Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)
Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be a...
Gespeichert in:
Veröffentlicht in: | arXiv.org 2023-10 |
---|---|
Hauptverfasser: | , , , , , |
Format: | Artikel |
Sprache: | eng |
Schlagworte: | |
Online-Zugang: | Volltext |
Tags: |
Tag hinzufügen
Keine Tags, Fügen Sie den ersten Tag hinzu!
|
container_end_page | |
---|---|
container_issue | |
container_start_page | |
container_title | arXiv.org |
container_volume | |
creator | Hardy, Erwan Poree, Jonathan Belgharbi, Hatim Bourquin, Chloe Lesage, Frederic Provost, Jean |
description | Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping. |
doi_str_mv | 10.48550/arxiv.2310.13117 |
format | Article |
fullrecord | <record><control><sourceid>proquest_arxiv</sourceid><recordid>TN_cdi_arxiv_primary_2310_13117</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>2880585999</sourcerecordid><originalsourceid>FETCH-LOGICAL-a529-7005b72b0166340abf0585719346421f34a32d43232a9f0a017b9924b788f6c13</originalsourceid><addsrcrecordid>eNotj11LwzAYhYMgOOZ-gFcGvNGLzuRN0iSXY8wPnCh2Xpe3XasdbVOTVZy_3m7z6sDhcM55CLngbCqNUuwW_U_1PQUxGFxwrk_ICITgkZEAZ2QSwoYxBrEGpcSIPCUd-lDQ_BPbtqhpwKarq_aDls7Tvt56DK5v17R2OdbVL24r19Kmyr0Luet29Dp5nb0li-h9-XxzTk5LrEMx-dcxWd0tVvOHaPly_zifLSNUYCPNmMo0ZIzHsZAMs5IpozS3QsYSeCkkClhLAQLQlgwZ15m1IDNtTBnnXIzJ5bH2QJp2vmrQ79I9cXogHhJXx0Tn3VdfhG26cb1vh08pGLOfs9aKP1VwVpI</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>2880585999</pqid></control><display><type>article</type><title>Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)</title><source>Freely Accessible Journals</source><source>arXiv.org</source><creator>Hardy, Erwan ; Poree, Jonathan ; Belgharbi, Hatim ; Bourquin, Chloe ; Lesage, Frederic ; Provost, Jean</creator><creatorcontrib>Hardy, Erwan ; Poree, Jonathan ; Belgharbi, Hatim ; Bourquin, Chloe ; Lesage, Frederic ; Provost, Jean</creatorcontrib><description>Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping.</description><identifier>EISSN: 2331-8422</identifier><identifier>DOI: 10.48550/arxiv.2310.13117</identifier><language>eng</language><publisher>Ithaca: Cornell University Library, arXiv.org</publisher><subject>Channels ; Data acquisition ; Frames per second ; Localization ; Mapping ; Microscopy ; Optimization ; Performance evaluation ; Physics - Medical Physics ; Signal to noise ratio ; Ultrasonic imaging</subject><ispartof>arXiv.org, 2023-10</ispartof><rights>2023. This work is published under http://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.</rights><rights>http://creativecommons.org/licenses/by/4.0</rights><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>228,230,782,786,887,27932</link.rule.ids><backlink>$$Uhttps://doi.org/10.1088/1361-6560/abf1b6$$DView published paper (Access to full text may be restricted)$$Hfree_for_read</backlink><backlink>$$Uhttps://doi.org/10.48550/arXiv.2310.13117$$DView paper in arXiv$$Hfree_for_read</backlink></links><search><creatorcontrib>Hardy, Erwan</creatorcontrib><creatorcontrib>Poree, Jonathan</creatorcontrib><creatorcontrib>Belgharbi, Hatim</creatorcontrib><creatorcontrib>Bourquin, Chloe</creatorcontrib><creatorcontrib>Lesage, Frederic</creatorcontrib><creatorcontrib>Provost, Jean</creatorcontrib><title>Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)</title><title>arXiv.org</title><description>Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping.</description><subject>Channels</subject><subject>Data acquisition</subject><subject>Frames per second</subject><subject>Localization</subject><subject>Mapping</subject><subject>Microscopy</subject><subject>Optimization</subject><subject>Performance evaluation</subject><subject>Physics - Medical Physics</subject><subject>Signal to noise ratio</subject><subject>Ultrasonic imaging</subject><issn>2331-8422</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><sourceid>ABUWG</sourceid><sourceid>AFKRA</sourceid><sourceid>AZQEC</sourceid><sourceid>BENPR</sourceid><sourceid>CCPQU</sourceid><sourceid>DWQXO</sourceid><sourceid>GOX</sourceid><recordid>eNotj11LwzAYhYMgOOZ-gFcGvNGLzuRN0iSXY8wPnCh2Xpe3XasdbVOTVZy_3m7z6sDhcM55CLngbCqNUuwW_U_1PQUxGFxwrk_ICITgkZEAZ2QSwoYxBrEGpcSIPCUd-lDQ_BPbtqhpwKarq_aDls7Tvt56DK5v17R2OdbVL24r19Kmyr0Luet29Dp5nb0li-h9-XxzTk5LrEMx-dcxWd0tVvOHaPly_zifLSNUYCPNmMo0ZIzHsZAMs5IpozS3QsYSeCkkClhLAQLQlgwZ15m1IDNtTBnnXIzJ5bH2QJp2vmrQ79I9cXogHhJXx0Tn3VdfhG26cb1vh08pGLOfs9aKP1VwVpI</recordid><startdate>20231019</startdate><enddate>20231019</enddate><creator>Hardy, Erwan</creator><creator>Poree, Jonathan</creator><creator>Belgharbi, Hatim</creator><creator>Bourquin, Chloe</creator><creator>Lesage, Frederic</creator><creator>Provost, Jean</creator><general>Cornell University Library, arXiv.org</general><scope>8FE</scope><scope>8FG</scope><scope>ABJCF</scope><scope>ABUWG</scope><scope>AFKRA</scope><scope>AZQEC</scope><scope>BENPR</scope><scope>BGLVJ</scope><scope>CCPQU</scope><scope>DWQXO</scope><scope>HCIFZ</scope><scope>L6V</scope><scope>M7S</scope><scope>PIMPY</scope><scope>PQEST</scope><scope>PQQKQ</scope><scope>PQUKI</scope><scope>PRINS</scope><scope>PTHSS</scope><scope>GOX</scope></search><sort><creationdate>20231019</creationdate><title>Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)</title><author>Hardy, Erwan ; Poree, Jonathan ; Belgharbi, Hatim ; Bourquin, Chloe ; Lesage, Frederic ; Provost, Jean</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-a529-7005b72b0166340abf0585719346421f34a32d43232a9f0a017b9924b788f6c13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Channels</topic><topic>Data acquisition</topic><topic>Frames per second</topic><topic>Localization</topic><topic>Mapping</topic><topic>Microscopy</topic><topic>Optimization</topic><topic>Performance evaluation</topic><topic>Physics - Medical Physics</topic><topic>Signal to noise ratio</topic><topic>Ultrasonic imaging</topic><toplevel>online_resources</toplevel><creatorcontrib>Hardy, Erwan</creatorcontrib><creatorcontrib>Poree, Jonathan</creatorcontrib><creatorcontrib>Belgharbi, Hatim</creatorcontrib><creatorcontrib>Bourquin, Chloe</creatorcontrib><creatorcontrib>Lesage, Frederic</creatorcontrib><creatorcontrib>Provost, Jean</creatorcontrib><collection>ProQuest SciTech Collection</collection><collection>ProQuest Technology Collection</collection><collection>Materials Science & Engineering Collection</collection><collection>ProQuest Central (Alumni Edition)</collection><collection>ProQuest Central UK/Ireland</collection><collection>ProQuest Central Essentials</collection><collection>ProQuest Central</collection><collection>Technology Collection</collection><collection>ProQuest One Community College</collection><collection>ProQuest Central Korea</collection><collection>SciTech Premium Collection</collection><collection>ProQuest Engineering Collection</collection><collection>Engineering Database</collection><collection>Access via ProQuest (Open Access)</collection><collection>ProQuest One Academic Eastern Edition (DO NOT USE)</collection><collection>ProQuest One Academic</collection><collection>ProQuest One Academic UKI Edition</collection><collection>ProQuest Central China</collection><collection>Engineering Collection</collection><collection>arXiv.org</collection><jtitle>arXiv.org</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Hardy, Erwan</au><au>Poree, Jonathan</au><au>Belgharbi, Hatim</au><au>Bourquin, Chloe</au><au>Lesage, Frederic</au><au>Provost, Jean</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM)</atitle><jtitle>arXiv.org</jtitle><date>2023-10-19</date><risdate>2023</risdate><eissn>2331-8422</eissn><abstract>Ultrasound Localization Microscopy (ULM) has recently enabled the mapping of the cerebral vasculature in vivo with a resolution ten times smaller than the wavelength used, down to ten microns. However, with frame rates up to 20.000 frames per second, this method requires large amount of data to be acquired, transmitted, stored, and processed. The transfer rate is, as of today, one of the main limiting factors of this technology. Herein, we introduce a novel reconstruction framework to decrease this quantity of data to be acquired and the complexity of the required hardware by randomly subsampling the channels of a linear probe. Method performance evaluation as well as parameters optimization were conducted in silico using the SIMUS simulation software in an anatomically realistic phantom and then compared to in vivo acquisitions in a rat brain after craniotomy. Results show that reducing the number of active elements deteriorates the signal-to-noise ratio and could lead to false microbubbles detections but has limited effect on localization accuracy. In simulation, the false positive rate on microbubble detection deteriorates from 3.7% for 128 channels in receive and 7 steered angles to 11% for 16 channels and 7 angles. The average localization accuracy ranges from 10.6 um and 9.93 um for 16 channels/3 angles and 128 channels/13 angles respectively. These results suggest that a compromise can be found between the number of channels and the quality of the reconstructed vascular network and demonstrate feasibility of performing ULM with a reduced number of channels in receive, paving the way for low-cost devices enabling high-resolution vascular mapping.</abstract><cop>Ithaca</cop><pub>Cornell University Library, arXiv.org</pub><doi>10.48550/arxiv.2310.13117</doi><oa>free_for_read</oa></addata></record> |
fulltext | fulltext |
identifier | EISSN: 2331-8422 |
ispartof | arXiv.org, 2023-10 |
issn | 2331-8422 |
language | eng |
recordid | cdi_arxiv_primary_2310_13117 |
source | Freely Accessible Journals; arXiv.org |
subjects | Channels Data acquisition Frames per second Localization Mapping Microscopy Optimization Performance evaluation Physics - Medical Physics Signal to noise ratio Ultrasonic imaging |
title | Sparse channel sampling for ultrasound localization microscopy (SPARSE-ULM) |
url | https://sfx.bib-bvb.de/sfx_tum?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-04T14%3A20%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_arxiv&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Sparse%20channel%20sampling%20for%20ultrasound%20localization%20microscopy%20(SPARSE-ULM)&rft.jtitle=arXiv.org&rft.au=Hardy,%20Erwan&rft.date=2023-10-19&rft.eissn=2331-8422&rft_id=info:doi/10.48550/arxiv.2310.13117&rft_dat=%3Cproquest_arxiv%3E2880585999%3C/proquest_arxiv%3E%3Curl%3E%3C/url%3E&disable_directlink=true&sfx.directlink=off&sfx.report_link=0&rft_id=info:oai/&rft_pqid=2880585999&rft_id=info:pmid/&rfr_iscdi=true |