 4
container_start_page 27
container_title Medical Science Pulse
container_volume 13
creator Gładysz, Iwona
Wójtowicz-Bobin, Małgorzata
Sikora, Agnieszka
Karczewska, Zofia M
Karczewski, Jan
description Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study results indicating the presence of Legionella spp. in Poland between 2009-2013 and 2014-2016. This study is a comparative retrospective epidemiological analysis of individual tests for the presence of Legionella spp. in hotels between two different time periods. The two time periods being compared in this study are between 2009-2013 (n=369 hotels) and 2014-2016 (n=174 hotels). Reporting has been performed in accordance with the STROBE checklist. Material and methods: Hot water samples were collected by employees of the Sanitary and Epidemiological Station in Poland as part of routine water quality monitoring. Samples were taken from the water supply systems of 369 hotels, representing 19.59% of total hotels in Poland, from January 2009 until December 2013. Samples were taken from the water supply systems of 174 hotels, representing 7.51% of total hotels in Poland, from January 2014 until December 2016. Results: The percentage of facilities classified as Group I remained comparable for the period between 2009 and 2013 compared to the period between 2014 and 2016. The percentage of facilities classified as Group II, however, showed a clear upward trend between 2014 and 2016 compared to the time period between 2009 and 2013. The percentage of facilities classified as Group III showed a clear downward trend between 2014 and 2016 compared to the time period between 2009 and 2013. Conclusions: The colonization rates observed in this comparative study indicate that the aquatic environment in these facilities requires constant monitoring to lower the risk of legionellosis. The increased colonization of hotel water networks with Legionella spp. is a serious health problem that requires constant monitoring.
format Article
fullrecord <record><control><sourceid>ceeol</sourceid><recordid>TN_cdi_ceeol_journals_832060</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><ceeol_id>832060</ceeol_id><sourcerecordid>832060</sourcerecordid><originalsourceid>FETCH-ceeol_journals_8320603</originalsourceid><addsrcrecordid>eNqFib0KwjAURoMoWLRv4HBfoHKb_uoqioOgg3uJ6a1tiUlJWsW3V0Fnp_Od74yYx5M4DsKU4_i3kySfMt-5FhF5lmY8ij0mj1IO1pKWBKaCA10bo0kpAa7rltBoOBnVuBpq05NycKH-QaSBI64CjmEEQpdvC-OPpWsQIM2tE1b0zZ3A9UP5nLNJJZQj_8sZW-y2580-kERGFa0ZrH7_RR5xTDH6k1_GsT89</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study</title><source>DOAJ Directory of Open Access Journals</source><source>Alma/SFX Local Collection</source><creator>Gładysz, Iwona ; Wójtowicz-Bobin, Małgorzata ; Sikora, Agnieszka ; Karczewska, Zofia M ; Karczewski, Jan</creator><creatorcontrib>Gładysz, Iwona ; Wójtowicz-Bobin, Małgorzata ; Sikora, Agnieszka ; Karczewska, Zofia M ; Karczewski, Jan</creatorcontrib><description>Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study results indicating the presence of Legionella spp. in Poland between 2009-2013 and 2014-2016. This study is a comparative retrospective epidemiological analysis of individual tests for the presence of Legionella spp. in hotels between two different time periods. The two time periods being compared in this study are between 2009-2013 (n=369 hotels) and 2014-2016 (n=174 hotels). Reporting has been performed in accordance with the STROBE checklist. Material and methods: Hot water samples were collected by employees of the Sanitary and Epidemiological Station in Poland as part of routine water quality monitoring. Samples were taken from the water supply systems of 369 hotels, representing 19.59% of total hotels in Poland, from January 2009 until December 2013. Samples were taken from the water supply systems of 174 hotels, representing 7.51% of total hotels in Poland, from January 2014 until December 2016. Results: The percentage of facilities classified as Group I remained comparable for the period between 2009 and 2013 compared to the period between 2014 and 2016. The percentage of facilities classified as Group II, however, showed a clear upward trend between 2014 and 2016 compared to the time period between 2009 and 2013. The percentage of facilities classified as Group III showed a clear downward trend between 2014 and 2016 compared to the time period between 2009 and 2013. Conclusions: The colonization rates observed in this comparative study indicate that the aquatic environment in these facilities requires constant monitoring to lower the risk of legionellosis. The increased colonization of hotel water networks with Legionella spp. is a serious health problem that requires constant monitoring.</description><identifier>ISSN: 2544-1558</identifier><identifier>EISSN: 2544-1620</identifier><language>eng</language><publisher>Opole Medical School</publisher><subject>Health and medicine and law</subject><ispartof>Medical Science Pulse, 2019, Vol.13 (4), p.27-31</ispartof><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttps://www.ceeol.com//api/image/getissuecoverimage?id=picture_2019_50894.jpg</thumbnail><link.rule.ids>314,777,781,4010</link.rule.ids></links><search><creatorcontrib>Gładysz, Iwona</creatorcontrib><creatorcontrib>Wójtowicz-Bobin, Małgorzata</creatorcontrib><creatorcontrib>Sikora, Agnieszka</creatorcontrib><creatorcontrib>Karczewska, Zofia M</creatorcontrib><creatorcontrib>Karczewski, Jan</creatorcontrib><title>Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study</title><title>Medical Science Pulse</title><addtitle>Medical Science Pulse</addtitle><description>Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study results indicating the presence of Legionella spp. in Poland between 2009-2013 and 2014-2016. This study is a comparative retrospective epidemiological analysis of individual tests for the presence of Legionella spp. in hotels between two different time periods. The two time periods being compared in this study are between 2009-2013 (n=369 hotels) and 2014-2016 (n=174 hotels). Reporting has been performed in accordance with the STROBE checklist. Material and methods: Hot water samples were collected by employees of the Sanitary and Epidemiological Station in Poland as part of routine water quality monitoring. Samples were taken from the water supply systems of 369 hotels, representing 19.59% of total hotels in Poland, from January 2009 until December 2013. Samples were taken from the water supply systems of 174 hotels, representing 7.51% of total hotels in Poland, from January 2014 until December 2016. Results: The percentage of facilities classified as Group I remained comparable for the period between 2009 and 2013 compared to the period between 2014 and 2016. The percentage of facilities classified as Group II, however, showed a clear upward trend between 2014 and 2016 compared to the time period between 2009 and 2013. The percentage of facilities classified as Group III showed a clear downward trend between 2014 and 2016 compared to the time period between 2009 and 2013. Conclusions: The colonization rates observed in this comparative study indicate that the aquatic environment in these facilities requires constant monitoring to lower the risk of legionellosis. The increased colonization of hotel water networks with Legionella spp. is a serious health problem that requires constant monitoring.</description><subject>Health and medicine and law</subject><issn>2544-1558</issn><issn>2544-1620</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><sourceid>REL</sourceid><recordid>eNqFib0KwjAURoMoWLRv4HBfoHKb_uoqioOgg3uJ6a1tiUlJWsW3V0Fnp_Od74yYx5M4DsKU4_i3kySfMt-5FhF5lmY8ij0mj1IO1pKWBKaCA10bo0kpAa7rltBoOBnVuBpq05NycKH-QaSBI64CjmEEQpdvC-OPpWsQIM2tE1b0zZ3A9UP5nLNJJZQj_8sZW-y2580-kERGFa0ZrH7_RR5xTDH6k1_GsT89</recordid><startdate>2019</startdate><enddate>2019</enddate><creator>Gładysz, Iwona</creator><creator>Wójtowicz-Bobin, Małgorzata</creator><creator>Sikora, Agnieszka</creator><creator>Karczewska, Zofia M</creator><creator>Karczewski, Jan</creator><general>Opole Medical School</general><general>Państwowa Medyczna Wyższa Szkoła Zawodowa w Opolu</general><scope>AE2</scope><scope>BIXPP</scope><scope>REL</scope></search><sort><creationdate>2019</creationdate><title>Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study</title><author>Gładysz, Iwona ; Wójtowicz-Bobin, Małgorzata ; Sikora, Agnieszka ; Karczewska, Zofia M ; Karczewski, Jan</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-ceeol_journals_8320603</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Health and medicine and law</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gładysz, Iwona</creatorcontrib><creatorcontrib>Wójtowicz-Bobin, Małgorzata</creatorcontrib><creatorcontrib>Sikora, Agnieszka</creatorcontrib><creatorcontrib>Karczewska, Zofia M</creatorcontrib><creatorcontrib>Karczewski, Jan</creatorcontrib><collection>Central and Eastern European Online Library (C.E.E.O.L.) (DFG Nationallizenzen)</collection><collection>CEEOL: Open Access</collection><collection>Central and Eastern European Online Library</collection><jtitle>Medical Science Pulse</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gładysz, Iwona</au><au>Wójtowicz-Bobin, Małgorzata</au><au>Sikora, Agnieszka</au><au>Karczewska, Zofia M</au><au>Karczewski, Jan</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study</atitle><jtitle>Medical Science Pulse</jtitle><addtitle>Medical Science Pulse</addtitle><date>2019</date><risdate>2019</risdate><volume>13</volume><issue>4</issue><spage>27</spage><epage>31</epage><pages>27-31</pages><issn>2544-1558</issn><eissn>2544-1620</eissn><abstract>Background: Legionella spp. have been found in both natural and manmade water systems, coastal waters, thermal waters, moist soils, clays, and near wastewater discharge sites. Aim of the study: This study aims to report a comparative, retrospective epidemiological analysis of water testing study results indicating the presence of Legionella spp. in Poland between 2009-2013 and 2014-2016. This study is a comparative retrospective epidemiological analysis of individual tests for the presence of Legionella spp. in hotels between two different time periods. The two time periods being compared in this study are between 2009-2013 (n=369 hotels) and 2014-2016 (n=174 hotels). Reporting has been performed in accordance with the STROBE checklist. Material and methods: Hot water samples were collected by employees of the Sanitary and Epidemiological Station in Poland as part of routine water quality monitoring. Samples were taken from the water supply systems of 369 hotels, representing 19.59% of total hotels in Poland, from January 2009 until December 2013. Samples were taken from the water supply systems of 174 hotels, representing 7.51% of total hotels in Poland, from January 2014 until December 2016. Results: The percentage of facilities classified as Group I remained comparable for the period between 2009 and 2013 compared to the period between 2014 and 2016. The percentage of facilities classified as Group II, however, showed a clear upward trend between 2014 and 2016 compared to the time period between 2009 and 2013. The percentage of facilities classified as Group III showed a clear downward trend between 2014 and 2016 compared to the time period between 2009 and 2013. Conclusions: The colonization rates observed in this comparative study indicate that the aquatic environment in these facilities requires constant monitoring to lower the risk of legionellosis. The increased colonization of hotel water networks with Legionella spp. is a serious health problem that requires constant monitoring.</abstract><pub>Opole Medical School</pub><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 2544-1558
ispartof Medical Science Pulse, 2019, Vol.13 (4), p.27-31
issn 2544-1558
2544-1620
language eng
recordid cdi_ceeol_journals_832060
source DOAJ Directory of Open Access Journals; Alma/SFX Local Collection
subjects Health and medicine and law
title Occurrence of Legionella spp. in Polish hotels between 2009-2013 and 2014-2016: a comparative study
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-19T10%3A37%3A45IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-ceeol&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Occurrence%20of%20Legionella%20spp.%20in%20Polish%20hotels%20between%202009-2013%20and%202014-2016:%20a%20comparative%20study&rft.jtitle=Medical%20Science%20Pulse&rft.au=G%C5%82adysz,%20Iwona&rft.date=2019&rft.volume=13&rft.issue=4&rft.spage=27&rft.epage=31&rft.pages=27-31&rft.issn=2544-1558&rft.eissn=2544-1620&rft_id=info:doi/&rft_dat=%3Cceeol%3E832060%3C/ceeol%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_id=info:pmid/&rft_ceeol_id=832060&rfr_iscdi=true