Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol

Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition-property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable...

Ausführliche Beschreibung

Gespeichert in:
Bibliographische Detailangaben
Veröffentlicht in:arXiv.org 2024-07
Hauptverfasser: Varner, Hannah, Cohen, Tal
Format: Artikel
Sprache:eng
Schlagworte:
Online-Zugang:Volltext
Tags: Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
container_end_page
container_issue
container_start_page
container_title arXiv.org
container_volume
creator Varner, Hannah
Cohen, Tal
description Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition-property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable results for stiff materials, for which they were originally developed. However, when applied to the characterization of soft and biological materials, the same cannot be said, and the spread of reported properties of similar materials is vast. Polydimethylsiloxane (PDMS), commonly obtained from Dow as SYLGARD 184, is a ubiquitous such material, which has been integral to the rapid development of biocompatible microfluidic devices and flexible electronics in recent decades. However, reported shear moduli of this material range over 2 orders of magnitude for similar chemical compositions. Taking advantage of the increased mechanical scrutiny afforded to SYLGARD 184 in recent years, we combine both published and new experimental data obtained using 9 mechanical test methods. A statistical analysis then elucidates the significant bias induced by the test method itself, and distinguishes this bias from the influence of curing protocols on the mechanical properties. The goal of this work is thus two-fold: (i) it provides a quantitative understanding of the different factors that influence reported properties of this particular material, and (ii) it serves as a cautionary tale. As researchers in the field of mechanics strive to quantify the properties of increasingly complex soft and biological materials, converging on a standardized measurement of PDMS is a necessary first step.
doi_str_mv 10.48550/arxiv.2404.16960
format Article
fullrecord <record><control><sourceid>proquest_arxiv</sourceid><recordid>TN_cdi_arxiv_primary_2404_16960</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3083738599</sourcerecordid><originalsourceid>FETCH-LOGICAL-a529-44afcfab20e7051968b9557f49998eac6742b07d52c27b60651b1fd099627ad83</originalsourceid><addsrcrecordid>eNotkF1LwzAYRoMgOOZ-gFcGvO5M8x3vZM4PmCi4-5Kmieto05qkMv-9mfPqvTnvw-EAcFWiJZWMoVsdDu33ElNElyVXHJ2BGSakLCTF-AIsYtwjhDAXmDEyA_36MHa69a3_hGlnYRyD1Q1sPeytjlOwvfUJDg6-P7x-QNvpmFoDxzCMNqTWxruMum6y3tgjlWxM-TPthgZq30AzheNy5tNghu4SnDvdRbv4v3OwfVxvV8_F5u3pZXW_KTTDqqBUO-N0jZEViJWKy1oxJhxVSkmrDRcU10g0DBssao44K-vSNUgpjoVuJJmD69PsX4tqDG2vw091bFL9NcnEzYnIZl9Tlq72wxR8dqoIkkQQyZQivwMtZQo</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>3083738599</pqid></control><display><type>article</type><title>Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol</title><source>arXiv.org</source><source>Free E- Journals</source><creator>Varner, Hannah ; Cohen, Tal</creator><creatorcontrib>Varner, Hannah ; Cohen, Tal</creatorcontrib><description>Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition-property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable results for stiff materials, for which they were originally developed. However, when applied to the characterization of soft and biological materials, the same cannot be said, and the spread of reported properties of similar materials is vast. Polydimethylsiloxane (PDMS), commonly obtained from Dow as SYLGARD 184, is a ubiquitous such material, which has been integral to the rapid development of biocompatible microfluidic devices and flexible electronics in recent decades. However, reported shear moduli of this material range over 2 orders of magnitude for similar chemical compositions. Taking advantage of the increased mechanical scrutiny afforded to SYLGARD 184 in recent years, we combine both published and new experimental data obtained using 9 mechanical test methods. A statistical analysis then elucidates the significant bias induced by the test method itself, and distinguishes this bias from the influence of curing protocols on the mechanical properties. The goal of this work is thus two-fold: (i) it provides a quantitative understanding of the different factors that influence reported properties of this particular material, and (ii) it serves as a cautionary tale. As researchers in the field of mechanics strive to quantify the properties of increasingly complex soft and biological materials, converging on a standardized measurement of PDMS is a necessary first step.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.2404.16960</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Bias ; Biocompatibility ; Biological effects ; Biological materials ; Biological properties ; Chemical composition ; Convergence ; Curing ; Elastic properties ; Flexible components ; Interrogation ; Mechanical properties ; Mechanical tests ; Microfluidic devices ; Nanoindentation ; Physics - Soft Condensed Matter ; Polydimethylsiloxane ; Shear modulus ; Statistical analysis ; Statistical methods ; Test methods</subject><ispartof>arXiv.org, 2024-07</ispartof><rights>2024. This work is published under http://creativecommons.org/licenses/by-nc-nd/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>http://creativecommons.org/licenses/by-nc-nd/4.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,781,785,886,27926</link.rule.ids><backlink>$$Uhttps://doi.org/10.48550/arXiv.2404.16960$$DView paper in arXiv$$Hfree_for_read</backlink><backlink>$$Uhttps://doi.org/10.1039/D4SM00573B$$DView published paper (Access to full text may be restricted)$$Hfree_for_read</backlink></links><search><creatorcontrib>Varner, Hannah</creatorcontrib><creatorcontrib>Cohen, Tal</creatorcontrib><title>Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol</title><title>arXiv.org</title><description>Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition-property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable results for stiff materials, for which they were originally developed. However, when applied to the characterization of soft and biological materials, the same cannot be said, and the spread of reported properties of similar materials is vast. Polydimethylsiloxane (PDMS), commonly obtained from Dow as SYLGARD 184, is a ubiquitous such material, which has been integral to the rapid development of biocompatible microfluidic devices and flexible electronics in recent decades. However, reported shear moduli of this material range over 2 orders of magnitude for similar chemical compositions. Taking advantage of the increased mechanical scrutiny afforded to SYLGARD 184 in recent years, we combine both published and new experimental data obtained using 9 mechanical test methods. A statistical analysis then elucidates the significant bias induced by the test method itself, and distinguishes this bias from the influence of curing protocols on the mechanical properties. The goal of this work is thus two-fold: (i) it provides a quantitative understanding of the different factors that influence reported properties of this particular material, and (ii) it serves as a cautionary tale. As researchers in the field of mechanics strive to quantify the properties of increasingly complex soft and biological materials, converging on a standardized measurement of PDMS is a necessary first step.</description><subject>Bias</subject><subject>Biocompatibility</subject><subject>Biological effects</subject><subject>Biological materials</subject><subject>Biological properties</subject><subject>Chemical composition</subject><subject>Convergence</subject><subject>Curing</subject><subject>Elastic properties</subject><subject>Flexible components</subject><subject>Interrogation</subject><subject>Mechanical properties</subject><subject>Mechanical tests</subject><subject>Microfluidic devices</subject><subject>Nanoindentation</subject><subject>Physics - Soft Condensed Matter</subject><subject>Polydimethylsiloxane</subject><subject>Shear modulus</subject><subject>Statistical analysis</subject><subject>Statistical methods</subject><subject>Test methods</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GOX</sourceid><recordid>eNotkF1LwzAYRoMgOOZ-gFcGvO5M8x3vZM4PmCi4-5Kmieto05qkMv-9mfPqvTnvw-EAcFWiJZWMoVsdDu33ElNElyVXHJ2BGSakLCTF-AIsYtwjhDAXmDEyA_36MHa69a3_hGlnYRyD1Q1sPeytjlOwvfUJDg6-P7x-QNvpmFoDxzCMNqTWxruMum6y3tgjlWxM-TPthgZq30AzheNy5tNghu4SnDvdRbv4v3OwfVxvV8_F5u3pZXW_KTTDqqBUO-N0jZEViJWKy1oxJhxVSkmrDRcU10g0DBssao44K-vSNUgpjoVuJJmD69PsX4tqDG2vw091bFL9NcnEzYnIZl9Tlq72wxR8dqoIkkQQyZQivwMtZQo</recordid><startdate>20240720</startdate><enddate>20240720</enddate><creator>Varner, Hannah</creator><creator>Cohen, Tal</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>GOX</scope></search><sort><creationdate>20240720</creationdate><title>Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol</title><author>Varner, Hannah ; Cohen, Tal</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a529-44afcfab20e7051968b9557f49998eac6742b07d52c27b60651b1fd099627ad83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>Bias</topic><topic>Biocompatibility</topic><topic>Biological effects</topic><topic>Biological materials</topic><topic>Biological properties</topic><topic>Chemical composition</topic><topic>Convergence</topic><topic>Curing</topic><topic>Elastic properties</topic><topic>Flexible components</topic><topic>Interrogation</topic><topic>Mechanical properties</topic><topic>Mechanical tests</topic><topic>Microfluidic devices</topic><topic>Nanoindentation</topic><topic>Physics - Soft Condensed Matter</topic><topic>Polydimethylsiloxane</topic><topic>Shear modulus</topic><topic>Statistical analysis</topic><topic>Statistical methods</topic><topic>Test methods</topic><toplevel>online_resources</toplevel><creatorcontrib>Varner, Hannah</creatorcontrib><creatorcontrib>Cohen, Tal</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science &amp; Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Publicly Available Content Database</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>arXiv.org</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Varner, Hannah</au><au>Cohen, Tal</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol</atitle><jtitle>arXiv.org</jtitle><date>2024-07-20</date><risdate>2024</risdate><eissn>2331-8422</eissn><abstract>Accuracy in the measurement of mechanical properties is essential for precision engineering and for the interrogation of composition-property relationships. Conventional methods of mechanical testing, such as uniaxial tension, compression, and nanoindentation, provide highly repeatable and reliable results for stiff materials, for which they were originally developed. However, when applied to the characterization of soft and biological materials, the same cannot be said, and the spread of reported properties of similar materials is vast. Polydimethylsiloxane (PDMS), commonly obtained from Dow as SYLGARD 184, is a ubiquitous such material, which has been integral to the rapid development of biocompatible microfluidic devices and flexible electronics in recent decades. However, reported shear moduli of this material range over 2 orders of magnitude for similar chemical compositions. Taking advantage of the increased mechanical scrutiny afforded to SYLGARD 184 in recent years, we combine both published and new experimental data obtained using 9 mechanical test methods. A statistical analysis then elucidates the significant bias induced by the test method itself, and distinguishes this bias from the influence of curing protocols on the mechanical properties. The goal of this work is thus two-fold: (i) it provides a quantitative understanding of the different factors that influence reported properties of this particular material, and (ii) it serves as a cautionary tale. As researchers in the field of mechanics strive to quantify the properties of increasingly complex soft and biological materials, converging on a standardized measurement of PDMS is a necessary first step.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.2404.16960</doi><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier EISSN: 2331-8422
ispartof arXiv.org, 2024-07
issn 2331-8422
language eng
recordid cdi_arxiv_primary_2404_16960
source arXiv.org; Free E- Journals
subjects Bias
Biocompatibility
Biological effects
Biological materials
Biological properties
Chemical composition
Convergence
Curing
Elastic properties
Flexible components
Interrogation
Mechanical properties
Mechanical tests
Microfluidic devices
Nanoindentation
Physics - Soft Condensed Matter
Polydimethylsiloxane
Shear modulus
Statistical analysis
Statistical methods
Test methods
title Explaining the spread in measurement of PDMS elastic properties: influence of test method and curing protocol
url https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-18T13%3A45%3A29IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_arxiv&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Explaining%20the%20spread%20in%20measurement%20of%20PDMS%20elastic%20properties:%20influence%20of%20test%20method%20and%20curing%20protocol&rft.jtitle=arXiv.org&rft.au=Varner,%20Hannah&rft.date=2024-07-20&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.2404.16960&rft_dat=%3Cproquest_arxiv%3E3083738599%3C/proquest_arxiv%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=3083738599&rft_id=info:pmid/&rfr_iscdi=true